5 resultados para Physical ability

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transglutaminases have the ability to incorporate primary amines and to graft peptides (containing glutamine or lysine residues) into proteins. These properties enable transglutaminases to be used in the grafting of a range of compounds including peptides and/or proteins onto wool fibres, altering their functionality. In this paper we investigated the transglutaminase mediated grafting of silk proteins into wool and its effect on wool properties. A commercial hydrolysed silk preparation was compared with silk sericin. The silk sericin protein was labelled with a fluorescent probe which was used to demonstrate the efficiency of the TGase grafting of such proteins into wool fibres. The TGase mediated grafting of these proteins led to a significant effect on the properties of wool yarn and fabric, resulting in increased bursting strength, as well as reduced levels of felting shrinkage and improved fabric softness. Also observed was an accumulation of deposits on the surface of the treated wool fibres when monitored by SEM and alterations in the thermal behaviour of the modified fibres, in particular for mTGase/sericin treated fibres which, with the confocal studies, corroborate the physical changes observed on the treated wool fabric. © 2006 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research investigates technology transfer (TT) to developing countries, with specific reference to South Africa. Particular attention is paid to physical asset management, which includes the maintenance of plant, equipment and facilities. The research is case based, comprising a main case study (the South African electricity utility, Eskom) and four mini-cases. A five level framework adapted from Salami and Reavill (1997) is used as the methodological basis for the formulation of the research questions. This deals with technology selection, and management issues including implementation and maintenance and evaluation and modifications. The findings suggest the Salami and Reavill (1997) framework is a useful guide for TT. The case organisations did not introduce technology for strategic advantage, but to achieve operational efficiencies through cost reduction, higher quality and the ability to meet customer demand. Acquirers favour standardised technologies with which they are familiar. Cost-benefit evaluations have limited use in technology acquisition decisions. Users rely on supplier expertise to compensate for poor education and technical training in South Africa. The impact of political and economic factors is more evident in Eskom than in the mini-cases. Physical asset management follows traditional preventive maintenance practices, with limited use of new maintenance management thinking. Few modifications of the technology or R&D innovations take place. Little use is made of explicit knowledge from computerised maintenance management systems. Low operating and maintenance skills are not conducive to the transfer of high-technology equipment. South African organisations acquire technology as items of plant, equipment and systems, but limited transfer of technology takes place. This suggests that operators and maintainers frequently do not understand the underlying technology, and like workers elsewhere, are not always inclined towards adopting technology in the workplace.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Humans consciously and subconsciously establish various links, emerge semantic images and reason in mind, learn linking effect and rules, select linked individuals to interact, and form closed loops through links while co-experiencing in multiple spaces in lifetime. Machines are limited in these abilities although various graph-based models have been used to link resources in the cyber space. The following are fundamental limitations of machine intelligence: (1) machines know few links and rules in the physical space, physiological space, psychological space, socio space and mental space, so it is not realistic to expect machines to discover laws and solve problems in these spaces; and, (2) machines can only process pre-designed algorithms and data structures in the cyber space. They are limited in ability to go beyond the cyber space, to learn linking rules, to know the effect of linking, and to explain computing results according to physical, physiological, psychological and socio laws. Linking various spaces will create a complex space — the Cyber-Physical-Physiological-Psychological-Socio-Mental Environment CP3SME. Diverse spaces will emerge, evolve, compete and cooperate with each other to extend machine intelligence and human intelligence. From multi-disciplinary perspective, this paper reviews previous ideas on various links, introduces the concept of cyber-physical society, proposes the ideal of the CP3SME including its definition, characteristics, and multi-disciplinary revolution, and explores the methodology of linking through spaces for cyber-physical-socio intelligence. The methodology includes new models, principles, mechanisms, scientific issues, and philosophical explanation. The CP3SME aims at an ideal environment for humans to live and work. Exploration will go beyond previous ideals on intelligence and computing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: to determine the effect of drugs with anti-cholinergic properties on relevant health outcomes.Design: electronic published and unpublished literature/trial registries were systematically reviewed. Studies evaluating medications with anti-cholinergic activity on cognitive function, delirium, physical function or mortality were eligible.Results: forty-six studies including 60,944 participants were included. Seventy-seven percent of included studies evaluating cognitive function (n = 33) reported a significant decline in cognitive ability with increasing anti-cholinergic load (P < 0.05). Four of five included studies reported no association with delirium and increasing anti-cholinergic drug load (P > 0.05). Five of the eight included studies reported a decline in physical function in users of anti-cholinergics (P < 0.05). Three of nine studies evaluating mortality reported that the use of drugs with anti-cholinergic properties was associated with a trend towards increased mortality, but this was not statistically significant. The methodological quality of the evidence-base ranged from poor to very good.Conclusion: medicines with anti-cholinergic properties have a significant adverse effect on cognitive and physical function, but limited evidence exists for delirium or mortality outcomes. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the adhesive properties of an in-house amino-propyltrimethoxysilane-methylenebisacrylamide (APTMS-MBA) siloxane system and compare them with a commercially available adhesive, n-butyl cyanoacrylate (nBCA). The ability of the material to perform as a soft tissue adhesive was established by measuring the physical (bond strength, curing time) and biological (cytotoxicity) properties of the adhesives on cartilage. Complementary physical techniques, X-ray photoelectron spectroscopy, Raman and infrared imaging, enabled the mode of action of the adhesive to the cartilage surface to be determined. Adhesion strength to cartilage was measured using a simple butt joint test after storage in phosphate-buffered saline solution at 37°C for periods up to 1 month. The adhesives were also characterised using two in vitro biological techniques. A live/dead stain assay enabled a measure of the viability of chondrocytes attached to the two adhesives to be made. A water-soluble tetrazolium assay was carried out using two different cell types, human dermal fibroblasts and ovine meniscal chondrocytes, in order to measure material cytotoxicity as a function of both supernatant concentration and time. IR imaging of the surface of cartilage treated with APTMS-MBA siloxane adhesive indicated that the adhesive penetrated the tissue surface marginally compared to nBCA which showed a greater depth of penetration. The curing time and adhesion strength values for APTMS-MBA siloxane and nBCA adhesives were measured to be 60 s/0.23 MPa and 38 min/0.62 MPa, respectively. These materials were found to be significantly stronger than either commercially available fibrin (0.02 MPa) or gelatin resorcinol formaldehyde (GRF) adhesives (0.1 MPa) (P <0.01). Cell culture experiments revealed that APTMS-MBA siloxane adhesive induced 2% cell death compared to 95% for the nBCA adhesive, which extended to a depth of approximately 100-150 μm into the cartilage surface. The WST-1 assay demonstrated that APTMS-MBA siloxane was significantly less cytotoxic than nBCA adhesive as an undiluted conditioned supernatant (P <0.001). These results suggest that the APTMS-MBA siloxane may be a useful adhesive for medical applications. © VSP 2005.