7 resultados para Pap Test Screening

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Age-related macular degeneration (ARMD) is the leading cause of visual disability in people over 60 years of age in the developed world. The success of treatment deteriorates with increased latency of diagnosis. The purpose of this study was to determine the reliability of the macular mapping test (MMT), and to investigate its potential as a screening tool. Methods: The study population comprised of 31 healthy eyes of 31 participants. To assess reliability, four macular mapping test (MMT) measurements were taken in two sessions separated by one hour by two practitioners, with reversal of order in the second session. MMT readings were also taken from 17 age-related maculopathy (ARM), and 12 AMD affected eyes. Results: For the normal cohort, average MMT scores ranged from 85.5 to 100.0 MMT points. Scores ranged from 79.0 to 99.0 for the ARM group and from 9.0 to 92.0 for the AMD group. MMT scores were reliable to within ± 7.0 points. The difference between AMD affected eyes and controls (z = 3.761, p = < 0.001) was significant. The difference between ARM affected eyes and controls was not significant (z = -0.216, p = 0.829). Conclusion: The reliability data shows that a change of 14 points or more is required to indicate a clinically significant change. This value is required for use of the MMT as an outcome measure in clinical trials. Although there was no difference between MMT scores from ARM affected eyes and controls, the MMT has the advantage over the Amsler grid in that it uses a letter target, has a peripheral fixation aid, and it provides a numerical score. This score could be beneficial in office and home monitoring of AMD progression, as well as an outcome measure in clinical research. © 2005 Bartlett et al; licensee BioMed Central Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Meta-analysis was used to quantify how well the Theories of Reasoned Action and Planned Behaviour have predicted intentions to attend screening programmes and actual attendance behaviour. Systematic literature searches identified 33 studies that were included in the review. Across the studies as a whole, attitudes had a large-sized relationship with intention, while subjective norms and perceived behavioural control (PBC) possessed medium-sized relationships with intention. Intention had a medium-sized relationship with attendance, whereas the PBC-attendance relationship was small sized. Due to heterogeneity in results between studies, moderator analyses were conducted. The moderator variables were (a) type of screening test, (b) location of recruitment, (c) screening cost and (d) invitation to screen. All moderators affected theory of planned behaviour relationships. Suggestions for future research emerging from these results include targeting attitudes to promote intention to screen, a greater use of implementation intentions in screening information and examining the credibility of different screening providers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the accuracy and acceptability of polymerase chain reaction (PCR) and optical immunoassay (OIA) tests for the detection of maternal group B streptococcus (GBS) colonisation during labour, comparing their performance with the current UK policy of risk factor-based screening. Design Diagnostic test accuracy study. Setting and population Fourteen hundred women in labour at two large UK maternity units provided vaginal and rectal swabs for testing. Methods The PCR and OIA index tests were compared with the reference standard of selective enriched culture, assessed blind to index tests. Factors influencing neonatal GBS colonisation were assessed using multiple logistic regression, adjusting for antibiotic use. The acceptability of testing to participants was evaluated through a structured questionnaire administered after delivery. Main outcome measures The sensitivity and specificity of PCR, OIA and risk factor-based screening. Results Maternal GBS colonisation was 21% (19-24%) by combined vaginal and rectal swab enriched culture. PCR test of either vaginal or rectal swabs was more sensitive (84% [79-88%] versus 72% [65-77%]) and specific (87% [85-89%] versus 57% [53-60%]) than OIA (P <0.001), and far more sensitive (84 versus 30% [25-35%]) and specific (87 versus 80% [77-82%]) than risk factor-based screening (P <0.001). Maternal antibiotics (odds ratio, 0.22 [0.07-0.62]; P = 0.004) and a positive PCR test (odds ratio, 29.4 [15.8-54.8]; P <0.001) were strongly related to neonatal GBS colonisation, whereas risk factors were not (odds ratio, 1.44 [0.80-2.62]; P = 0.2). Conclusion Intrapartum PCR screening is a more accurate predictor of maternal and neonatal GBS colonisation than is OIA or risk factor-based screening, and is acceptable to women. © RCOG 2010 BJOG An International Journal of Obstetrics and Gynaecology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Self-testing technology allows people to test themselves for chlamydia without professional support. This may result in reassurance and wider access to chlamydia testing, but anxiety could occur on receipt of positive results. This study aimed to identify factors important in understanding self-testing for chlamydia outside formal screening contexts, to explore the potential impacts of self-testing on individuals, and to identify theoretical constructs to form a Framework for future research and intervention development. Methods: Eighteen university students participated in semi-structured interviews; eleven had self-tested for chlamydia. Data were analysed thematically using a Framework approach. Results: Perceived benefits of self-testing included its being convenient, anonymous and not requiring physical examination. There was concern about test accuracy and some participants lacked confidence in using vulvo-vaginal swabs. While some participants expressed concern about the absence of professional support, all said they would seek help on receiving a positive result. Factors identified in Protection Motivation Theory and the Theory of Planned Behaviour, such as response efficacy and self-efficacy, were found to be highly salient to participants in thinking about self-testing. Conclusions: These exploratory findings suggest that self-testing independently of formal health care systems may no more negatively impact people than being tested by health care professionals. Participants’ perceptions about self-testing behaviour were consistent with psychological theories. Findings suggest that interventions which increase confidence in using self-tests and that provide reassurance of test accuracy may increase self-test intentions.