8 resultados para RADIATION DOSE UNITS
em Aston University Research Archive
Resumo:
We have studied Co60 gamma-irradiation effect on the characteristics of Type IA fiber Bragg gratings. A record Bragg peak shift of 190 pm was observed for a grating written in Fibercore PS-1250/1500 photosensitive fiber at a radiation dose of 116 kGy. Type IA and Type I gratings show different kinetics under radiation and during post-radiation annealing, which can be used for the design of a grating based dosimetry system.
Resumo:
We have studied Co60 ionizing radiation effect on the characteristics of Type IA fiber Bragg gratings. A record Bragg peak shift of 190 pm was observed for a grating written in Fibercore PS-1250/1500 photosensitive fiber at a radiation dose of 116 kGy. Type IA and Type I gratings show different kinetics under radiation and during post-radiation annealing, which can be used for the design of a grating based dosimetry system.
Resumo:
We have studied Co60 gamma-irradiation effect on the characteristics of Type IA fiber Bragg gratings. A record Bragg peak shift of 190 pm was observed for a grating written in Fibercore PS-1250/1500 photosensitive fiber at a radiation dose of 116 kGy. Type IA and Type I gratings show different kinetics under radiation and during post-radiation annealing, which can be used for the design of a grating based dosimetry system.
Resumo:
We have studied Co60 ionizing radiation effect on the characteristics of Type IA fiber Bragg gratings. A record Bragg peak shift of 190 pm was observed for a grating written in Fibercore PS-1250/1500 photosensitive fiber at a radiation dose of 116 kGy. Type IA and Type I gratings show different kinetics under radiation and during post-radiation annealing, which can be used for the design of a grating based dosimetry system.
Resumo:
Type IA fiber gratings have unusual physical properties compared with other grating types. We compare with performance characteristics of Type IA and Type I Bragg gratings exposed to the effects of Co60 gamma-irradiation. A Bragg peak shift of 190 pm was observed for Type IA gratings written in Fibercore PS-1250/1500 photosensitive fiber at a radiation dose of 116 kGy. This is the largest wavelength shift recorded to date under radiation exposure. The Type IA and Type I gratings show different kinetics under radiation and during post-radiation annealing; this can be exploited for the design of a grating based dosimetry system. © 2012 SPIE.
Resumo:
To assess the quantity and nature of prescribed medicines with potential for misuse returned to community pharmacies and general practice surgeries. Setting Community pharmacies (n = 51, 85% total) and general practice surgeries (n = 42, 69%) within the boundaries of Eastern Birmingham Primary Care Trust, UK. Method Medicines returned spontaneously by patients to participating sites were collected over eight weeks in May and June 2003. Data were recorded for each medicinal item including: patient sex, recommended International Non-proprietary Name (rINN), strength, form, legal classification, quantity and number of doses per day. Medicines were categorised into BWF therapeutic groups. A 'medicinal item' was defined as the total number of dose units of a medicine of the same form, strength and date of issue, returned for a given patient. Key findings Medicines were returned from 910 patients comprising 3765 medicinal items (2782 (73.9%) prescription-only medicines and 356 (9.5%) controlled drugs). Substantial amounts of unused, prescribed medicines with potential to cause harm or for misuse were returned, with analgesics, psychoactive and antiepileptic agents comprising 19.4% of returned medicinal items. Medicines of note that were returned included paracetamol-containing medicines (16 630 tablets), morphine (56 g), diamorphine (4.3 g), tramadol (2840 tablets and capsules), benzodiazepines (677 tablets) and tricyclic antidepressants (2831 tablets). Conclusions Substantial quantities of prescribed medicines with potential to cause harm or be misused are routinely present in the community. The management of these unused medicines, and in particular controlled drugs, Is currently inadequate and further work is required to identify the legislative and patient-centred processes required to minimise the potential for these medicines to be misused or cause harm. © 2007 The Authors.
Resumo:
Focal points: Self-completion questionnaires were used to determine issues with compliance surrounding the use of oral chemotherapy in haematology patients Forty-two patients were identified of which 40 responded over a two-month period Twenty-one respondents (52.5 per cent) indicated that they experienced difficulties in taking their medication Difficulties were not apparently related to the time of dosing; the size of dose units (hydroxyurea) and foil packed agents caused particular difficulties
Resumo:
Measurements of neutron and gamma dose rates in mixed radiation fields, and gamma dose rates from calibrated gamma sources, were performed using a liquid scintillation counter NE213 with a pulse shape discrimination technique based on the charge comparison method. A computer program was used to analyse the experimental data. The radiation field was obtained from a 241Am-9Be source. There was general agreement between measured and calculated neutron and gamma dose rates in the mixed radiation field, but some disagreement in the measurements of gamma dose rates for gamma sources, due to the dark current of the photomultiplier and the effect of the perturbation of the radiation field by the detector. An optical fibre bundle was used to couple an NE213 scintillator to a photomultiplier, in an attempt to minimise these effects. This produced an improvement in the results for gamma sources. However, the optically coupled detector system could not be used for neutron and gamma dose rate measurements in mixed radiation fields. The pulse shape discrimination system became ineffective as a consequence of the slower time response of the detector system.