10 resultados para PWM invertors

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hybrid passive-active damping solution with improved system stability margin and enhanced dynamic performance is proposed for high power grid interactive converters. In grid connected active rectifier/inverter application, line side LCL filter improves the high frequency attenuation and makes the converter compatible with the stringent grid power quality regulations. Passive damping though offers a simple and reliable solution but it reduces overall converter efficiency. Active damping solutions do not increase the system losses but can guarantee the stable operation up to a certain speed of dynamic response which is limited by the maximum bandwidth of the current controller. This paper examines this limit and introduces a concept of hybrid passive-active damping solution with improved stability margin and high dynamic performance for line side LCL filter based active rectifier/inverter applications. A detailed design, analysis of the hybrid approach and trade-off between system losses and dynamic performance in grid connected applications are reported. Simulation and experimental results from a 10 kVA prototype demonstrate the effectiveness of the proposed solution. An analytical study on system stability and dynamic response with the variations of various controller and passive filter parameters is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scope of this paper is to present the Pulse Width Modulation (PWM) based method for Active Power (AP) and Reactive Power (RP) measurements as can be applied in Power Meters. Necessarily, the main aim of the material presented is a twofold, first to present a realization methodology of the proposed algorithm, and second to verify the algorithm’s robustness and validity. The method takes advantage of the fact that frequencies present in a power line are of a specific fundamental frequency range (a range centred on the 50 Hz or 60 Hz) and that in case of the presence of harmonics the frequencies of those dominating in the power line spectrum can be specified on the basis of the fundamental. In contrast to a number of existing methods a time delay or shifting of the input signal is not required by the method presented and the time delay by n/2 of the Current signal with respect to the Voltage signal required by many of the existing measurement techniques, does not apply in the case of the PWM method as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Switched mode power supplies (SMPSs) are essential components in many applications, and electromagnetic interference is an important consideration in the SMPS design. Spread spectrum based PWM strategies have been used in SMPS designs to reduce the switching harmonics. This paper proposes a novel method to integrate a communication function into spread spectrum based PWM strategy without extra hardware costs. Direct sequence spread spectrum (DSSS) and phase shift keying (PSK) data modulation are employed to the PWM of the SMPS, so that it has reduced switching harmonics and the input and output power line voltage ripples contain data. A data demodulation algorithm has been developed for receivers, and code division multiple access (CDMA) concept is employed as communication method for a system with multiple SMPSs. The proposed method has been implemented in both Buck and Boost converters. The experimental results validated the proposed DSSS based PWM strategy for both harmonic reduction and communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two-way power flow is nothing new and has been in practical use using line commutated converters for at least 50 years. With these types of converters, reversal of power flow can be achieved by increasing the firing angle of the devices beyond 90 degrees thus producing a negative DC voltage. Line commutated converters have several known disadvantages including: the direct current cannot be reversed, the power factor decreases when the firing angle increases and the harmonics are high on the line current. To tackle the above problems a forced commutated converter can be used. The power factor can be unity and the harmonics can be reduced. Many researchers have used PWM with different control techniques to serve the above purposes. In each converter arm, they used a forced commutated device with an antiparallel diode. Under the rectification mode of operation the current path is preponderantly through the diodes and under the inverter operation the current flows preponderantly through the forced commutated devices. Although their results were encouraging and gave a unity power factor with nearly sinusoidal current, the main disadvantage was that there were difficulties in controlling the power factor when the system is needed to operate at lagging or leading power factor. In this work, a new idea was introduced by connecting two GTOs antiparallel instead of a diode and a GTO. A single phase system using two GTO converters which are connected in series was built. One converter operates as a rectifier and the other converter operates as an inverter. In the case of the inversion mode and in each inverter arm one GTO is operated as a diode simply by switching it always on and the other antiparallel GTO is operated as a normal device to carry the inverter current. In case of the rectification mode, in each arm one GTO is always off and the other GTP is operated as a controlled device. The main advantage is that the system can be operated at lagging or leading power factor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purified B-cells fail to proliferate in response to the strong thymus-independent (TI) antigen Lipopolysaccharide (LPS) in the absence of macrophages (Corbel and Melchers, 1983). The fact that macrophages, or factors derived from them are required is supported by the inability of marginal zone B-cells in infants to respond to highly virulent strains of bacteria such as Neisseria meningitidis and Streptococcus pneumoniae (Timens, 1989). This may be due to the lack of CD21 expression on B-cells in infants which could associate with its co-receptor (C3d) on adjacent macrophages. It is not clear whether cell surface contacts and/or soluble products are involved in lymphocyte-macrophage interactions in response to certain antigens. This thesis describes the importance of the macrophage in lymphocyte responses to T-dependent (TD) and TI antigens. The major findings of this thesis were as follows: (1). Macrophages were essential for a full proliferative response to a range of T - and B-cell mitogens and TI-1 and TI-2 antigens, including Concanavalin A, LPS, Pokeweed mitogen (PWM), Dextran sulphate, Phytohaemagglutinin-P (PHA-P) and Poly[I][C]. (2). A ratio of 1 macrophage to 1000 lymphocytes was sufficient for the mitogens to exert their effects. (3). The optimal conditions were established for the activation of an oxidative burst in cells of the monocyte/macrophage lineage as measured by luminometry. The order of ability was OpZ >PMA/lonomycin >f-MLP >Con A >DS >PHA >Poly[I][C] >LPS >PWM. Responses were only substantial and protracted with OpZ and PMA. Peritoneal macrophages were the most responsive cells, whereas splenic and alveolar macrophages were significantly less active and no response could be elicited with Kupffer cells, thus demonstrating heterogeneity between macrophages. (4). Activated macrophages that were then fixed with paraformaldehyde were unable to restore mitogenic responsiveness, even with a ratio of 1 macrophage to 5 lymphocytes. (5). Although highly purified T- and B-cells could respond to mitogen provided live macrophages were present, maximum activation was only observed when all 3 cell types were present. (6). Supernatants from purified macrophage cultures treated with a range of activators were able to partially restore lymphocyte responses to mitogen in macrophage-depleted splenocyte cultures, and purified T - and B-cell cultures. In fact supernatants from macrophages treated with LPS for only 30 minutes could restore responsiveness. Supernatants from OpZ treated macrophages were without effect. (7). Macrophage supernatants could not induce proliferation in the absence of mitogen. They therefore provide a co-mitogenic signal required by lymphocytes in order to respond to mitogen. (8). Macrophage product profiles revealed that LPS and Con A-treated macrophage supernatants showed elevated levels of IL-1β, TNF -α L TB4 and TXB2. These products were therefore good candidates as the co-mitogenic factor. The possible inhibitory factors secreted by OpZ-treated macrophages were PGE2, IL-10 and NO. (9). The removal of cytokines, eicosanoids and TNF-α from LPS-treated macrophage supernatants using Cycloheximide, Dexamethasone and an MMPI respectively, resulted in the inability of these supernatants to restore macrophage-depleted lymphocyte responses to mitogen. (10). rIL-1β and rTNF-α are co-mitogenic factors, as macrophage-depleted lymphocytes incubated with rIL-1β and rTNF-α can respond to mitogen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has concentrated on the testing of induction machines to determine their temperature rise at full-load without mechanically coupling to a load machine. The achievements of this work are outlined as follows. 1. Four distinct categories of mixed-frequency test using an inverter have been identified by the author. The simulation results of these tests as well as the conventional 2-supply test have been analysed in detail. 2. Experimental work on mixed-frequency tests has been done on a small (4 kW) squirrel cage induction machine using a voltage source PWM inverter. Two out of the four categories of test suggested have been tested and the temperature rise results were found to be similar to the results of a direct loading test. Further, one of the categories of test proposed has been performed on a 3.3 kW slip-ring induction machine for the conformation of the rotor values. 3. A low current supply mixed-frequency test-rig has been proposed. For this purpose, a resonant bank was connected to the DC link of the inverter in order to maintain the exchange of power between the test machine and the resonant bank instead of between the main supply and the test machine. The resonant bank was then replaced with a special electro-mechanical energy storage unit. The current of the main power supply was then reduced in amplitude. 4. A variable inertia test for full load temperature rise testing of induction machines has been introduced. This test is purely mechanical in nature and does not require any electrical connection of the test machine to any other machine. It has the advantage of drawing very little net power from the supply.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

