45 resultados para Pre-clinical tests
em Aston University Research Archive
Resumo:
The combination of dimethyl dioctadecyl ammonium bromide (DDA) and the synthetic cord factor trehalose dibehenate (TDB) with Ag85B-ESAT-6 (H1 fusion protein) has been found to promote strong protective immune responses against Mycobacterium tuberculosis. The development of a vaccine formulation that is able to facilitate the requirements of sterility, stability and generation of a vaccine product with acceptable composition, shelf-life and safety profile may necessitate selected alterations in vaccine formulation. This study describes the implementation of a sterilisation protocol and the use of selected lyoprotective agents in order to fulfil these requirements. Concomitantly, close analysis of any alteration in physico-chemical characteristics and parameters of immunogenicity have been examined for this promising DDA liposome-based tuberculosis vaccine. The study addresses the extensive guidelines on parameters for non-clinical assessment, suitable for liposomal vaccines and other vaccine delivery systems issued by the World Health Organisation (WHO) and the European Medicines Agency (EMEA). Physical and chemical stability was observed following alteration in formulations to include novel cryoprotectants and radiation sterilisation. Immunogenicity was maintained following these alterations and even improved by modification with lysine as the cryoprotective agent for sterilised formulations. Taken together, these results outline the successful alteration to a liposomal vaccine, representing improved formulations by rational modification, whilst maintaining biological activity.
Resumo:
Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.
Resumo:
The devastating impact of Type 2 Diabetes Mellitus (T2DM) -related morbidity and mortality on global healthcare is escalating with higher prevalences of obesity, poor diet, and sedentary lifestyles. Therefore, the clinical need for early diagnosis and prevention in groups of high-risk individuals is necessary. The purpose of this thesis was to investigate the use of surrogate markers, namely retinal vascular function, to determine future vascular endothelial dysfunction, atherosclerosis, large vessel disease and cardiovascular risk in certain groups. This namely covered normoglycaemic and normotensive South Asians (SAs), those with Impaired-Glucose Tolerance (IGT) and individuals with a familial history (FH) of T2DM. Additionally the effect of overweight and obesity was studied. The techniques and modified protocols adopted for this thesis involved the investigation of endothelial function by means of vascular reactivity at the ocular and systemic level. Furthermore, the relationships between retinal and systemic function with circulating markers for endothelial cell function and cardiovascular risk markers were explored. The principal studies and findings of the research were: Vascular Function in Normoglycaemic Individuals with and without a FH of T2DM WE FH individuals exhibited higher levels of total cholesterol levels that correlated well with the retinal arterial dilation amplitude to flicker light stimulus. However this did not extend to noticeable differences in markers for endothelial cell damage and impaired retinal and systemic function. Vascular Function in Normoglycaemic South-Asians vs. White-Europeans without a FH and Vascular Disturbances Compared to healthy WEs (normo -glycaemic and -tensive), SA participants exhibited levels of dyslipidaemia and a state of oxidative stress that extended to impaired vascular function as detected by reduced brachial artery flow-mediated dilation, slower retinal arterial vessel dilation reaction times (Appendix 3) and steeper constriction profiles. Furthermore, gender sub-group analysis presented in a sub-chapter shows that SA males demonstrated 24-hour systemic blood pressure (BP) and heart rate variability (HRV) abnormalities and heightened cardiovascular disease (CVD) risk. Vascular Function in Individuals Newly Diagnosed with IGT as compared to Normoglycaemic Healthy Controls Newly-diagnosed WE and SA IGT patients showed a greater risk for CVD and T2DM progression by means of 24-hour BP abnormalities, dyslipidaemia, increased carotid artery intimal-media thickness (c-IMT), Framingham scores and cholesterol ratios. Additionally, pre-clinical markers for oxidative stress and endothelial dysfunction, as evident by significantly lower levels of plasma glutathione and increased levels of von-Willebrand factor in IGT individuals, extended to impaired vascular systemic and retinal function compared to normal controls. This originally shows retinal, systemic and biochemical disturbances in newly-diagnosed IGT not previously reported before. Vascular Function in Normal, Overweight and Obese Individuals of SA and WE Ethnicity In addition to the intended study chapters, the thesis also investigated the influence of obesity and overweight on vascular function. Most importantly, it was found for the first time that compared to lean individuals it was overweight and not obese individuals that exhibited signs of vascular systemic and ocular dysfunction that was evident alongside markers of atherosclerosis, CVD risk and endothelial damage.
