8 resultados para PYROLYTIC-GRAPHITE ELECTRODE

em Aston University Research Archive


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The electrocopolymerization of carbazole and acrylamide on highly oriented pyrolytic graphite (HOPG) from ACN solutions via cyclovoltammetry (CV) was studied in order to evaluate the possibility to deposit uniform and thin but pinhole-free and still reactive coatings onto graphite-like substrates. The morphology of the coatings was investigated using atomic force microscopy and the coating thicknesses and optical parameters were measured using ellipsometry. It was found that under the chosen conditions thin (coating thickness hf>180 nm) and relatively smooth (root mean square surface roughness RMS<150 nm) P(Cz-co-AAm)-coatings exhibiting a uniform globuoidal morphology can be deposited onto graphite. From a certain coating thickness (hf>50 nm) no pinholes could be detected. It was found that the thickness of the deposited coatings increases almost linearly with increasing number of CV-cycles while keeping all other experimental parameters (scan rate and comonomer concentration ratio) constant. No influence of the comonomer concentration ratio on the film thickness and coating appearance could be observed, however, at quite low initial concentrations. However, the CV-scanning rate has quite a significant influence on the thickness of the deposited coatings. Higher scan rates (100 mV/s) result in thin (hf≈22 nm) coatings whereas at lower scan rates (<50 mV/s) coatings with thicknesses of approximately 50 nm were obtained. The optical coating parameters (the refractive index n and extinction coefficient k) seem to be independent of the deposition parameters and therefore averaged values of n̄=1.54±0.03 and k̄=0.08±0.03 were obtained.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The development of reliable, high powered plasma generators has resulted in many plasma processes being proposed as alternatives to existing pyrometallurgical technologies. This work evaluates the advantages and disadvantages of plasma systems by reviewing plasma generators, their integration with reactors and the process economics. Many plasma systems were shown to be technically and economically superior to existing technologies, but some of the plasma system advantages quoted in the literature were found to be impractical because of other system constraints. Process applications were limited by the power inputs available from plasma generators compared to AC electric furnaces. A series of trials were conducted where chromite and steelplant baghouse dusts were smelted in the Tetronics' 2.0 MW transferred arc/open bath reactor to confirm the operating characteristics of the plasma system and its economics. Chromite smelting was technical superior to submerged arc furnace technology, but the economics were unfavourable because of the limited power available from the water-cooled plasma torch and the high electrical energy consumption. A DC graphite electrode plasma furnace using preheated and prereduced chromite concentrates will compete economically with the submerged arc furnace. Ni, Cr and Mo were economically recovered from high alloy content steelplant dusts for recycling. Five Electric Arc Furnace dusts were smelted to produce a non-toxic residue and recover the contained zinc to an enriched zinc oxide product for recycling. It should be possible to condense the zinc vapour directly in a zinc splash condenser to increase the value of the product. Because of the limited power available from plasma generators, plasma processes will be most suitable for treating high and medium value materials such as Au, Pt, Mo, Ni, Ti, V, Cr etc at small production rates, heating metals in tundishes and ladles and remelting superalloy scrap. The treatment of environmentally hazardous waste materials is a particularly interesting application because of the additional financial incentives. Non-transferred arc plasma generators will be used for air and gas preheating in blast furnaces to reduce metallurgical coke consumptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two sets of experiments, categorized as TG–FTIR and Py–GC–FTIR, are employed to investigate the mechanism of the hemicellulose pyrolysis and the formation of main gaseous and bio-oil products. The “sharp mass loss stage” and the corresponding evolution of the volatile products are examined by the TG–FTIR graphs at the heating rate of 3–80 K/min. A pyrolysis unit, composed of fluidized bed reactor, carbon filter, vapour condensing system and gas storage, is employed to investigate the products of the hemicellulose pyrolysis under different temperatures (400–690 °C) at the feeding flow rate of 600 l/h. The effects of temperature on the condensable products are examined thoroughly. The possible routes for the formation of the products are systematically proposed from the primary decomposition of the three types of unit (xylan, O-acetylxylan and 4-O-methylglucuronic acid) and the secondary reactions of the fragments. It is found that the formation of CO is enhanced with elevated temperature, while slight change is observed for the yield of CO2 which is the predominant products in the gaseous mixture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate if Magnetoencephalography (MEG) can add non-redundant information to