9 resultados para Parametric Linear System

em Aston University Research Archive


Relevância:

90.00% 90.00%

Publicador:

Resumo:

We compare the Q parameter obtained from the semi-analytical model with scalar and vector models for two realistic transmission systems. First a linear system with a compensated dispersion map and second a soliton transmission system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Over 60% of the recurrent budget of the Ministry of Health (MoH) in Angola is spent on the operations of the fixed health care facilities (health centres plus hospitals). However, to date, no study has been attempted to investigate how efficiently those resources are used to produce health services. Therefore the objectives of this study were to assess the technical efficiency of public municipal hospitals in Angola; assess changes in productivity over time with a view to analyzing changes in efficiency and technology; and demonstrate how the results can be used in the pursuit of the public health objective of promoting efficiency in the use of health resources. The analysis was based on a 3-year panel data from all the 28 public municipal hospitals in Angola. Data Envelopment Analysis (DEA), a non-parametric linear programming approach, was employed to assess the technical and scale efficiency and productivity change over time using Malmquist index.The results show that on average, productivity of municipal hospitals in Angola increased by 4.5% over the period 2000-2002; that growth was due to improvements in efficiency rather than innovation. © 2008 Springer Science+Business Media, LLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In May 2006, the Ministers of Health of all the countries on the African continent, at a special session of the African Union, undertook to institutionalise efficiency monitoring within their respective national health information management systems. The specific objectives of this study were: (i) to assess the technical efficiency of National Health Systems (NHSs) of African countries for measuring male and female life expectancies, and (ii) to assess changes in health productivity over time with a view to analysing changes in efficiency and changes in technology. The analysis was based on a five-year panel data (1999-2003) from all the 53 countries of continental Africa. Data Envelopment Analysis (DEA) - a non-parametric linear programming approach - was employed to assess the technical efficiency. Malmquist Total Factor Productivity (MTFP) was used to analyse efficiency and productivity change over time among the 53 countries' national health systems. The data consisted of two outputs (male and female life expectancies) and two inputs (per capital total health expenditure and adult literacy). The DEA revealed that 49 (92.5%) countries' NHSs were run inefficiently in 1999 and 2000; 50 (94.3%), 48 (90.6%) and 47 (88.7%) operated inefficiently in 2001, 2002, and 2003 respectively. All the 53 countries' national health systems registered improvements in total factor productivity attributable mainly to technical progress. Fifty-two countries did not experience any change in scale efficiency, while thirty (56.6%) countries' national health systems had a Pure Efficiency Change (PEFFCH) index of less than one, signifying that those countries' NHSs pure efficiency contributed negatively to productivity change. All the 53 countries' national health systems registered improvements in total factor productivity, attributable mainly to technical progress. Over half of the countries' national health systems had a pure efficiency index of less than one, signifying that those countries' NHSs pure efficiency contributed negatively to productivity change. African countries may need to critically evaluate the utility of institutionalising Malmquist TFP type of analyses to monitor changes in health systems economic efficiency and productivity over time. African national health systems, per capita total health expenditure, technical efficiency, scale efficiency, Malmquist indices of productivity change, DEA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We demonstrate second harmonic generation at 1621 nm in a low-loss orientation-patterned GaAs waveguide pumped by an optical parametric oscillator system. The losses were estimated to be 2.12 dB/cm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many of the recent improvements in the capacity of data cartridge systems have been achieved through the use of narrower tracks, higher linear densities and continuous servo tracking with multi-channel heads. These changes have produced new tribological problems at the head/tape interface. It is crucial that the tribology of such systems is understood and this will continue since increasing storage capacities and faster transfer rates are constantly being sought. Chemical changes in the surface of single and dual layer MP tape have been correlated to signal performance. An accelerated tape tester, consisting of a custom made cycler ("loop tester"), was used to ascertain if results could be produced that were representative of a real tape drive system. A second set of experiments used a modified tape drive (Georgens cycler), which allowed the effects of the tape transport system on the tape surface to be studied. To isolate any effects on the tape surface due to the head/tape interface, read/write heads were not fitted to the cycler. Two further sets of experiments were conducted which included a head in the tape path. This allowed the effects of the head/tape interface on the physical and chemical properties of the head and tape surfaces to be