Resumo:
Particulate delivery systems such as liposomes and polymeric nano- and microparticles are attracting great interest for developing new vaccines. Materials and formulation properties essential for this purpose have been extensively studied, but relatively little is known about the influence of the administration route of such delivery systems on the type and strength of immune response elicited. Thus, the present study aimed at elucidating the influence on the immune response when of immunising mice by different routes, such as the subcutaneous, intradermal, intramuscular, and intralymphatic routes with ovalbumin-loaded liposomes, N-trimethyl chitosan (TMC) nanoparticles, and poly(lactide-co-glycolide) (PLGA) microparticles, all with and without specifically selected immune-response modifiers. The results showed that the route of administration caused only minor differences in inducing an antibody response of the IgG1 subclass, and any such differences were abolished upon booster immunisation with the various adjuvanted and non-adjuvanted delivery systems. In contrast, the administration route strongly affected both the kinetics and magnitude of the IgG2a response. A single intralymphatic administration of all evaluated delivery systems induced a robust IgG2a response, whereas subcutaneous administration failed to elicit a substantial IgG2a response even after boosting, except with the adjuvanted nanoparticles. The intradermal and intramuscular routes generated intermediate IgG2a titers. The benefit of the intralymphatic administration route for eliciting a Th1-type response was confirmed in terms of IFN-gamma production of isolated and re-stimulated splenocytes from animals previously immunised with adjuvanted and non-adjuvanted liposomes as well as with adjuvanted microparticles. Altogether the results show that the IgG2a associated with Th1-type immune responses are sensitive to the route of administration, whereas IgG1 response associated with Th2-type immune responses were relatively insensitive to the administration route of the particulate delivery systems. The route of administration should therefore be considered when planning and interpreting pre-clinical research or development on vaccine delivery systems.
Resumo:
The technique of Satellite Laser Ranging is today a mature, important tool with applications in many area of geodynamics, geodesy and satellite dynamics. A global network of some 40 stations regularly obtains range observations with sub-cm precision to more than twelve orbiting spacecraft. At such levels of precision it is important to minimise potential sources of range bias in the observations, and part of the thesis is a study of subtle effects caused by the extended nature of the arrays of retro-reflectors on the satellites. We develop models that give a precise correction of the range measurements to the centres of mass of the geodetic satellites Lageos and Etalon, appropriate to a variety of different ranging systems, and use the Etalon values, which were not determined during pre-launch tests, in an extended orbital analysis. We have fitted continuous 2.5 year orbits to range observations of the Etalons from the global network of stations, and analysed the results by mapping the range residuals from these orbits into equivalent corrections to orbital elements over short time intervals. From these residuals we have detected and studied large un-modelled along-track accelerations associated with periods during which the satellites are undergoing eclipse by the Earth's shadow. We also find that the eccentricity residuals are significantly different for the two satellites, with Etalon-2 undergoing a year-long eccentricity anomaly similar in character to that experienced at intervals by Lageos-1. The nodal residuals show that the satellites define a very stable reference frame for Earth rotation determination, with very little drift-off during the 2.5 year period. We show that an analysis of more than about eight years of tracking data would be required to derive a significant value for 2. The reference frame defined by the station coordinates derived from the analyses shows very good agreement with that of ITRF93.
