10 resultados para Prospective Randomized Trial

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the efficacy and safety of ranibizumab and bevacizumab intravitreal injections to treat neovascular age-related macular degeneration (nAMD). DESIGN: Multicenter, noninferiority factorial trial with equal allocation to groups. The noninferiority limit was 3.5 letters. This trial is registered (ISRCTN92166560). PARTICIPANTS: People >50 years of age with untreated nAMD in the study eye who read =25 letters on the Early Treatment Diabetic Retinopathy Study chart. METHODS: We randomized participants to 4 groups: ranibizumab or bevacizumab, given either every month (continuous) or as needed (discontinuous), with monthly review. MAIN OUTCOME MEASURES: The primary outcome is at 2 years; this paper reports a prespecified interim analysis at 1 year. The primary efficacy and safety outcome measures are distance visual acuity and arteriothrombotic events or heart failure. Other outcome measures are health-related quality of life, contrast sensitivity, near visual acuity, reading index, lesion morphology, serum vascular endothelial growth factor (VEGF) levels, and costs. RESULTS: Between March 27, 2008 and October 15, 2010, we randomized and treated 610 participants. One year after randomization, the comparison between bevacizumab and ranibizumab was inconclusive (bevacizumab minus ranibizumab -1.99 letters, 95% confidence interval [CI], -4.04 to 0.06). Discontinuous treatment was equivalent to continuous treatment (discontinuous minus continuous -0.35 letters; 95% CI, -2.40 to 1.70). Foveal total thickness did not differ by drug, but was 9% less with continuous treatment (geometric mean ratio [GMR], 0.91; 95% CI, 0.86 to 0.97; P = 0.005). Fewer participants receiving bevacizumab had an arteriothrombotic event or heart failure (odds ratio [OR], 0.23; 95% CI, 0.05 to 1.07; P = 0.03). There was no difference between drugs in the proportion experiencing a serious systemic adverse event (OR, 1.35; 95% CI, 0.80 to 2.27; P = 0.25). Serum VEGF was lower with bevacizumab (GMR, 0.47; 95% CI, 0.41 to 0.54; P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To assess the surface tear breakup time and clinical performance of three daily disposable silicone hydrogel contact lenses over 16 hours of wear. METHODS: Thirty-nine patients (mean [±SD] age, 22.1 [±3.5] years) bilaterally wore (narafilcon A, filcon II-3, and delefilcon A) contact lenses in a prospective, randomized, masked, 1-week crossover clinical trial. Tear film was assessed by the tear meniscus height (TMH), ocular/contact lens surface temperature dynamics, and lens surface noninvasive breakup time at 8, 12, and 16 hours of wear. Clinical performance and ocular physiology were assessed by subjective questionnaire, by high-/low-contrast logMAR (logarithm of the minimum angle of resolution) acuity, and through bulbar and limbal hyperemia grading. Corneal and conjunctival staining were assessed after lens removal. RESULTS: Delefilcon A demonstrated a longer noninvasive breakup time (13.4 [±4.4] seconds) than filcon II-3 (11.6 [±3.7] seconds; p < 0.001) and narafilcon A (12.3 [±3.7] seconds; p < 0.001). A greater TMH (0.35 [±0.11] mm) was shown by delefilcon A than filcon II-3 (0.32 [±0.10] seconds; p = 0.016). Delefilcon A showed less corneal staining after 16 hours of lens wear (0.7 [±0.6] Efron grade) than filcon II-3 (1.1 [±0.7]; p < 0.001) and narafilcon A (0.9 [±0.7]; p = 0.031). Time was not a significant factor for prelens tear film stability (F = 0.594, p = 0.555) or TMH (F = 0.632, p = 0.534). Lens brand did not affect temperature (F = 1.220, p = 0.308), but it decreased toward the end of the day (F = 19.497, p < 0.001). Comfort, quality of vision, visual acuity and contrast acuity, and limbal grading were similar between the lens brands but decreased with time during the day (p < 0.05). CONCLUSIONS: The tear breakup time over the contact lens surface differed between lens types and may have a role in protecting the ocular surface.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To convert objective image analysis of anterior ocular surfaces into recognisable clinical grades, in order to provide a more sensitive and reliable equivalent to current subjective grading methods; a prospective, randomized study correlating clinical grading with digital image assessment. Methods. The possible range of clinical presentations Of bulbar and palpebral hyperaemia, palpebral roughness and corneal staining were represented by 4 sets of 10 images. The images were displayed in random order and graded by 50 clinicians using both subjective CCLRU and Efron grading scales. Previously validated objective image analysis was performed 3 times oil each of the 40 images. Digital measures included edge-detection and relative-coloration components. Step-wise regression analysis determined correlations between the average subjective grade and the objective image analysis measures. Results. Average subjective grades Could be predicted by a combination of the objective image analysis components. These digital ``grades'' accounted for between 69%, (for Efron scale-graded palpebral redness) and 98% (for Efron scale-graded bulbar hyperaemia) of the subjective variance. Conclusions. The results indicate that clinicians may use a combination of vessel areas and overall hue in their