12 resultados para Pons

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a novel Rayleigh interferometric noise mitigation scheme for applications in carrier-distributed dense wavelength division multiplexed (DWDM) passive optical networks at 10 Gbit/s using carrier suppressed subcarrier-amplitude modulated phase shift keying modulation. The required optical signal to Rayleigh noise ratio is reduced by 12 dB, while achieving excellent tolerance to dispersion, subcarrier frequency and drive amplitude variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel modulator array integrating eight GaAs electro-optic IQ modulators is characterized and tested over long-reach direct-detected multi-band OFDM-PONs. The GaAs IQ modulators present > 22 GHz bandwidth with 3V Vpi, being suitable for a 100-km 40-Gb/s OOFDM-PON supporting up to 1024 users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The peak-to-average power ratio (PAPR) and optical beat interference (OBI) effects are examined thoroughly in orthogonal frequency-division multiplexing access (OFDMA)-passive optical networks (PONs) at a signal bit rate up to ∼ 20 Gb/s per channel using cost-effective intensity-modulation and direct-detection (IM/DD). Single-channel OOFDM and upstream multichannel OFDM-PONs are investigated for up to six users. A number of techniques for mitigating the PAPR and OBI effects are presented and evaluated including adaptive-loading algorithms such as bit/power-loading, clipping for PAPR reduction, and thermal detuning (TD) for the OBI suppression. It is shown that the bit-loading algorithm is a very efficient PAPR reduction technique by reducing it at about 1.2 dB over 100 Km of transmission. It is also revealed that the optimum method for suppressing the OBI is the TD + bit-loading. For a targeted BER of 1 × 10-3, the minimum allowed channel spacing is 11 GHz when employing six users. © 2013 Springer Science+Business Media New York.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show 100-Gb/s single-channel transmission in LR-PONs with at least 512 way split and up to 160 km total distance is feasible by means of "chained" cable with amplifier solutions, and appropriate FIR filter designs. © 2015 OSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To determine in the cerebellum in variant Creutzfeldt–Jakob disease (vCJD): (i) whether the pathology affected all laminae; (ii) the spatial topography of the pathology along the folia; (iii) spatial correlations between the pathological changes; and (iv) whether the pathology was similar to that of the common methionine/methionine Type 1 subtype of sporadic CJD. Methods: Sequential cerebellar sections of 15 cases of vCJD were stained with haematoxylin and eosin, or immunolabelled with monoclonal antibody 12F10 against prion protein (PrP) and studied using spatial pattern analysis. Results: Loss of Purkinje cells was evident compared with control cases. Densities of the vacuolation and the protease-resistant form of prion protein (PrPSc) (diffuse and florid plaques) were greater in the granule cell layer (GL) than the molecular layer (ML). In the ML, vacuoles and PrPSc plaques occurred in clusters regularly distributed along the folia with larger clusters of vacuoles and diffuse plaques in the GL. There was a negative spatial correlation between the vacuoles and the surviving Purkinje cells in the ML. There was a positive spatial correlation between the vacuoles and diffuse PrPSc plaques in the ML and GL. Conclusions: (i) all laminae were affected by the pathology, the GL more severely than the ML; (ii) the pathology was topographically distributed along the folia especially in the Purkinje cell layer and ML; (iii) pathological spread may occur in relation to the loop of anatomical connections involving the cerebellum, thalamus, cerebral cortex and pons; and (iv) there were pathological differences compared with methionine/methionine Type 1 sporadic CJD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In eight cases of progressive supranuclear palsy (PSP), neurofibrillary tangles (NFT) were numerous in the substantia nigra (SN), red nucleus (RN), locus caeruleus (LC), pontine nuclei (PN), and inferior olivary nucleus (ION) and abnormally enlarged neurons (EN) in the ION, LC and PN. Loss of Purkinje cells was evident in the cerebellum. Tufted astrocytes (TA) were abundant in the striatum, SN and RN and glial inclusions ('coiled bodies') (GI) in the midbrain (SN, RN) and pons (LC). Neuritic plaques were frequent in one case. NFT, GI, and TA densities were uncorrelated in most areas. NFT and EN densities were positively correlated in the midbrain and surviving neurons and disease duration in several areas. These results suggest: 1) predominantly subcortical pathology in PSP with widespread NFT while TA and GI have a more localized distribution, 2) little correlation between neuronal and glial pathologies, and 3) shorter duration cases may be more likely to develop cortical pathology. © 2007 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The density and spatial distribution of the vacuoles, glial cell nuclei and glial cytoplasmic inclusions (GCI) were studied in the white matter of various cortical and subcortical areas in 10 cases of multiple system atrophy (MSA). Vacuolation was more prevalent in subcortical than cortical areas and especially in the central tegmental tract. Glial cell nuclei widespread in all areas of the white matter studied; overall densities of glial cell nuclei being significantly greater in the central tegmental tract and frontal cortex compared with areas of the pons. The GCI were present most consistently in the external and internal capsules, the central tegmental tract and the white matter of the cerebellar cortex. The density of the vacuoles was greater in the MSA brains than in the control brains but glial cell density was similar in both groups. In the majority of areas, the pathological changes were distributed across the white matter randomly, uniformly, or in large diffuse clusters. In most areas, there were no spatial correlations between the vacuoles, glial cell nuclei and GCI. These results suggest: (i) there is significant degeneration of the white matter in MSA characterized by vacuolation and GCI; (ii) the central tegmental tract is affected significantly more than the cortical tracts; (iii) pathological changes are diffusely rather than topographically