Resumo:
Intraocular light scatter is high in certain subject groups eg the elderly, due to increased optical media turbidity, which scatters and attenuates light travelling towards the retina. This causes reduced retinal contrast especially in the presence of glare light. Such subjects have depressed Contrast Sensitivity Functions (CSF). Currently available clinical tests do not effectively reflect this visual disability. Intraocular light scatter may be quantified by measuring the CSF with and without glare light and calculating Light Scatter Factors (LSF). To record the CSF on clinically available equipment (Nicolet CS2000), several psychophysical measurement techniques were investigated, and the 60 sec Method of Increasing Contrast was selected as the most appropriate. It was hypothesised that intraocular light scatter due to particles of different dimensions could be identified by glare sources at wide (30°) and narrow (3.5°) angles. CSFs andLSFs were determined for: (i) Subjects in young, intermediate and old age groups. (ii) Subjects during recovery from large amounts of induced corneal oedema. (iii) A clinical sample of contact lens (CL) wearers with a group of matched controls. The CSF was attenuated at all measured spatial frequencies with the intermediate and old group compared to the young group. High LSF values were found only in the old group (over 60 years). It was concluded that CSF attenuation in the intermediate group was due to reduced pupil size, media absorption and/or neural factors. In the old group, the additional factor was high intraocular light scatter levels of lenticular origin. The rate of reduction of the LSF for the 3.5° glare angle was steeper than that for the 30° angle, following induced corneal oedema. This supported the hypothesis, as it was anticipated that epithelial oedema would recover more rapidly than stromal oedema. CSFs and LSFs were markedly abnormal in the CL wearers. The analytical details and the value of these investigative techniques in contact lens research are discussed.
Resumo:
The enteroinsular axis (EIA) constitutes a physiological signalling system whereby intestinal endocrine cells secrete incretin hormones following feeding that potentiate insulin secretion and contribute to the regulation of blood glucose homeostasis. The two key hormones responsible are named glucagon-like peptide-1 (GLP-1) and glucose-dependent insulinotropic polypeptide (GIP). Recent years have witnessed sustained development of antidiabetic therapies that exploit the EIA. Current clinical compounds divide neatly into two classes. One concerns analogues or mimetics of GLP-1, such as exenatide (Byetta) or liraglutide (NN2211). The other group comprises the gliptins (e.g. sitagliptin and vildagliptin) which boost endogenous incretin activity by inhibiting the enzyme dipeptidyl peptidase 4 (DPP 4) that degrades both GLP-1 and GIP. Ongoing research indicates that further incretin and gliptin compounds will become available for clinical use in the near future, offering comparable or improved efficacy. For incretin analogues there is the prospect of prolonged duration of action and alternative routes of administration. This review focuses on recent advances in pre-clinical research and their translation into clinical studies to provide future therapies for type 2 diabetes targeting the EIA. © 2009 Bentham Science Publishers Ltd.
Resumo:
BACKGROUND: Contrast detection is an important aspect of the assessment of visual function; however, clinical tests evaluate limited spatial frequencies and contrasts. This study validates the accuracy and inter-test repeatability of a swept-frequency near and distance mobile app Aston contrast sensitivity test, which overcomes this limitation compared to traditional charts. METHOD: Twenty subjects wearing their full refractive correction underwent contrast sensitivity testing on the new near application (near app), distance app, CSV-1000 and Pelli-Robson charts with full correction and with vision degraded by 0.8 and 0.2 Bangerter degradation foils. In addition repeated measures using the 0.8 occluding foil were taken. RESULTS: The mobile apps (near more than distance, p = 0.005) recorded a higher contrast sensitivity than printed tests (p < 0.001); however, all charts showed a reduction in measured contrast sensitivity with degradation (p < 0.001) and a similar decrease with increasing spatial frequency (interaction > 0.05). Although the coefficient of repeatability was lowest for the Pelli-Robson charts (0.14 log units), the mobile app charts measured more spatial frequencies, took less time and were more repeatable (near: 0.26 to 0.37 log units; distance: 0.34 to 0.39 log units) than the CSV-1000 (0.30 to 0.93 log units). The duration to complete the CSV-1000 was 124 ± 37 seconds, Pelli-Robson 78 ± 27 seconds, near app 53 ± 15 seconds and distance app 107 ± 36 seconds. CONCLUSIONS: While there were differences between charts in contrast levels measured, the new Aston near and distance apps are valid, repeatable and time-efficient method of assessing contrast sensitivity at multiple spatial frequencies.
