13 resultados para ROTARY INSTRUMENTS
em Aston University Research Archive
Resumo:
360-degree feedback from a variety of rater sources yields important information about leaders' styles, strengths and weaknesses for development. Results where observer ratings are discrepant (i.e., different) from self-ratings are often seen as indicators of problematic leadership relationships, skills, or lack of self-awareness. Yet research into the antecedents of such self-observer rating discrepancy suggests the presence of systematic influences, such as cultural values. The present study investigates the variation of rating discrepancies on three leadership skills (decision making, leading employees, and composure) in dependence of one exemplary culture dimension (power distance) on data from 31 countries using multilevel structural equation modelling. Results show that cultural values indeed predict self-observer rating discrepancies. Thus, systemic and contextual influences such as culture need to be taken into consideration when interpreting the importance and meaning of self-observer rating discrepancies in 360-degree instruments.
Resumo:
BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.
Resumo:
The purpose of this investigation was to design a novel magnetic drive and bearing system for a new centrifugal rotary blood pump (CRBP). The drive system consists of two components: (i) permanent magnets within the impeller of the CRBP; and (ii) the driving electromagnets. Orientation of the magnets varies from axial through to 60° included out-lean (conical configuration). Permanent magnets replace the electromagnet drive to allow easier characterization. The performance characteristics tested were the axial force of attraction between the stator and rotor at angles of rotational alignment, Ø, and the corresponding torque at those angles. The drive components were tested for various magnetic cone angles, ?. The test was repeated for three backing conditions: (i) non-backed; (ii) steel-cupped; and (iii) steel plate back-iron, performed on an Instron tensile testing machine. Experimental results were expanded upon through finite element and boundary element analysis (BEM). The force/torque characteristics were maximal for a 12-magnet configuration at 0° cone angle with steel-back iron (axial force = 60 N, torque = 0.375 Nm). BEM showed how introducing a cone angle increases the radial restoring force threefold while not compromising axial bearing force. Magnets in the drive system may be orientated not only to provide adequate coupling to drive the CRBP, but to provide significant axial and radial bearing forces capable of withstanding over 100 m/s2 shock excitation on the impeller. Although the 12 magnet 0° (?) configuration yielded the greatest force/torque characteristic, this was seen as potentially unattractive as this magnetic cone angle yielded poor radial restoring force characteristics.
Resumo:
This thesis covers both experimental and computer investigations into the dynamic behaviour of mechanical seals. The literature survey shows no investigations on the effect of vibration on mechanical seals of the type common in the various process industries. Typical seal designs are discussed. A form of Reynolds' equation has been developed that permits the calculation of stiffnesses and damping coefficients for the fluid film. The dynamics of the mechanical seal floating ring have been investigated using approximate formulae, and it has been shown that the floating ring will behave as a rigid body. Some elements, such as the radial damping due to the fluid film, are small and may be neglected. The equations of motion of the floating ring have been developed utilising the significant elements, and a solution technique described. The stiffness and damping coefficients of nitrile rubber o-rings have been obtained. These show a wide variation, with a constant stiffness up to 60 Hz. The importance of the effect of temperature on the properties is discussed. An unsuccessful test rig is described in the appendices. The dynamic behaviour of a mechanical seal has been investigated experimentally, including the effect of changes of speed, sealed pressure and seal geometry. The results, as expected, show that high vibration levels result in both high leakage and seal temperatures. Computer programs have been developed to solve Reynolds' Equation and the equations of motion. Two solution techniques for this latter program were developed, the unsuccesful technique is described in the appendices. Some stability problems were encountered, but despite these the solution shows good agreement with some of the experimental conditions. Possible reasons for the discrepancies are discussed. Various suggestions for future work in this field are given. These include the combining of the programs and more extensive experimental and computer modelling.
Resumo:
Since the 1980s UK government enthusiasm for market reforms has reconfigured the nature and scope of public services. Initially the marketisation of public services changed how public services were provided, increasingly market reforms and pro business policies have also modified the formation and understanding of public policy problematics and how they ought to be resolved. This is particularly noticeable when markets work imperfectly or even fail. UK governments have shown their reluctance to employ regulatory instruments to change the behaviour of companies preferring instead to make use of softer interventions, by focusing on providing advice for consumers and urging individuals to act responsibly. The dilemmas of this approach are explored by discussing the UK's former Labour government's (1997–2010) response to the increase in the incidence of obesity and related health complications.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.
Resumo:
A method of accurately controlling the position of a mobile robot using an external large volume metrology (LVM) instrument is presented in this article. By utilising an LVM instrument such as a laser tracker or indoor GPS (iGPS) in mobile robot navigation, many of the most difficult problems in mobile robot navigation can be simplified or avoided. Using the real-time position information from the laser tracker, a very simple navigation algorithm, and a low cost robot, 5mm repeatability was achieved over a volume of 30m radius. A surface digitisation scan of a wind turbine blade section was also demonstrated, illustrating possible applications of the method for manufacturing processes. Further, iGPS guidance of a small KUKA omni-directional robot has been demonstrated, and a full scale prototype system is being developed in cooperation with KUKA Robotics, UK. © 2011 Taylor & Francis.
Resumo:
This paper shows how the angular uncertainties can be determined for a rotary-laser automatic theodolite of the type used in (indoor-GPS) iGPS networks. Initially, the fundamental physics of the rotating head device is used to propagate uncertainties using Monte Carlo simulation. This theoretical element of the study shows how the angular uncertainty is affected by internal parameters, the actual values of which are estimated. Experiments are then carried out to determine the actual uncertainty in the azimuth angle. Results are presented that show that uncertainty decreases with sampling duration. Other significant findings are that uncertainty is relatively constant throughout the working volume and that the uncertainty value is not dependent on the size of the reference angle. © 2009 IMechE.
Resumo:
Measurement and verification of products and processes during the early design is attracting increasing interest from high value manufacturing industries. Measurement planning is deemed as an effective means to facilitate the integration of the metrology activity into a wider range of production processes. However, the literature reveals that there are very few research efforts in this field, especially regarding large volume metrology. This paper presents a novel approach to accomplish instruments selection, the first stage of measurement planning process, by mapping measurability characteristics between specific measurement assignments and instruments.