judgment of clinical severity for certain conditions. Objective grading call take these aspects into account, and be used to predict an average ``objective grade'' to be used by a clinician in describing the anterior eye. These measures are more sensitive and reliable than subjective grading while still utilizing familiar terminology, and can be applied in research or practice to improve the detection, and monitoring of ocular surface changes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Brain stem death can elicit a potentially manipulable cardiotoxic proinflammatory cytokine response. We investigated the prevalence of this response, the impact of donor management with tri-iodothyronine (T3) and methylprednisolone (MP) administration, and the relationship of biomarkers to organ function and transplant suitability. METHODS: In a prospective randomized double-blinded factorially designed study of T3 and MP therapy, we measured serum levels of interleukin-1 and -6 (IL-1 and IL-6), tumor necrosis factor-alpha (TNF-alpha), C-reactive protein, and procalcitonin (PCT) levels in 79 potential heart or lung donors. Measurements were performed before and after 4 hr of algorithm-based donor management to optimize cardiorespiratory function and +/-hormone treatment. Donors were assigned to receive T3, MP, both drugs, or placebo. RESULTS: Initial IL-1 was elevated in 16% donors, IL-6 in 100%, TNF-alpha in 28%, CRP in 98%, and PCT in 87%. Overall biomarker concentrations did not change between initial and later measurements and neither T3 nor MP effected any change. Both PCT (P =0.02) and TNF-alpha (P =0.044) levels were higher in donor hearts with marginal hemodynamics at initial assessment. Higher PCT levels were related to worse cardiac index and right and left ventricular ejection fractions and a PCT level more than 2 ng x mL(-1) may attenuate any improvement in cardiac index gained by donor management. No differences were observed between initially marginal and nonmarginal donor lungs. A PCT level less than or equal to 2 ng x mL(-1) but not other biomarkers predicted transplant suitability following management. CONCLUSIONS: There is high prevalence of a proinflammatory environment in the organ donor that is not affected by tri-iodothyronine or MP therapy. High PCT and TNF-alpha levels are associated with donor heart dysfunction. (C) 2009 Lippincott Williams & Wilkins, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background - Menorrhagia is a common problem, yet evidence to inform decisions about therapy is limited. In a pragmatic, multicenter, randomized trial, we compared the levonorgestrel-releasing intrauterine system (levonorgestrel-IUS) with usual medical treatment in women with menorrhagia who presented to their primary care providers. Methods - We randomly assigned 571 women with menorrhagia to treatment with levonorgestrel-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined estrogen–progestogen, or progesterone alone). The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) (ranging from 0 to 100, with lower scores indicating greater severity), assessed over a 2-year period. Secondary outcomes included general quality-of-life and sexual-activity scores and surgical intervention. Results - MMAS scores improved from baseline to 6 months in both the levonorgestrel-IUS group and the usual-treatment group (mean increase, 32.7 and 21.4 points, respectively; P<0.001 for both comparisons). The improvements were maintained over a 2-year period but were significantly greater in the levonorgestrel-IUS group than in the usual-treatment group (mean between-group difference, 13.4 points; 95% confidence interval, 9.9 to 16.9; P<0.001). Improvements in all MMAS domains (practical difficulties, social life, family life, work and daily routine, psychological well-being, and physical health) were significantly greater in the levonorgestrel-IUS group than in the usual-treatment group, and this was also true for seven of the eight quality-of-life domains. At 2 years, more of the women were still using the levonorgestrel-IUS than were undergoing the usual medical treatment (64% vs. 38%, P<0.001). There were no significant between-group differences in the rates of surgical intervention or sexual-activity scores. There were no significant differences in serious adverse events between groups. Conclusions - In women with menorrhagia who presented to primary care providers, the levonorgestrel-IUS was more effective than usual medical treatment in reducing the effect of heavy menstrual bleeding on quality of life. (Funded by the National Institute of Health Research Health Technology Assessment Programme; ECLIPSE Controlled-Trials.com number, ISRCTN86566246.