Resumo:
Presbyopia is a consequence of ageing and is therefore increasing inprevalence due to an increase in the ageing population. Of the many methods available to manage presbyopia, the use of contact lenses is indeed a tried and tested reversible option for those wishing to be spectacle free. Contact lens options to correct presbyopia include multifocal contact lenses and monovision.Several options have been available for many years with available guides to help choose multifocal contact lenses. However there is no comprehensive way to help the practitioner selecting the best option for an individual. An examination of the simplest way of predicting the most suitable multifocal lens for a patient will only enhance and add to the current evidence available. The purpose of the study was to determine the current use of presbyopic correction modalities in an optometric practice population in the UK and to evaluate and compare the optical performance of four silicone hydrogel soft multifocal contact lenses and to compare multifocal performance with contact lens monovision. The presbyopic practice cohort principal forms of refractive correction were distance spectacles (with near and intermediate vision providedby a variety of other forms of correction), varifocal spectacles and unaided distance with reading spectacles, with few patients wearing contact lenses as their primary correction modality. The results of the multifocal contact lens randomised controlled trial showed that there were only minor differences in corneal physiology between the lens options. Visual acuity differences were observed for distance targets, but only for low contrast letters and under mesopic lighting conditions. At closer distances between 20cm and 67cm, the defocus curves demonstrated that there were significant differences in acuity between lens designs (p < 0.001) and there was an interaction between the lens design and the level of defocus (p < 0.001). None of the lenses showed a clear near addition, perhaps due to their more aspheric rather than zoned design. As expected, stereoacuity was reduced with monovision compared with the multifocal contact lens designs, although there were some differences between the multifocal lens designs (p < 0.05). Reading speed did not differ between lens designs (F = 1.082, p = 0.368), whereas there was a significant difference in critical print size (F = 7.543, p < 0.001). Glare was quantified with a novel halometer and halo size was found to significantly differ between lenses(F = 4.101, p = 0.004). The rating of iPhone image clarity was significantly different between presbyopic corrections (p = 0.002) as was the Near Acuity Visual Questionnaire (NAVQ) rating of near performance (F = 3.730, p = 0.007).The pupil size did not alter with contact lens design (F = 1.614, p = 0.175), but was larger in the dominant eye (F = 5.489, p = 0.025). Pupil decentration relative to the optical axis did not alter with contact lens design (F = 0.777, p =0.542), but was also greater in the dominant eye (F = 9.917, p = 0.003). It was interesting to note that there was no difference in spherical aberrations induced between the contact lens designs (p > 0.05), with eye dominance (p > 0.05) oroptical component (ocular, corneal or internal: p > 0.05). In terms of subjective patient lens preference, 10 patients preferred monovision,12 Biofinity multifocal lens, 7 Purevision 2 for Presbyopia, 4 AirOptix multifocal and 2 Oasys multifocal contact lenses. However, there were no differences in demographic factors relating to lifestyle or personality, or physiological characteristics such as pupil size or ocular aberrations as measured at baseline,which would allow a practitioner to identify which lens modality the patient would prefer. In terms of the performance of patients with their preferred lens, it emerged that Biofinity multifocal lens preferring patients had a better high contrast acuity under photopic conditions, maintained their reading speed at smaller print sizes and subjectively rated iPhone clarity as better with this lens compared with the other lens designs trialled. Patients who preferred monovision had a lower acuity across a range of distances and a larger area of glare than those patients preferring other lens designs that was unexplained by the clinical metrics measured. However, it seemed that a complex interaction of aberrations may drive lens preference. New clinical tests or more diverse lens designs which may allow practitioners to prescribe patients the presbyopic contact lens option that will work best for them first time remains a hope for the future.