investigated. It was during the final set of experiments that the effect on the head/tape interface, of an energised MR element, was investigated. The effect of operating each cycler at extreme relative humidity and temperature was investigated through the use of an environmental chamber. Extensive use was made of surface specific analytical techniques such as XPS, AFM, AES, and SEM to study the physical and chemical changes that occur at the head/tape interface. Results showed that cycling improved the signal performance of all the tapes tested. The data cartridge drive belt had an effect on the chemical properties of the tape surface on which it was in contact. Also binder degradation occurred for each tape and appeared to be greater at higher humidity. Lubricant was generally seen to migrate to the tape surface with cycling. Any surface changes likely to affect signal output occurred at the head surface rather than the tape.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It is shown that regimes with dynamical chaos are inherent not only to nonlinear system but they can be generated by initially linear systems and the requirements for chaotic dynamics and characteristics need further elaboration. Three simplest physical models are considered as examples. In the first, dynamic chaos in the interaction of three linear oscillators is investigated. Analogous process is shown in the second model of electromagnetic wave scattering in a double periodical inhomogeneous medium occupying half-space. The third model is a linear parametric problem for the electromagnetic field in homogeneous dielectric medium which permittivity is modulated in time. © 2008 Springer Science+Business Media, LLC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Methods of dynamic modelling and analysis of structures, for example the finite element method, are well developed. However, it is generally agreed that accurate modelling of complex structures is difficult and for critical applications it is necessary to validate or update the theoretical models using data measured from actual structures. The techniques of identifying the parameters of linear dynamic models using Vibration test data have attracted considerable interest recently. However, no method has received a general acceptance due to a number of difficulties. These difficulties are mainly due to (i) Incomplete number of Vibration modes that can be excited and measured, (ii) Incomplete number of coordinates that can be measured, (iii) Inaccuracy in the experimental data (iv) Inaccuracy in the model structure. This thesis reports on a new approach to update the parameters of a finite element model as well as a lumped parameter model with a diagonal mass matrix. The structure and its theoretical model are equally perturbed by adding mass or stiffness and the incomplete number of eigen-data is measured. The parameters are then identified by an iterative updating of the initial estimates, by sensitivity analysis, using eigenvalues or both eigenvalues and eigenvectors of the structure before and after perturbation. It is shown that with a suitable choice of the perturbing coordinates exact parameters can be identified if the data and the model structure are exact. The theoretical basis of the technique is presented. To cope with measurement errors and possible inaccuracies in the model structure, a well known Bayesian approach is used to minimize the least squares difference between the updated and the initial parameters. The eigen-data of the structure with added mass or stiffness is also determined using the frequency response data of the unmodified structure by a structural modification technique. Thus, mass or stiffness do not have to be added physically. The mass-stiffness addition technique is demonstrated by simulation examples and Laboratory experiments on beams and an H-frame.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have reduced signal-signal four-wave mixing crosstalk in a fiber optical parametric amplifier (OPA) by using a short nonlinear fiber for the gain medium and a high-power pump. This allowed us to obtain less than 1 dB penalty for amplification of 26 dense wavelength-division multiplexed (WDM) channels modulated at 43.7Gb/s return to zero-differential phase-shift keying, with the OPA placed between transmitter and receiver. We then used the same OPA in several different roles for a long-haul transmission system. We did not insert the OPA within the loop, but investigated this role indirectly by using equivalent results for small numbers of loop recirculations. We found that standard erbium-doped fiber amplifiers currently hold an advantage over this OPA, which becomes negligible for long distances. This paper shows that at this time OPAs can handle amplification of WDM traffic in excess of 1 Tb/s with little degradation. It also indicates that with further improvements, fiber OPAs could be a contender for wideband amplification in future optical communication networks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, two linear coplanar array antennas based on Indium Phosphide (InP) substrate are designed, presented and compared in terms of bandwidth and gain. Slot introduction in combination with coplanar structure is investigated, providing enhanced antenna gain and bandwidth at the 60 GHz frequency band. In addition the proposed array antennas are evaluated in terms of integration with a high-speed photodiode and investigated in terms of matching, providing a bandwidth that reaches 2 GHz. Moreover a potential beam forming scenario combined with photonic up-conversion scheme has been proposed. © 2013 IEEE.