distributed across the white matter; and (iv) the development of the vacuoles and GCI appear to be unrelated phenomena. © 2007 Japanese Society of Neuropathology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The densities of the glial cytoplasmic inclusions (GCI), neuronal inclusions (NI), and abnormal neurons were studied in the frontal cortex, hippocampus, cerebellum, basal ganglia and areas of the pons and medulla in 10 cases of multiple system atrophy (MSA). GCI density was greater in the substantia nigra and globus pallidus compared with the frontal cortex and hippocampus. Abnormal neurons were most abundant in the frontal cortex, substantia nigra, and inferior olivary nucleus. NI and abnormal neuron densities were positively correlated in the globus pallidus but negatively correlated in the hippocampus. The NI and GCI were only positively correlated in the pons. GCI in the pons and inferior olivary nucleus, NI in the substantia nigra, and abnormal neurons in the frontal cortex varied significantly between cases. The MSA cases did not cluster according to disease subtype. The data suggest that: 1) the greatest densities of pathological changes occur in the substantia nigra and globus pallidus, 2) density of the GCI is unrelated to that of the NI, and 3) there is overlapping pathology between the various subtypes of MSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this chapter is to quantify the neuropathology of the cerebellar cortex in cases of the prion disease variant Creutzfeldt-Jakob disease (vCJD). Hence, sequential sections of the cerebellum of 15 cases of vCJD were stained with H/E, or immunolabelled with a monoclonal antibody 12F10 against prion protein (PrP) and studied using quantitative techniques and spatial pattern analysis. A significant loss of Purkinje cells was evident in all cases. Densities of the vacuolation and the protease resistant form of prion protein (PrPSc) in the form of diffuse and florid plaques were greater in the granule cell layer (GL) than the molecular layer (ML). In the ML, vacuoles and PrPSc plaques, occurred in clusters which were regularly distributed along the folia, larger clusters of vacuoles and diffuse plaques being present in the GL. There was a negative spatial correlation between the vacuoles and the surviving Purkinje cells in the ML and a positive spatial correlation between the clusters of vacuoles and the diffuse PrPSc plaques in the ML and GL in five and six cases respectively. A canonical variate analysis (CVA) suggested a negative correlation between the densities of the vacuolation in the GL and the diffuse PrPSc plaques in the ML. The data suggest: 1) all laminae of the cerebellar cortex were affected by the pathology of vCJD, the GL more severely than the ML, 2) the pathology was topographically distributed especially in the Purkinje cell layer and GL, 3) pathological spread may occur in relation to a loop of anatomical projections connecting the cerebellum, thalamus, cerebral cortex, and pons, and 4) there are differences in the pathology of the cerebellum in vCJD compared with the M/M1 subtype of sporadic CJD (sCJD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Geospatial data have become a crucial input for the scientific community for understanding the environment and developing environmental management policies. The Global Earth Observation System of Systems (GEOSS) Clearinghouse is a catalogue and search engine that provides access to the Earth Observation metadata. However, metadata are often not easily understood by users, especially when presented in ISO XML encoding. Data quality included in the metadata is basic for users to select datasets suitable for them. This work aims to help users to understand the quality information held in metadata records and to provide the results to geospatial users in an understandable and comparable way. Thus, we have developed an enhanced tool (Rubric-Q) for visually assessing the metadata quality information and quantifying the degree of metadata population. Rubric-Q is an extension of a previous NOAA Rubric tool used as a metadata training and improvement instrument. The paper also presents a thorough assessment of the quality information by applying the Rubric-Q to all dataset metadata records available in the GEOSS Clearinghouse. The results reveal that just 8.7% of the datasets have some quality element described in the metadata, 63.4% have some lineage element documented, and merely 1.2% has some usage element described. © 2013 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When combining remote sensing imagery with statistical classifiers to obtain categorical thematic maps it is not usual to provide data about the spatial distribution of the error and uncertainty of the resulting maps. This paper describes, in the context of GeoViQua FP7 project, feasible approaches for methods based on several steps such as hybrid classifiers. Both for “per pixel” and “per polygon” strategies, the proposal is based on the use of the available ground truth, which is used to properly model the spatial distribution of the errors. Results allow mapping the classification success with a very high level of reliability (R2>0,94), providing users a sound knowledge of the accuracy at every area of the map.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extensive numerical investigations are undertaken to analyze and compare, for the first time, the performance, techno-economy, and power consumption of three-level electrical Duobinary, optical Duobinary, and PAM-4 modulation formats as candidates for high-speed next-generation PONs supporting downstream 40 Gb/s per wavelength signal transmission over standard SMFs in C-band. Optimization of transceiver bandwidths are undertaken to show the feasibility of utilizing low-cost and band-limited components to support next-generation PON transmissions. The effect of electro-absorption modulator chirp is examined for electrical Duobinary and PAM-4. Electrical Duobinary and optical Duobinary are powerefficient schemes for smaller transmission distances of 10 km SMFs and optical Duobinary offers the best receiver sensitivity albeit with a relatively high transceiver cost. PAM-4 shows the best power budget and costefficiency for larger distances of around 20 km, although it consumes more power. Electrical Duobinary shows the best trade-off between performance, cost and power dissipation.