VSC converters are becoming more prevalent for HVDC applications. Two circuits are commercially available at present, a traditional six-switch, PWM inverter, implemented using series connected IGBTs - ABBs HVDC Light®, and the other a modular multi-level converter (MMC) - Siemens HVDC-PLUS. This paper presents an alternative MMC topology, which utilises a novel current injection technique, and exhibits several desirable characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the development of communication systems such as Internet of Things, integrating communication with power supplies is an attractive solution to reduce supply cost. This paper presents a novel method of power/signal dual modulation (PSDM), by which signal transmission is integrated with power conversion. This method takes advantage of the intrinsic ripple initiated in switch mode power supplies as signal carriers, by which cost-effective communications can be realized. The principles of PSDM are discussed, and two basic dual modulation methods (specifically PWM/FSK and PWM/PSK) are concluded. The key points of designing a PWM/FSK system, including topology selection, carrier shape, and carrier frequency, are discussed to provide theoretical guidelines. A practical signal modulation-demodulation method is given, and a prototype system provides experimental results to verify the effectiveness of the proposed solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

System efficiency and cost effectiveness are of critical importance for photovoltaic (PV) systems. This paper addresses the two issues by developing a novel three-port dc-dc converter for stand-alone PV systems, based on an improved Flyback-Forward topology. It provides a compact single-unit solution with a combined feature of optimized maximum power point tracking (MPPT), high step-up ratio, galvanic isolation, and multiple operating modes for domestic and aerospace applications. A theoretical analysis is conducted to analyze the operating modes followed by simulation and experimental work. This paper is focused on a comprehensive modulation strategy utilizing both PWM and phase-shifted control that satisfies the requirement of PV power systems to achieve MPPT and output voltage regulation. A 250-W converter was designed and prototyped to provide experimental verification in term of system integration and high conversion efficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A DSP implementation of Space Vector PWM (SVPWM) using constant V/Hz control for the open winding doubly-fed generator is proposed. This control of SVPWM modulation mode and open winding structure combination has the high voltage utilization ratio, greatly improves the control precision of the system, and reduces the stator winding output current distortion rate, though the complexity of the system is increased. This paper describes the basic principle of SVPWM and discusses the particularity of SVPWM waveform generated by hybrid vector under the condition of open winding. This method is applied to a state of doubly-fed wind power generator. The experimental verification shows that this control method can make the output voltage amplitude of the doubly-fed induction generator be 380V and the frequency be 50Hz by using of TMS32028335 chip based on constant V/Hz control of symmetric SVPWM modulation wave.