Resumo:
Full Text: August 2001 saw the birth of the British Journal of Diabetes & Vascular Disease (Figure 1): an open-access peer review journal.1 Free to publish and free to read. The founding editorial board and publisher (MediNews Diabetes) aimed to deliver a free journal to the diabetes team and vascular professionals with a special interest in diabetes. Despite the shifting sands of time and a change of publisher (SAGE) the journal has remained true to its founding philosophy - publication is on merit, not on ability to pay and free online access remains available worldwide (www.bjdvd.com) plus an extensive – mainly UK - print circulation. Evolution- The journal attracted much attention and was soon receiving good quality experimental and clinical science manuscripts. However it was felt that these articles, especially experimental and pre-clinical studies, were not within the focus of the British Journal of Diabetes & Vascular Disease, thus Diabetes & Vascular Disease Research was conceived –and is now also a SAGE journal and has an impact factor of 2.59. Over the years the organisation of topics has changed, for example the Healthcare management, The diabetes care team and Trans-cultural medicine sections have been absorbed into the Achieving Best Practice and Current Topics sections which better reflect the broader-based content of submitted material. Landmark Studies was a regular highly popular section – but how many truly Landmark Studies are undertaken? Not enough to warrant special attention 6 times a year for 12 years. Interestingly one of the studies reviewed is consistently amongst the top ten of our most read online articles.2 The British Journal of Diabetes & Vascular Disease has also challenged convention with the production of two Jubilee issues.3,4 The celebrations for the golden and diamond jubilees of Her Majesty Queen Elizabeth II afforded opportunities to reflect on changes in the understanding and treatment of diabetes during her reign. Most of the articles in these issues were written by authors who had first hand experience of the changing face of diabetes and vascular disease care. The increased costs of print and post – both financially and environmentally mean that digital communications are likely to become more popular (assuming that these approaches have a smaller ecological footprint). The British Journal of Diabetes & Vascular Disease is pleased to be able to celebrate its 12th birthday as an original open-access journal, with an ongoing commitment to support authors to publish free of charge whilst providing free reader access. As for what the future holds: tomorrow is another day. References 1.British Journal of Diabetes & Vascular Disease 2001; 1: 1-92. 2.Levy J. Impotence and its medical and psychosocial correlates: results of the Massachusetts Male Aging Study. Br J Diabetes Vasc Dis 2002; 2: 278-80. 3.British Journal of Diabetes & Vascular Disease. (Golden Jubilee Issue) 2002; 2: 415-480. 4.British Journal of Diabetes & Vascular Disease. (Diamond Jubilee Issue) 2012; 12: 266-380.
