2 resultados para Popular novel
em Aston University Research Archive
Resumo:
To elucidate the structures of orgamc molecules in solution using pulse FT NMR, heteronuclear pulse sequence experiments to probe carbon-13 (13C) and proton (1H) spin systems are invaluable. The one-dimensional insensitive nucleus detected PENDANT experiment finds popular use for structure determination via one-bond 13C-1H scalar couplings. PENDANT facilitates the desired increase in 13C signal-to-noise ratio, and unlike many other pulse sequence experiments (e.g., refocused INEPT and DEPT), allows the simultaneous detection of 13C quaternary nuclei. The tlrst chapter herein details the characterisation of PENDANT and the successful rectification of spectral anomalies that occur when it is used without proton broadband decoupling. Multiple-bond (long-range) l3C-1H scalar coupling correlations can yield important bonding information. When the molecule under scrutiny is devoid of proton spectral crowding, and more sensitive 'inverse' pulse sequence experiments are not available, one may use insensitive nucleus detected long-range selective one-dimensional correlation methods, rather than more time consuming and insensitive multidimensional analogues. To this end a novel long-range selective one-dimensional correlation pulse sequence experiment has been invented. Based on PENDANT, the new experiment is shown to rival the popular selective INEPT technique because it can determine the same correlations while simultaneously detecting isolated 13C quaternary nuclei. INEPT cannot facilitate this, potentially leaving other important quaternary nuclei undetected. The novel sequence has been modified further to yield a second novel experiment that simultaneously yields selective 13C transient nOe data. Consequently, the need to perform the two experiments back-to-back is conveniently removed, and the experimental time reduced. Finally, the SNARE pulse sequence was further developed. SNARE facilitates the reduction of experimental time by accelerating the relaxation of protons upon which pulse sequences, to which SNARE is appended, relies. It is shown, contrary to the original publication, that reiaxation time savings can be derived from negative nOes.
Resumo:
Cardiovascular diseases (CVD) contributed to almost 30% of worldwide mortality; with heart failure being one class of CVD. One popular and widely available treatment for heart failure is the intra-aortic balloon pump (IABP). This heart assist device is used in counterpulsation to improve myocardial function by increasing coronary perfusion, and decreasing aortic end-diastolic pressure (i.e. the resistance to blood ejection from the heart). However, this device can only be used acutely, and patients are bedridden. The subject of this research is a novel heart assist treatment called the Chronic Intermittent Mechanical Support (CIMS) which was conceived to offer advantages of the IABP device chronically, whilst overcoming its disadvantages. The CIMS device comprises an implantable balloon pump, a percutaneous drive line, and a wearable driver console. The research here aims to determine the haemodynamic effect of balloon pump activation under in vitro conditions. A human mock circulatory loop (MCL) with systemic and coronary perfusion was constructed, capable of simulating various degrees of heart failure. Two prototypes of the CIMS balloon pump were made with varying stiffness. Several experimental factors (balloon inflation/deflation timing, Helium gas volume, arterial compliance, balloon pump stiffness and heart valve type) form the factorial design experiments. A simple modification to the MCL allowed flow visualisation experiments using video recording. Suitable statistical tests were used to analyse the data obtained from all experiments. Balloon inflation and deflation in the ascending aorta of the MCL yielded favourable results. The sudden balloon deflation caused the heart valve to open earlier, thus causing longer valve opening duration in a cardiac cycle. It was also found that pressure augmentation in diastole was significantly correlated with increased cardiac output and coronary flowrate. With an optimum combination (low arterial compliance and low balloon pump stiffness), systemic and coronary perfusions were increased by 18% and 21% respectively, while the aortic end-diastolic pressure (forward flow resistance) decreased by 17%. Consequently, the ratio of oxygen supply and demand to myocardium (endocardial viability ratio, EVR) increased between 33% and 75%. The increase was mostly attributed to diastolic augmentation rather than systolic unloading.