11 resultados para REVERSAL

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The visual evoked magnetic response to half-field stimulation using pattern reversal was studied using a d.c. SQUID coupled to a second order gradiometer. The main component of the magnetic response consisted of a positive wave at around 100 ms (P100M). At the time this component was present the response to half-field stimulation consisted of an outgoing magnetic field contralateral and extending to the midline. When the left half field was stimulated the outgoing field was over the posterior right visual cortex and when the right half field was stimulated it was over the left anterior visual cortex. These findings would correctly identify a source located in the contralateral visual cortex. The orientation of the dipoles was not that previously assumed to explain the paradoxical lateralization of the visual evoked potential. The results are discussed in terms of both electrical and magnetic models of the calcarine fissure. © 1992.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The topography of the visual evoked magnetic response (VEMR) to pattern reversal stimulation was studied in four normal subjects using a single channel BTI magnetometer. VEMRs were recorded from 20 locations over the occipital scalp and the topographic distribution of the most consistent component (P100M) studied. A single dipole in a sphere model was fitted to the data. Topographic maps were similar when recorded two months apart on the same subject to the same stimulus. Half field (HF) stimulation elicited responses from sources on the medial surface of the calcarine fissure mainly in the contralateral hemisphere as predicted by the cruciform model. The full field (FF) responses to large checks were approximately the sum of the HF responses. However, with small checks, FF stimulation appeared to activate a different combination of sources than the two HFs. In addition, HF topography was more consistent between subjects than FF for small check sizes. Topographic studies of the VEMR may help to explain the analogous visual evoked electrical response and will be essential to define optimal recording positions for clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The visual evoked magnetic response to half-field stimulation using pattern reversal was studied using a dc-SQUID coupled to a second-order gradiometer. The main component of the magnetic response consisted of a positive wave at around 100ms (P100M). At the same time this component was present the reponse to half-field stimulation consisted of an outgoing field contralateral and extending to the midline. When the left half-field was stimulates the outgoing field was over the posterior right visual cortex and when the right half field was stimulated it was over the left anterior visual cortex. These findings would correltly identify a source located in the contralateral visual cortex. The orientation of the dipoles was not that previously assumed to explain the paradoxical lateralization of the visual evoked potential. The results are discussed in terms of both electrical and magnetic models of the calcarine fissure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have attempted to establish normative values of components of the magnetic evoked field to flash and pattern reversal stimuli prior to clinical use of the MEG. Full visual field, binocular evoked magnetic fields were recorded from 100 subjects 16 to 86 years of age with a single channel dc Squid (BTI) second-order gradiometer at a point 5-6cm above the inion. The majority of subjects showed a large positive component (out going magnetic field) of mean latency 115 ms (SD range 2.5 -11.8 in different decades of life) to the pattern reversal stimulus. In many subjects, this P100M was preceeded and succeeded by negative deflections (in going field). About 6% of subjects showed an inverted response i.e. a PNP wave. Waveforms to flash were more variable in shape with several positive components; the most consistent having a mean latency of 110ms (SD range 6.4-23.2). Responses to both stimuli were consistent when measured on the same subject on six different occasions (SD range 4.8 to 7.3). The data suggest that norms can be established for evoked magnetic field components, in particular for the pattern reversal P100M, which could be used in the diagnosis of neuro-opthalmological disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blurring a pattern reversal stimulus increases the latency and decreases the amplitude of the visual evoked potential (VEP) P100 peak. Recording the visual evoked magnetic response (VEMR) is some subjects may therefore be difficult because their spectacles create excessive magnetic noise. Hence, the effect of varying degrees of blur (-5 to +5 D) on the VEMR was investigated in three subjects with 6/6 vision to determine whether refraction with non-magnetic frames and lenses was necessary before magnetic recording. Small (32') and larger (70') checks were studied since there is evidence that blurring small checks has a more significant effect on the VEP compared with large checks. The VEMR was recorded using a single channel dc-SQUID, second order gradiometer in an unshielded laboratory. The latency (ms) and amplitude (fT) of the most prominant positive peak within the first 130 ms (P100M) were measured. Blurring the 32' checks significantly increased latency aand reduced the amplitude of the P100M peak. The resulting response curves were parabolic with minimum latency and maximum amplitude recorded at 0 D. Blurring the 70' check had no significant effect on latency or amplitude. Hence, the magnetic P100M responds similarly to the electrical P100 in response to blur. It would be essential when recording the VEMR that vision is corrected with non-magnetic spectacles especially when small checks are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemispheric differences in the learning and generalization of pattern categories were explored in two experiments involving sixteen patients with unilateral posterior, cerebral lesions in the left (LH) or right (RH) hemisphere. In each experiment participants were first trained to criterion in a supervised learning paradigm to categorize a set of patterns that either consisted of simple geometric forms (Experiment 1) or unfamiliar grey-level images (Experiment 2). They were then tested for their ability to generalize acquired categorical knowledge to contrast-reversed versions of the learning patterns. The results showed that RH lesions impeded category learning of unfamiliar grey-level images more severely than LH lesions, whereas this relationship appeared reversed for categories defined by simple geometric forms. With regard to generalization to contrast reversal, categorization performance of LH and RH patients was unaffected in the case of simple geometric forms. However, generalization to of contrast-reversed grey-level images distinctly deteriorated for patients with LH lesions relative to those with RH lesions, with the latter (but not the former) being consistently unable