guide implantation sites for intracranial recordings (IR). The contribution of MEG to intracranial recording planning was evaluated in 12 consecutive patients assessed pre-surgically with MEG followed by IR. Primary outcome measures were the identification of focal seizure onset in IR and favorable surgical outcome. Outcome measures were compared to those of 12 patients matched for implantation type in whom non-invasive pre-surgical assessment suggested clear hypotheses for implantation (non-MEG group). In the MEG group, non-invasive assessment without MEG was inconclusive, and MEG was then used to further help identify implantation sites. In all MEG patients, at least one virtual MEG electrode generated suitable hypotheses for the location of implantations. No differences in outcome measures were found between non-MEG and MEG groups. Although the MEG group included more complex patients, it showed similar percentage of successful implantations as the non-MEG group. This suggests that MEG can contribute to identify implantation sites where standard methods failed. © 2013 Springer Science+Business Media New York.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-surface-area silicon oximide-based gel [SiOC(H)=NSi]m[Si2N-C(H)=O]n[SiN(H)-C(H)=O]p[SiOC(H)=NH]q[SiNH]r[SiNH2]s[SiNMe2]t was prepared via a formamide-based aminolysis of tris(dimethylamino)silylamine, (Me2N)3SiNH2. The structure of the gel and the mechanism of formation are elucidated. Pyrolysis of the gel at 1000 °C under N2 flow gave an amorphous microporous oxynitride-based glass with a BET surface area of 195 m2 g−1. © The Royal Society of Chemistry 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Electrosurgery units are widely employed in modern surgery. Advances in technology have enhanced the safety of these devices, nevertheless, accidental burns are still regularly reported. This study focuses on possible causes of sacral burns as complication of the use of electrosurgery. Burns are caused by local densifications of the current, but the actual pathway of current within patient's body is unknown. Numerical electromagnetic analysis can help in understanding the issue. Methods: To this aim, an accurate heterogeneous model of human body (including seventy-seven different tissues), electrosurgery electrodes, operating table and mattress was build to resemble a typical surgery condition. The patient lays supine on the mattress with the active electrode placed onto the thorax and the return electrode on his back. Common operating frequencies of electrosurgery units were considered. Finite Difference Time Domain electromagnetic analysis was carried out to compute the spatial distribution of current density within the patient's body. A differential analysis by changing the electrical properties of the operating table from a conductor to an insulator was also performed. Results: Results revealed that distributed capacitive coupling between patient body and the conductive operating table offers an alternative path to the electrosurgery current. The patient's anatomy, the positioning and the different electromagnetic properties of tissues promote a densification of the current at the head and sacral region. In particular, high values of current density were located behind the sacral bone and beneath the skin. This did not occur in the case of non-conductive operating table. Conclusion: Results of the simulation highlight the role played from capacitive couplings between the return electrode and the conductive operating table. The concentration of current density may result in an undesired rise in temperature, originating burns in body region far from the electrodes. This outcome is concordant with the type of surgery-related sacral burns reported in literature. Such burns cannot be immediately detected after surgery, but appear later and can be confused with bedsores. In addition, the dosimetric analysis suggests that reducing the capacity coupling between the return electrode and the operating table can decrease or avoid this problem. © 2013 Bifulco et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate if magnetoencephalography (MEG) can identify implantation sites for intracranial recordings (IR). Method: Two groups of 12 patients assessed for surgery with IR with and without MEG were compared (MEG and control groups). In the control group, non-invasive presurgical assessment without MEG suggested clear hypotheses for implantation. In the MEG group, non-invasive assessment was inconclusive, and MEG was used to identify implantation sites. Both groups were matched for implantation type. The success of implantation was defined by findings in IR: a) Focal seizure onset; b)Unilateral focal abnormal responses to single pulse electrical stimulation(SPES); and c) Concordance between a) and b). Results: In all MEG patients, at least one virtual MEG electrode generated suitable hypotheses for the location of implantations. The proportion of patients showing focal seizure onset restricted to one hemisphere was similar in control and MEG groups (6/12 vs. 11/12, Fisher’s exact test,p = 0.0686). The proportion of patients showing unilateral responses to SPES was lower in the control than in the MEG group (7/12 vs. 12/12,p = 0.0373). Conclusion: The MEG group showed similar or higher incidence of successful implantations than controls.