14 resultados para POST-OPERATIVE COMPLICATIONS

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Changes in the design of hospital wards have usually been determined by architects and members of the nursing and medical professions; the views and preferences of patients have seldom been sought directly. The Hospital Anxiety and Depression scale and the Disturbance Due to Hospital Noise questionnaire were administered to 64 female patients on bay and Nightingale wards together with a questionnaire designed for this study. Perceptions of social and physical factors of ward design were examined, and their relationship to psychological well-being and sleep patterns. The results show that the bay ward seemed to offer a more favourable environment for patients but some of the disadvantages of bay wards are balanced by better staffing levels and better and more modern facilities. Visibility to nurses was lower on the bay ward. The Nightingale ward was perceived as significantly noisier than the bay ward and noise levels were significantly correlated to anxiety scores. Paradoxically the increase in noise levels appeared to improve the perceived level of privacy on the Nightingale ward. Seventy-five per cent of patients were found to prefer the bay ward design, and since neither design appears to have major disadvantages their continued introduction should be encouraged. However, recommendations are made concerning the optimizing of patients' well-being within the bay ward setting.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the last decade we have seen an exponential growth of functional imaging studies investigating multiple aspects of language processing. These studies have sparked an interest in applying some of the paradigms to various clinically relevant questions, such as the identification of the cortical regions mediating language function in surgical candidates for refractory epilepsy. Here we present data from a group of adult control participants in order to investigate the potential of using frequency specific spectral power changes in MEG activation patterns to establish lateralisation of language function using expressive language tasks. In addition, we report on a paediatric patient whose language function was assessed before and after a left hemisphere amygdalo-hippocampectomy. Our verb generation task produced left hemisphere decreases in beta-band power accompanied by right hemisphere increases in low beta-band power in the majority of the control group, a previously unreported phenomenon. This pattern of spectral power was also found in the patient's post-surgery data, though not her pre-surgery data. Comparison of pre and post-operative results also provided some evidence of reorganisation in language related cortex both inter- and intra-hemispherically following surgery. The differences were not limited to changes in localisation of language specific cortex but also changes in the spectral and temporal profile of frontal brain regions during verb generation. While further investigation is required to establish concordance with invasive measures, our data suggest that the methods described may serve as a reliable lateralisation marker for clinical assessment. Furthermore, our findings highlight the potential utility of MEG for the investigation of cortical language functioning in both healthy development and pathology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High levels of corneal astigmatism are prevalent in a significant proportion of the population. During cataract surgery pre-existing astigmatism can be corrected using single or paired incisions on the steep axis of the cornea, using relaxing incisions or with the use of a toric intraocular lens. This review provides an overview of the conventional methods of astigmatic correction during cataract surgery and in particular, discusses the various types of toric lenses presently available and the techniques used in determining the correct axis for the placement of such lenses. Furthermore, the potential causes of rotation in toric lenses are identified, along with techniques for assessing and quantifying the amount of rotation and subsequent management options for addressing post-operative rotation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate theoretically three previously published formulae that use intra-operative aphakic refractive error to calculate intraocular lens (IOL) power, not necessitating pre-operative biometry. The formulae are as follows: IOL power (D) = Aphakic refraction x 2.01 [Ianchulev et al., J. Cataract Refract. Surg.31 (2005) 1530]; IOL power (D) = Aphakic refraction x 1.75 [Mackool et al., J. Cataract Refract. Surg.32 (2006) 435]; IOL power (D) = 0.07x(2) + 1.27x + 1.22, where x = aphakic refraction [Leccisotti, Graefes Arch. Clin. Exp. Ophthalmol.246 (2008) 729]. METHODS: Gaussian first order calculations were used to determine the relationship between intra-operative aphakic refractive error and the IOL power required for emmetropia in a series of schematic eyes incorporating varying corneal powers, pre-operative crystalline lens powers, axial lengths and post-operative IOL positions. The three previously published formulae, based on empirical data, were then compared in terms of IOL power errors that arose in the same schematic eye variants. RESULTS: An inverse relationship exists between theoretical ratio and axial length. Corneal power and initial lens power have little effect on calculated ratios, whilst final IOL position has a significant impact. None of the three empirically derived formulae are universally accurate but each is able to predict IOL power precisely in certain theoretical scenarios. The formulae derived by Ianchulev et al. and Leccisotti are most accurate for posterior IOL positions, whereas the Mackool et al. formula is most reliable when the IOL is located more anteriorly. CONCLUSION: Final IOL position was found to be the chief determinant of IOL power errors. Although the A-constants of IOLs are known and may be accurate, a variety of factors can still influence the final IOL position and lead to undesirable refractive errors. Optimum results using these novel formulae would be achieved in myopic eyes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Post-operative infections resulting from total hip arthroplasty are caused by bacteria such as Staphylococcus aureus and Pseudomonas aeruginosa