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACT: Menorrhagia is a common problem that interferes with a woman’s physical, emotional, and social life. Evidence to guide physicians for decision about therapy for heavy menstrual bleeding is lacking. One treatment option, the levonorgestrel-releasing intrauterine system (levonorgestrel-IUS), has been available in the United States since 2009. Updated meta-analyses comparing the levonorgestrel-IUS with nonhormonal and hormonal treatments showed that the levonorgestrel-IUS produced a greater reduction in menstrual blood loss at 3 to 12 months of follow-up. It is not clear whether these short-term benefits persist. Moreover, the rates of discontinuation of the levonorgestrel-IUS at 2 years are as high as 28%, and effects on bleeding-related quality of life are not known. This pragmatic, multicenter, randomized trial compared the effectiveness of the levonorgestrel-IUS with that of usual medical treatment among women with menorrhagia in a primary care setting. A total of 571 women with menorrhagia were randomized to treatment with levonorgestrel-IUS (n = 285) or usual medical treatment (n = 286). Usual treatment was tranexamic acid, mefenamic acid, combined estrogen-progestogen, or progesterone alone. The primary study outcome measure was the patient-reported score on the condition-specific Menorrhagia Multi-Attribute Scale (MMAS) assessed over a 2-year period. The MMAS scores range from 0 to 100, with lower scores indicating greater severity. Summary MMAS scores were assessed at 6, 12, and 24 months. Secondary outcome measures included general health-related quality of life, sexual-activity scores, and surgical intervention. There was a significant improvement in total MMAS scores from baseline to 6 months in both the levonorgestrel-IUS group and the usual-treatment group; the mean increase was 32.7 and 21.4 points, respectively; P < 0.001 for both comparisons. Over the 2-year follow-up, improvements were maintained in both groups but were significantly greater in the levonorgestrel-IUS group (mean between-group difference, 13.4 points; 95% confidence interval, 9.9–16.9; P < 0.001). Significantly greater improvements in all MMAS domains (practical difficulties, social life, psychological health, physical health, work and daily routine, and family life and relationships) occurred with the levonorgestrel-IUS than with the usual treatment (P < 0.001 with the use of a test for trend). This was also found for 7 of the 8 quality-of-life domains. At the 2-year end point, almost twice as many women were still using the levonorgestrel-IUS than were those receiving the usual medical treatment (64% vs 38%, P < 0.001). No significant between-group differences were noted in the rates of surgical intervention or sexual-activity scores as well as in the frequency of serious adverse events. These data show that levonorgestrel-IUS is more effective than usual medical treatment in improving the quality of life of women with menorrhagia in a primary care setting.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To determine the effect of coloured light filter overlays on reading rates for people with age-related macular degeneration (AMD). Method: Using a prospective clinical trial design, we examined the null hypothesis that coloured light filter overlays do not improve reading rates in AMD when compared to a clear filter. Reading rates for 12 subjects with non-exudative AMD, associated with a relative scotoma and central fixation (mean age 81 years, SD 5.07 years) were determined using the Rate of Reading Test® (printed, nonsense, lower case sans serif, stationary text) with 10 different, coloured light filter overlays (Intuitive Overlays®; figures in brackets are percentage transmission values); rose (78%), pink (78%), purple (67%), aqua (81%), blue (74%), lime-green (86%), mint-green (85%), yellow (93%), orange (83%) and grey (71%). A clear overlay (Roscolene # 00) (360 cdm-2) with 100% transmittance was used as a control. Results: ANOVA indicated that there was no statistically significant difference in reading rates with the coloured light filter overlays compared to the clear filter. Furthermore, chi-squared analysis indicated that the rose, purple and blue filters had a significantly poorer overall ranking in terms of reading rates compared to the other coloured and clear light filters. Conclusion: Coloured light filter overlays are unlikely to provide a clinically significant improvement in reading rates for people with non-exudative AMD associated with a relative scotoma and central fixation. Copyright © Acta Ophthalmol Scand 2004.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objective: The aim of the study is to determine the effect of lutein combined with vitamin and mineral supplementation on contrast sensitivity in people with age-related macular disease (ARMD). Design: A prospective, 9-month, double-masked randomized controlled trial. Setting: Aston University, Birmingham, UK and a UK optometric clinical practice. Subjects: Age-related maculopathy (ARM) and atrophic age-related macular degeneration (AMD) participants were randomized (using a random number generator) to either placebo (n = 10) or active (n=15) groups. Three of the placebo group and two of the active group dropped out. Interventions: The active group supplemented daily with 6 mg lutein combined with vitamins and minerals. The outcome measure was contrast sensitivity (CS) measured using the Pelli-Robson chart, for which the study had 80% power at the 5% significance level to detect a change of 0.3log units. Results: The CS score increased by 0.07 ± 0.07 and decreased by 0.02 ± 0.18 log units for the placebo and active groups, respectively. The difference between these values is not statistically significant (z = 0.903, P = 0.376). Conclusion: The results suggest that 6 mg of lutein supplementation in combination with other antioxidants is not beneficial for this group. Further work is required to establish optimum dosage levels.