to identify the pattern manipulation. These findings suggest a differential use of contrast information in the representation of pattern categories in the two hemispheres. Such specialization appears in line with previous distinctions between a predominantly lefthemispheric, abstract-analytical and a righthemispheric, specific-holistic representation of object categories, and their prediction of a mandatory representation of contrast polarity in the RH. Some implications for the well-established dissociation of visual disorders for the recognition of faces and letters are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of cholinergic agents undergoing clinical trials for the treatment of Alzheimer's disease and the anticholinergic agent scopolamine, were investigated on the components of the flash and pattern reversal visual evoked potentials (VEPs) in young healthy volunteers. The effect of recording the flash and pattern reversal VEPs for 13 hours in 5 healthy male volunteers, revealed no statistically significant change in the latency or amplitude measures. Administration of the muscarinic agonist SDZ 210-086 to 16 healthy male volunteers resulted in the reduction of the flash N2-P2 and pattern reversal N75-P100 peak-to-peak amplitudes. These effects on the flash VEP occurred at both doses (0.5 and 1.0 mg/day), but only at the higher dose on the pattern reversal VEP. Administration of the antimuscarinic agent scopolamine to 11 healthy young male volunteers, resulted in a delay of the flash P2 latency but no effect on the pattern reversal P100 latency. The pattern reversal N75-P100 peak-to-peak amplitude was also increased post dosing. The combination of scopolamine with the acetylcholinesterase inhibitor SDZ ENA 713 resulted in no significant effect on the flash and pattern reversal VEPs, suggesting that the effects of scopolamine may have been partially reversed. Topical application of scopolamine in 6 young healthy volunteers also resulted in no statistically significant effects on the flash and pattern reversal VEPs. The selective effect of scopolamine on the flash P2 latency but not on the pattern reversal P100 latency, provided a model whereby new cholinergic agents developed for the treatment of Alzheimer's disease can be investigated on a physiological basis. In addition, the results of this study led to the hypothesis that the selective flash P2 delay in Alzheimer's disease was probably due to a cholinergic deficit in both the tectal pathway from the retina to the visual cortex and the magnocellular path of the geniculostriate pathway, whereas the lack of an effect on the pattern reversal P100 component was probably due to a sparing of the parvocellular geniculostriate pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problems of using a single channel magnetometer (BTi, Model 601) in an unshielded clinical environment to measure visual evoked magnetic responses (VEMR) were studied. VEMR to flash and pattern reversal stimuli were measured in 100 normal subjects. Two components, the P100M to pattern reversal and P2M to flash, were measured successfully in the majority of patients. The mean latencies of these components in different decades of life were more variable than the visual evoked potentials (VEP) that have been recorded to these stimuli. The latency of the P100M appeared to increase significantly after about 55 years of age whereas little change occurred for the flash P2M. The effects of blur, check size, stimulus size and luminance intensity on the latency and amplitude of the VEMR were studied. Blurring a small (32') check significantly increased latency whereas blurring a large (70') check had little effect on latency. Increasing check size significantly reduced latency of the P100M but had little effect on amplitude. Increasing the field size decreases the latency and increases the amplitude of the P100M. Within a normal subject, most of the temporal variability of the P100M appeared to be associated with run to run variation rather than between recording sessions on the same day or between days. Reproducibility of the P100M was improved to a degree by employing a magnetically shielded room. Increasing flash intensity decreases the latency and increases the amplitude of the P2M component. The magnitude of the effects of varying stimulus parameters on the VEMR were frequently greater than is normally seen in the VEP. The topography of the P100M and P2M varied over the scalp in normal subjects. Full field responses to a large check could be explained as approximately the sum of the half field responses and were consistent with the cruciform model of the visual cortex. Preliminary source localisation data suggested a shallower source in the visual cortex for the flash P2M compared with the P100M. The data suggest that suitable protocols could be devised to obtain normative data of sufficient quality to use the VEMR to flash and pattern clinically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electroretinogram evoked by reversal pattern stimulation (rPERG) is known to contain both pattern contrast and luminance related components. The retinal mechanisms of the transient rPERGs subserving these functional characteristics are the main concern in the present studies. Considerable attention has been paid to the luminance-related characteristics of the response. The transient PERGs were found to consist of two subsequent processes using low frequency attenuation analysis. The processes overlapped and the individual difference in each process timings formed the major cause for the variations of the negative potential waveform of the transient rPERGs. Attention has been paid to those having ‘notch’ type of variation. Under different contrast levels, the amplitudes of the positive and negative potentials were linearly increased with higher contrast level and the negative potential showed a higher sensitivity to contrast changes and higher contrast gain. Under lower contrast levels, the decreased amplitudes made the difference in the timing course of the positive and negative processes evident, interpreting the appearance of the notch in some cases. Visual adaptation conditions for recording the transient rPERG were discussed. Another effort was to study the large variation of the transient rPERGs (especially the positive potential, P50) in the elderly who’s distant and near visual acuity were normal. It was found that reduction of retinal illumination contributed mostly to the P50 amplitude loss and contrast loss mostly to the negative potential (N95) amplitude loss. Senile miosis was thought to have little effect on the reduction of the retinal illumination, while the changes in the optics of the eye was probably the major cause for it, which interpreted the larger individual variation of the P50 amplitude of the elderly PERGs. Convex defocus affected the transient rPERGs more effectively than concave lenses, especially the N95 amplitude in the elderly. The disability of accommodation and the type and the degree of subjects’ ametropia should be taken into consideration when the elderly rPERGs were analysed.