entering the wound perioperatively or by haemetogenous spread from distant loci of infection. They can endanger patient health and require expensive surgical revision procedures. Gentamicin impregnated poly (methyl methacrylate) bone cement is traditionally used for treatment but is often removed due to harbouring bacterial growth, while bacterial resistance to gentamicin is increasing. The aim of this work was to encapsulate the antibiotics vancomycin, ciprofloxacin and rifampicin within sustained release microspheres composed of the biodegradable polymer poly (dl-lactide-co-glycolide) [PLCG] 75:25. Topical administration to the wound in hydroxypropylmethylcellulose gel should achieve high local antibiotic concentrations while the two week in vivo half life of PLCG 75:25 removes the need for expensive surgical retrieval operations. Unloaded and 20% w/w antibiotic loaded PLCG 75:25 microspheres were fabricated using a Water in Oil emulsification with solvent evaporation technique. Microspheres were spherical in shape with a honeycomb-like internal matrix and showed reproducible physical properties. The kinetics of in vitro antibiotic release into newborn calf serum (NCS) and Hank's balanced salt solution (HBSS) at 37°C were measured using a radial diffusion assay. Generally, the day to day concentration of each antibiotic released into NCS over a 30 day period was in excess of that required to kill St. aureus and Ps. auruginosa. Only limited microsphere biodegradation had occurred after 30 days of in vitro incubation in NCS and HBSS at 37°C. The moderate in vitro cytotoxicity of 20% w/w antibiotic loaded microspheres to cultured 3T3-L1 cells was antibiotic induced. In conclusion, generated data indicate the potential for 20% w/w antibiotic loaded microspheres to improve the present treatment regimens for infections occurring after total hip arthroplasty such that future work should focus on gaining industrial collaboration for commercial exploitation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study evaluated sources of within- and between-subject variability in standard white-on-white (W-W) perimetry and short-wavelength automated perimetry (SWAP). The Influence of staircase strategy on the fatigue effect in W-W perimetry was investigated for a 4 dB single step, single reversal strategy; a variable step size, single reversal dynamic strategy; and the standard 4-2 dB double reversal strategy. The fatigue effect increased as the duration of the examination Increased and was greatest in the second eye for all strategies. The fatigue effect was lowest for the 4dB strategy, which exhibited the shortest examination time and was greatest for the 4-2 dB strategy, which exhibited the longest examination time. Staircase efficiency was lowest for the 4 dB strategy and highest for the dynamic strategy which thus offers a reduced examination time and low inter-subject variability. The normal between-subject variability of SWAP was determined for the standard 4-2 dB double reversal strategy and the 3 dB single reversal FASTPAC strategy and compared to that of W-W perimetry, The decrease in sensitivity with Increase in age was greatest for SWAP. The between-subject variability of SWAP was greater than W-W perimetry. Correction for the Influence of ocular media absorption reduced the between-subject variability of SWAP, The FASTPAC strategy yielded the lowest between-subject variability In SWAP, but the greatest between-subject variability In WoW perimetry. The greater between-subject variability of SWAP has profound Implications for the delineation of visual field abnormality, The fatigue effect for the Full Threshold strategy in SWAP was evaluated with conventional opaque, and translucent occlusion of the fellow eye. SWAP exhibited a greater fatigue effect than W-W perimetry. Translucent occlusion reduced the between-subject variability of W-W perimetry but Increased the between-subject variability of SWAP. The elevation of sensitivity was greater with translucent occlusion which has implications for the statistical analysis of W-W perimetry and SWAP. The influence of age-related cataract extraction and IOL implantation upon the visual field derived by WoW perimetry and SWAP was determined. Cataract yielded a general reduction In sensitivity which was preferentially greater in SWAP, even after the correction of SWAP for the attenuation of the stimulus by the ocular media. There was no correlation between either backward or forward light scatter and the magnitude of the attenuation of W-W or SWAP sensitivity. The post-operative mean deviation in SWAP was positive and has ramifications for the statistical Interpretation of SWAP. Short-wavelength-sensitive pathway isolation was assessed as a function of stimulus eccentricity using the two-colour Increment threshold method. At least 15 dB of SWS pathway Isolation was achieved for 440 nm, 450 nm and 460 nm stimuli at a background luminance of 100 cdm-2, There was a slight decrease In SWS pathway Isolation for all stimulus wavelengths with increasing eccentricity which was not of clinical significance. Adopting a 450 nm stimulus may reduce between-subject variability In SWAP due to a reduction In ocular media absorption and macular pigment absorption.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes an innovative sensing approach allowing capture, discrimination, and classification of transients automatically in gait. A walking platform is described, which offers an alternative design to that of standard force plates with advantages that include mechanical simplicity and less restriction on dimensions. The scope of the work is to investigate as an experiment the sensitivity of the distributive tactile sensing method with the potential to address flexibility on gait assessment, including patient targeting and the extension to a variety of ambulatory applications. Using infrared sensors to measure plate deflection, gait patterns are compared with stored templates using a pattern recognition algorithm. This information is input into a neural network to classify normal and affected walking events, with a classification accuracy of just under 90 per cent achieved. The system developed has potential applications in gait analysis and rehabilitation, whereby it can be used as a tool for early diagnosis of walking disorders or to determine changes between pre- and post-operative gait.