Resumo:
The current platform of conventional cardiovascular risk assessments tends to forsake the importance of endothelial function - a key biological mechanism by which cardiovascular risk factors exert their propensity for adverse vascular events. Moreover, the presence and severity of endothelial dysfunction in ‘low-risk’ individuals suggests considerable variability in pre-clinical risk that could potentially be detected well before the onset of disease. The aim of the present thesis was to investigate the presence and impact of retinal vascular dysfunction, as a barometer of endothelial function, in otherwise healthy individuals with one or more cardiovascular risk factors, but low to moderate cardiovascular risk. Systemic circulatory influences on retinal vascular function were also evaluated. The principle sections and findings of this work are: 1. Ageing effect on retinal vascular function • In low-risk individuals, there are age differences in retinal vascular function throughout the entire functional response curve for arteries and veins. Gender differences mainly affect the dilatory phase and are only present in young individuals. 2. Retinal vascular function in healthy individuals with a family history of cardiovascular disease • In low-risk individuals with a family history of cardiovascular disease, impairments in microvascular function at the retinal level correlate with established plasma markers for cardiovascular risk. 3. Ethnic differences in retinal vascular function • When compared to age-matched White Europeans, in low-risk middle-aged South Asians, there are impairments in retinal vascular function that correlate with established cardiovascular risk indicators. 4. Systemic circulatory influences on retinalµvascular function • Systemic antioxidant capacity (redox index) and plasma markers for cardiovascular risk (lipids) influence retinal microvascular function at both arterial and venous levels. 5. Retinal vascular function in individuals with obstructive sleep apnoea: a preliminarystudy • Patients with moderate to severe sleep apnoea exhibit attenuated retinal vascular function.
Resumo:
OBJECTIVES: Most studies reporting evidence of adverse effects of lead and cadmium on the ability to balance have been conducted in high-exposure groups or have included adults. The effects of prenatal exposure have not been well studied, nor have the effects in children been directly studied. The aim of the study was to identify the associations of lead (in utero and in childhood) and cadmium (in utero) exposure with the ability to balance in children aged 7 and 10 years. DESIGN: Prospective birth cohort study. PARTICIPANTS: Maternal blood lead (n=4285) and cadmium (n=4286) levels were measured by inductively coupled plasma mass spectrometry in women enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC) during pregnancy. Child lead levels were measured in a subsample of 582 of ALSPAC children at age 30 months. MAIN OUTCOME MEASURES: Children completed a heel-to-toe walking test at 7 years. At 10 years, the children underwent clinical tests of static and dynamic balance. Statistical analysis using SPSS V.19 included logistic regression modelling, comparing categories of ≥ 5 vs <5 µg/dL for lead, and ≥ 1 vs <1 µg/L for cadmium. RESULTS: Balance at age 7 years was not associated with elevated in utero lead or cadmium exposure (adjusted OR for balance dysfunction: Pb 1.01 (95% CI 0.95 to 1.01), n=1732; Cd 0.95 (0.77 to 1.20), n=1734), or with elevated child blood lead level at age 30 months (adjusted OR 0.98 (0.92 to 1.05), n=354). Similarly, neither measures of static nor dynamic balance at age 10 years were associated with in utero lead or cadmium exposure, or child lead level. CONCLUSIONS: These findings do not provide any evidence of an association of prenatal exposure to lead or cadmium, or lead levels in childhood, on balance ability in children. Confirmation in other cohorts is needed.
Resumo:
OBJECTIVE: The literature contains many reports of balance function in children, but these are often on atypical samples taken from hospital-based clinics and may not be generalisable to the population as a whole. The purpose of the present study is to describe balance test results from a large UK-based birth cohort study. METHODS: Data from the Avon Longitudinal Study of Parents and Children (ALSPAC) were analysed. A total of 5402 children completed the heel-to-toe walking test at age 7 years. At age 10 years, 6915 children underwent clinical tests of balance including beam-walking, standing heel-to-toe on a beam and standing on one leg. A proportion of the children returned to the clinic for retesting within 3 months allowing test-retest agreement to be measured. RESULTS: Frequency distributions for each of the balance tests are given. Correlations between measures of dynamic balance at ages 7 and 10 years were weak. The static balance of 10 year old children was found to be poorer with eyes closed than with eyes open, and poorer in boys than in girls for all measures. Balance on one leg was poorer than heel-to-toe balance on a beam. A significant learning effect was found when first and second attempts of the tests were compared. Measures of static and dynamic balance appeared independent. Consistent with previous reports in the literature, test-retest reliability was found to be low. CONCLUSIONS: This study provides information about the balance ability of children aged 7 and 10 years and provides clinicians with reference data for balance tests commonly used in the paediatric clinic.