7 resultados para Phasor Measurement Unit

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research develops a low cost remote sensing system for use in agricultural applications. The important features of the system are that it monitors the near infrared and it incorporates position and attitude measuring equipment allowing for geo-rectified images to be produced without the use of ground control points. The equipment is designed to be hand held and hence requires no structural modification to the aircraft. The portable remote sensing system consists of an inertia measurement unit (IMU), which is accelerometer based, a low-cost GPS device and a small format false colour composite digital camera. The total cost of producing such a system is below GBP 3000, which is far cheaper than equivalent existing systems. The design of the portable remote sensing device has eliminated bore sight misalignment errors from the direct geo-referencing process. A new processing technique has been introduced for the data obtained from these low-cost devices, and it is found that using this technique the image can be matched (overlaid) onto Ordnance Survey Master Maps at an accuracy compatible with precision agriculture requirements. The direct geo-referencing has also been improved by introducing an algorithm capable of correcting oblique images directly. This algorithm alters the pixels value, hence it is advised that image analysis is performed before image georectification. The drawback of this research is that the low-cost GPS device experienced bad checksum errors, which resulted in missing data. The Wide Area Augmented System (WAAS) correction could not be employed because the satellites could not be locked onto whilst flying. The best GPS data were obtained from the Garmin eTrex (15 m kinematic and 2 m static) instruments which have a highsensitivity receiver with good lock on capability. The limitation of this GPS device is the inability to effectively receive the P-Code wavelength, which is needed to gain the best accuracy when undertaking differential GPS processing. Pairing the carrier phase L1 with the pseudorange C/A-Code received, in order to determine the image coordinates by the differential technique, is still under investigation. To improve the position accuracy, it is recommended that a GPS base station should be established near the survey area, instead of using a permanent GPS base station established by the Ordnance Survey.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Intensive Care Unit (ICU) being one of those vital areas of a hospital providing clinical care, the quality of service rendered must be monitored and measured quantitatively. It is, therefore, essential to know the performance of an ICU, in order to identify any deficits and enable the service providers to improve the quality of service. Although there have been many attempts to do this with the help of illness severity scoring systems, the relative lack of success using these methods has led to the search for a form of measurement, which would encompass all the different aspects of an ICU in a holistic manner. The Analytic Hierarchy Process (AHP), a multiple-attribute, decision-making technique is utilised in this study to evolve a system to measure the performance of ICU services reliably. This tool has been applied to a surgical ICU in Barbados; we recommend AHP as a valuable tool to quantify the performance of an ICU. Copyright © 2004 Inderscience Enterprises Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whereas the competitive advantage of firms can arise from size and position within their industry as well as physical assets, the pattern of competition in advanced economies has increasingly come to favour those firms that can mobilise knowledge and technological skills to create novelty in their products. At the same time, regions are attracting growing attention as an economic unit of analysis, with firms increasingly locating their functions in select regions within the global space. This article introduces the concept of knowledge competitiveness, defined as an economy’s knowledge capacity, capability and sustainability, and the extent to which this knowledge is translated into economic value and transferred into the wealth of the citizens. The article discusses the way in which the knowledge competitiveness of regions is measured and further introduces the World Knowledge Competitiveness Index, which is the first composite and relative measure of the knowledge competitiveness of the globe’s best performing regions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A microchannel was inscribed in the fiber of a ring cavity which was constructed using two 0.1%:99.9% couplers and a 10-m fiber loop. Cavity ring down spectroscopy was used to measure the refractive index (RI) of gels infused into the microchannel. The ring down time discloses a nonlinear increase with respect to RI of the gel and sensitivity up to 300 µs/RI unit and an index resolution of 1.4 × 10 was obtained. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Off-highway motive plant equipment is costly in capital outlay and maintenance. To reduce these overheads and increase site safety and workrate, a technique of assessing and limiting the velocity of such equipment is required. Due to the extreme environmental conditions met on such sites, conventional velocity measurement techniques are inappropriate. Ogden Electronics Limited were formed specifically to manufacture a motive plant safety system incorporating a speed sensor and sanction unit; to date, the only such commercial unit available. However, problems plague the reliability, accuracy and mass production of this unit. This project assesses the company's exisiting product, and in conjunction with an appreciation of the company history and structure, concludes that this unit is unsuited to its intended application. Means of improving the measurement accuracy and longevity of this unit, commensurate with the company's limited resources and experience, are proposed, both for immediate retrofit and for longer term use. This information is presented in the form of a number of internal reports for the company. The off-highway environment is examined; and in conjunction with an evaluation of means of obtaining a returned signal, comparisons of processing techniques, and on-site gathering of previously unavailable data, preliminary designs for an alternative product are drafted. Theoretical aspects are covered by a literature review of ground-pointing radar, vehicular radar, and velocity measuring systems. This review establishes and collates the body of knowledge in areas previously considered unrelated. Based upon this work, a new design is proposed which is suitable for incorporation into the existing company product range. Following production engineering of the design, five units were constructed, tested and evaluated on-site. After extended field trials, this design has shown itself to possess greater accuracy, reliability and versatility than the existing sensor, at a lower unit cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A microchannel was inscribed in the fiber of a ring cavity which was constructed using two 0.1%:99.9% couplers and a 10-m fiber loop. Cavity ring down spectroscopy was used to measure the refractive index (RI) of gels infused into the microchannel. The ring down time discloses a nonlinear increase with respect to RI of the gel and sensitivity up to 300 µs/RI unit and an index resolution of 1.4 × 10 was obtained. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple fiber sensor capable of simultaneous measurement of liquid level and refractive index (RI) is proposed and experimentally demonstrated. The sensing head is an all-fiber modal interferometer manufactured by splicing an uncoated single-mode fiber with two short sections of multimode fiber. The interference pattern experiences blue shift along with an increase of axial strain and surrounding RI. Owing to the participation of multiple cladding modes with different sensitivities, the height and RI of the liquid could be simultaneously measured by monitoring two dips of the transmission spectrum. Experimental results show that the liquid level and RI sensitivities of the two dips are 245.7 pm/mm, -38 nm/RI unit (RIU), and 223.7 pm/mm, -62 nm/RIU, respectively. The approach has distinctive advantages of easy fabrication, low cost, and high sensitivity for liquid level detection with the capability of distinguishing the RI variation simultaneously. © 2013 Copyright Taylor and Francis Group, LLC.