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Provision of information and behavioural instruction has been demonstrated to improve recovery after surgery. However, patients draw on a range of information sources and it is important to establish which sources patients use and how this influences perceptions and behaviour as they progress along the surgical pathway. In this qualitative, exploratory and longitudinal study, the use of information and instruction were explored from the perspective of people undergoing inguinal hernia repair surgery. Seven participants undergoing inguinal hernia repair surgery were interviewed using semi-structured interviews 2 weeks before surgery and 2 weeks and 4 months post-surgery. Nineteen interviews were conducted in total. Topic guides included sources of knowledge, reasons for help-seeking and opting for surgery and factors influencing return to activity. Data were analysed thematically according to Interpretative Phenomenological Analysis. Participants sought information from a range of sources, focusing on informal information sources before surgery and using information and instruction from health-care professionals post-surgery. This information influenced behaviours including deciding to undergo surgery, use of pain medication and returning to usual activity. Anxiety and help-seeking resulted when unexpected post-surgical events occurred such as extensive bruising. Findings were consistent with psychological and sociological theories. Overall, participants were positive about the information and instruction they received but expressed a desire for more timely information on post-operative adverse events.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The automated sensing scheme described in this paper has the potential to automatically capture, discriminate and classify transients in gait. The mechanical simplicity of the walking platform offers advantages over standard force plates. There is less restriction on dimensions offering the opportunity for multi-contact and multiple steps. This addresses the challenge of patient targeting and the evaluation of patients in a variety of ambulatory applications. In this work the sensitivity of the distributive tactile sensing method has been investigated experimentally. Using coupled time series data from a small number of sensors, gait patterns are compared with stored templates using a pattern recognition algorithm. By using a neural network these patterns were interpreted classifying normal and affected walking events with an accuracy of just under 90%. This system has potential in gait analysis and rehabilitation as a tool for early diagnosis in walking disorders, for determining response to therapy and for identifying changes between pre and post operative gait. Copyright © 2009 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A significant proportion of patients experience chronic post-surgical pain (CPSP) following inguinal hernia surgery. Psychological models are useful in predicting acute pain after surgery, and in predicting the transition from acute to chronic pain in non-surgical contexts. This is a prospective cohort study to investigate psychological (cognitive and emotional) risk factors for CPSP after inguinal hernia surgery. Participants were asked to complete questionnaires before surgery and 1 week and 4 months after surgery. Data collected before surgery and 1 week after surgery were used to predict pain at 4 months. Psychological risk factors assessed included anxiety, depression, fear-avoidance, activity avoidance, catastrophizing, worry about the operation, activity expectations, perceived pain control and optimism. The study included 135 participants; follow-up questionnaires were returned by 119 (88.1%) and 115 (85.2%) participants at 1 week and 4 months after surgery respectively. The incidence of CPSP (pain at 4 months) was 39.5%. After controlling for age, body mass index and surgical variables (e.g. anaesthetic, type of surgery and mesh type used), lower pre-operative optimism was an independent risk factor for CPSP at 4 months; lower pre-operative optimism and lower perceived control over pain at 1 week after surgery predicted higher pain intensity at 4 months. No emotional variables were independently predictive of CPSP. Further research should target these cognitive variables in pre-operative psychological preparation for surgery. © 2011 European Federation of International Association for the Study of Pain Chapters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lifelong surveillance is not cost-effective after endovascular aneurysm repair (EVAR), but is required to detect aortic complications which are fatal if untreated (type 1/3 endoleak, sac expansion, device migration). Aneurysm morphology determines the probability of aortic complications and therefore the need for surveillance, but existing analyses have proven incapable of identifying patients at sufficiently low risk to justify abandoning surveillance. This study aimed to improve the prediction of aortic complications, through the application of machine-learning techniques. Patients undergoing EVAR at 2 centres were studied from 2004–2010. Aneurysm morphology had previously been studied to derive the SGVI Score for predicting aortic complications. Bayesian Neural Networks were designed using the same data, to dichotomise patients into groups at low- or high-risk of aortic complications. Network training was performed only on patients treated at centre 1. External validation was performed by assessing network performance independently of network training, on patients treated at centre 2. Discrimination was assessed by Kaplan-Meier analysis to compare aortic complications in predicted low-risk versus predicted high-risk patients. 761 patients aged 75 +/− 7 years underwent EVAR in 2 centres. Mean follow-up was 36+/− 20 months. Neural networks were created incorporating neck angu- lation/length/diameter/volume; AAA diameter/area/volume/length/tortuosity; and common iliac tortuosity/diameter. A 19-feature network predicted aor- tic complications with excellent discrimination and external validation (5-year freedom from aortic complications in predicted low-risk vs predicted high-risk patients: 97.9% vs. 63%; p < 0.0001). A Bayesian Neural-Network algorithm can identify patients in whom it may be safe to abandon surveillance after EVAR. This proposal requires prospective study.