8 resultados para Positive end expiratory pressure

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular diseases (CVD) contributed to almost 30% of worldwide mortality; with heart failure being one class of CVD. One popular and widely available treatment for heart failure is the intra-aortic balloon pump (IABP). This heart assist device is used in counterpulsation to improve myocardial function by increasing coronary perfusion, and decreasing aortic end-diastolic pressure (i.e. the resistance to blood ejection from the heart). However, this device can only be used acutely, and patients are bedridden. The subject of this research is a novel heart assist treatment called the Chronic Intermittent Mechanical Support (CIMS) which was conceived to offer advantages of the IABP device chronically, whilst overcoming its disadvantages. The CIMS device comprises an implantable balloon pump, a percutaneous drive line, and a wearable driver console. The research here aims to determine the haemodynamic effect of balloon pump activation under in vitro conditions. A human mock circulatory loop (MCL) with systemic and coronary perfusion was constructed, capable of simulating various degrees of heart failure. Two prototypes of the CIMS balloon pump were made with varying stiffness. Several experimental factors (balloon inflation/deflation timing, Helium gas volume, arterial compliance, balloon pump stiffness and heart valve type) form the factorial design experiments. A simple modification to the MCL allowed flow visualisation experiments using video recording. Suitable statistical tests were used to analyse the data obtained from all experiments. Balloon inflation and deflation in the ascending aorta of the MCL yielded favourable results. The sudden balloon deflation caused the heart valve to open earlier, thus causing longer valve opening duration in a cardiac cycle. It was also found that pressure augmentation in diastole was significantly correlated with increased cardiac output and coronary flowrate. With an optimum combination (low arterial compliance and low balloon pump stiffness), systemic and coronary perfusions were increased by 18% and 21% respectively, while the aortic end-diastolic pressure (forward flow resistance) decreased by 17%. Consequently, the ratio of oxygen supply and demand to myocardium (endocardial viability ratio, EVR) increased between 33% and 75%. The increase was mostly attributed to diastolic augmentation rather than systolic unloading.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Gram-positive microorganisms, specifically coagulase-negative staphylococci are the most common species recovered from clinical culture specimens of patients with end-stage renal disease. The propensity of coagulase-negative staphylococci (CNS) to cause infection in this patient group has been widely debated. However, it is still unclear how this usually avirulent commensal microorganism produces infection that contributes to high rates of morbidity and mortality in patients with end-stage renal disease. The aim of this thesis was to investigate the rate, geographical distribution, molecular and phenotypic mechanisms of Gram-positive microorganisms associated with infection in renal dialysis patients. In addition, it sought to assess the value of early serological diagnosis of dialysis catheter-associated infection and the effect of antimicrobial treatment regimens on the faecal carriage of enteric microorganisms. In this study, the incidence of haemodialysis catheter-associated infection was established with the Meditrend audit tool. This tool was used to assess the infection outcomes of catheter insertion and management procedures until the catheter was explanted. Introduction of a catheter management protocol decreased the incidence of catheter-related infection. Staphylococcal species recovered from episodes of haemodialysis catheter-associated infection and continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis were genotyped by determination of macrorestriction profiles with pulsed-field gel electrophoresis. This highlighted horizontal transfer of microorganisms between different patients and the environment. The phenotypic characteristics of these strains were also investigated to determine characteristics that could be used as markers for dialysis catheter-associated infection. The expression of elastase, lipase and esterase by CNS was significantly associated with infection. A rapid enzyme-linked immunosorbent assay incorporating a novel staphylococcal antigen (lipid S) was used to evaluate the early detection of anti-staphylococcal immunoglobulin gamma in patient sera. The comparison of culture positive and culture negative patients demonstrated a steady state of immune activation in both groups. However anti-lipid S serum antibody titres > 1000 were found to be a predictor of infection. The effect on faecal carriage of vancomycin resistant enterococci (VRE) and Clostridium difficile toxins in patients treated with CAPD when empiric cephalosporin therapy was substituted for piperacillin/tazobactam was investigated. The introduction of piperacillin/tazobactam demonstrated a decrease in the faecal carriage of VRE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs. Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the relationship between ocular perfusion pressure and color Doppler measurements in patients with glaucoma. MATERIALS AND METHODS: Twenty patients with primary open-angle glaucoma with visual field deterioration in spite of an intraocular pressure lowered below 21 mm Hg, 20 age-matched patients with glaucoma with stable visual fields, and 20 age-matched healthy controls were recruited. After a 20-minute rest in a supine position, intraocular pressure and color Doppler measurements parameters of the ophthalmic artery and the central retinal artery were obtained. Correlations between mean ocular perfusion pressure and color Doppler measurements parameters were determined. RESULTS: Patients with glaucoma showed a higher intraocular pressure (P <.0008) and a lower mean ocular perfusion pressure (P <.0045) compared with healthy subjects. Patients with deteriorating glaucoma showed a lower mean blood pressure (P =.033) and a lower end diastolic velocity in the central retinal artery (P =.0093) compared with normals. Mean ocular perfusion pressure correlated positively with end diastolic velocity in the ophthalmic artery (R = 0.66, P =.002) and central retinal artery (R = 0.74, P <.0001) and negatively with resistivity index in the ophthalmic artery (R = -0.70, P =.001) and central retinal artery (R = -0.62, P =.003) in patients with deteriorating glaucoma. Such correlations did not occur in patients with glaucoma with stable visual fields or in normal subjects. The correlations were statistically significantly different between the study groups (parallelism of regression lines in an analysis of covariance model) for end diastolic velocity (P =.001) and resistivity index (P =.0001) in the ophthalmic artery, as well as for end diastolic velocity (P =.0009) and resistivity index (P =. 001) in the central retinal artery. CONCLUSIONS: The present findings suggest that alterations in ocular blood flow regulation may contribute to the progression in glaucomatous damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sensitivity of a fibre Bragg grating (FBG) sensor fabricated in polymer optical fibre (POF) to hydrostatic pressure was investigated for the first time. In this initial investigative work a reflected Bragg response of a FBG fabricated in multimode microstructured POF (MMmPOF) was monitored, whilst the hydrostatic pressure was increased up to 10MPa. Positive sensitivities were observed, meaning a positive wavelength shift to increasing pressure, as opposed to negative sensitivities monitored when using a FBG sensor fabricated in silica optical fibre. The FBG sensors fabricated in the MMmPOF gave fractional changes in wavelength and hence sensitivities of at least 64.05×10-6/MPa, which is some 25 times larger than the -2.50×10-6/MPa sensitivity of a FBG sensor fabricated in silica optical fibre that was measured in this work. Furthermore this work highlighted a decrease in sensitivity of the FBG sensor fabricated in the MMmPOF by some 50% by sealing the holes of the mPOF at the tip of the fibre with an adhesive. This offers the potential to tailor the response of the sensor to hydrostatic pressure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sensitivity of a fibre Bragg grating (FBG) sensor fabricated in polymer optical fibre (POF) to hydrostatic pressure was investigated for the first time. In this initial investigative work a reflected Bragg response of a FBG fabricated in multimode microstructured POF (MMmPOF) was monitored, whilst the hydrostatic pressure was increased up to 10MPa. Positive sensitivities were observed, meaning a positive wavelength shift to increasing pressure, as opposed to negative sensitivities monitored when using a FBG sensor fabricated in silica optical fibre. The FBG sensors fabricated in the MMmPOF gave fractional changes in wavelength and hence sensitivities of at least 64.05×10-6/MPa, which is some 25 times larger than the -2.50×10-6/MPa sensitivity of a FBG sensor fabricated in silica optical fibre that was measured in this work. Furthermore this work highlighted a decrease in sensitivity of the FBG sensor fabricated in the MMmPOF by some 50% by sealing the holes of the mPOF at the tip of the fibre with an adhesive. This offers the potential to tailor the response of the sensor to hydrostatic pressure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is growing pressure to ensure that future broadband networks are both super fast and ubiquitously available to all users without the need for large government subsidies, this requires a radical change to network architectures. © OSA 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and aims: Diabetic Retinopathy (DR) is a leading cause of blindness. OSA is associated with increased oxidative and nitrosative stress and endothelial dysfunction in patients with type 2 diabetes (T2DM). Hence, it is plausible that OSA can promote the development and progression of DR. Materials and methods: An observational longitudinal study in adults with T2DM. Patients with pre-existing OSA, end-stage renal disease and non-diabetic retinopathy were excluded. OSA (apnoea hypopnea index ≥ 5 events/hour) was assessed by a single overnight home-based cardio-respiratory monitoring (Alice PDX, etc.). DR was assesses using retinal images between 2007 and 2012. Sight threatening retinopathy (STR) was defined as pre-proliferative or proliferative DR, maculopathy or photocoagulation. Advanced DR was defined as pre-proliferative or proliferative DR. Results: 199 patients were included (57.3% men, 47.7% White Europeans). STR and OSA prevalence were 38.7 % and 62.8% respectively. STR preva-lence was higher in patients with OSA (OSA+) compared to those with-out (OSA-) [48.8% vs. 21.6%, p <0.001]. After adjustment for confounders, OSA remained independently associated with STR (OR 3.7, 95%CI 1.6-8.9, p=0.006, maculopathy (OR 4.5, 1.8-11.4, p=0.002) and advanced DR (OR 3.9, 1.02-15.3, p=0.047). Over 4.4±1 years, more OSA+ patients progressed from no or background DR to advanced DR (15.3% vs. 3%, p=0.01). OSA was an independent predictor of advanced DR development after adjustment (OR 6.6, 95%CI 1.2-35.1, p=0.03). OSA did not predict the development of maculopathy. Patients received continuous positive airway pressure treatment were less likely to develop advanced DR. Conclusion: OSA is independently associated with STR and predicts the development of preproliferative and proliferative DR. Interventional studies are needed to assess the impact of OSA treatment on DR.Supported by: NIHR (UK) and The UK Novo Nordisk Research Foundation.