13 resultados para PLATFORM VESSEL

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac function, such as heart rate variability, is abnormal in coronary artery disease, but its relation with the function of ocular and nail-fold blood vessels is unknown. The hypothesis was that there is abnormal retinal and peripheral microvascular endothelial function compared with large blood vessel and cardiac function. Twenty-four patients with coronary artery disease (CAD) and 30 healthy, age- and sex-matched control subjects were enrolled in the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel biosensing system based on a micromachined rectangular silicon membrane is proposed and investigated in this paper. A distributive sensing scheme is designed to monitor the dynamics of the sensing structure. An artificial neural network is used to process the measured data and to identify cell presence and density. Without specifying any particular bio-application, the investigation is mainly concentrated on the performance testing of this kind of biosensor as a general biosensing platform. The biosensing experiments on the microfabricated membranes involve seeding different cell densities onto the sensing surface of membrane, and measuring the corresponding dynamics information of each tested silicon membrane in the form of a series of frequency response functions (FRFs). All of those experiments are carried out in cell culture medium to simulate a practical working environment. The EA.hy 926 endothelial cell lines are chosen in this paper for the bio-experiments. The EA.hy 926 endothelial cell lines represent a particular class of biological particles that have irregular shapes, non-uniform density and uncertain growth behaviour, which are difficult to monitor using the traditional biosensors. The final predicted results reveal that the methodology of a neural-network based algorithm to perform the feature identification of cells from distributive sensory measurement has great potential in biosensing applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. METHODS. SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. RESULTS. Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P 0.05). As a validation of that finding, SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P 0.243). However, SDRA revealed that smokers’ vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P 0.005) and an increased stiffness of retinal arterioles (P 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. CONCLUSIONS. SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis documents the design, implementation and testing of a smart sensing platform that is able to discriminate between differences or small changes in a persons walking. The distributive tactile sensing method is used to monitor the deflection of the platform surface using just a small number of sensors and, through the use of neural networks, infer the characteristics of the object in contact with the surface. The thesis first describes the development of a mathematical model which uses a novel method to track the position of a moving load as it passes over the smart sensing surface. Experimental methods are then described for using the platform to track the position of swinging pendulum in three dimensions. It is demonstrated that the method can be extended to that of real-time measurement of balance and sway of a person during quiet standing. Current classification methods are then investigated for use in the classification of different gait patterns, in particular to identify individuals by their unique gait pattern. Based on these observations, a novel algorithm is developed that is able to discriminate between abnormal and affected gait. This algorithm, using the distributive tactile sensing method, was found to have greater accuracy than other methods investigated and was designed to be able to cope with any type of gait variation. The system developed in this thesis has applications in the area of medical diagnostics, either as an initial screening tool for detecting walking disorders or to be able to automatically detect changes in gait over time. The system could also be used as a discrete biometric identification method, for example identifying office workers as they pass over the surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an innovative sensing approach allowing capture, discrimination, and classification of transients automatically in gait. A walking platform is described, which offers an alternative design to that of standard force plates with advantages that include mechanical simplicity and less restriction on dimensions. The scope of the work is to investigate as an experiment the sensitivity of the distributive tactile sensing method with the potential to address flexibility on gait assessment, including patient targeting and the extension to a variety of ambulatory applications. Using infrared sensors to measure plate deflection, gait patterns are compared with stored templates using a pattern recognition algorithm. This information is input into a neural network to classify normal and affected walking events, with a classification accuracy of just under 90 per cent achieved. The system developed has potential applications in gait analysis and rehabilitation, whereby it can be used as a tool for early diagnosis of walking disorders or to determine changes between pre- and post-operative gait.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural retinal vascular characteristics, such as vessel calibers, tortuosity and bifurcation angles are increasingly quantified in an objective manner, slowly replacing subjective qualitative disease classification schemes. This paper provides an overview of the current methodologies and calculations used to compute retinal vessel tortuosity. We set out the different parameter calculations and provide an insight into the clinical applications, while critically reviewing its pitfalls and shortcomings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pregnancy is characterized by an inflammatory-like process and this may be exacerbated in preeclampsia. The heme oxygenase (HO) enzymes generate carbon monoxide (CO) that induces blood vessel relaxation and biliverdin that acts as an endogenous antioxidant. Materials and Methods: We examined the expression and localization of HO-1 and HO-2 in normal and preeclamptic placenta using reverse transcription polymerase chain reaction (RT-PCR), RNase protection assay, immunoblotting and immunohistochemistry. In addition, the effect of HO activation on tumor necrosis factor-alpha (TNF) induced placental damage and on feto-placental circulation was studied. Results: We provide the first evidence for the role of HO as an endogenous placental factor involved with cytoprotection and placental blood vessel relaxation. HO-1 was significantly higher at term, compared with first trimester placentae indicating its role in placental vascular development and regulation. HO-1 predominantly localized in the extravascular connective tissue that forms the perivascular contractile sheath around the developing blood vessels. HO-2 was localized in the capillaries, as well as the villous stroma, with weak staining of trophoblast. Induction of HO-1 caused a significant attenuation of TNF-mediated cellular damage in placental villous explants, as assessed by lactate dehydrogenase leakage (p 0.01). HO-1 protein was significantly reduced in placentae from pregnancies complicated with preeclampsia, compared with gestationally matched normal pregnancies. This suggests that the impairment of HO-1 activation may compromise the compensatory mechanism and predispose the placenta to cellular injury and subsequent maternal endothelial cell activation. Isometric contractility studies showed that hemin reduced vascular tension by 61% in U46619-preconstricted placental arteries. Hemininduced vessel relaxation and CO production was inhibited by HO inhibitor, tin protoporphyrin IX. Conclusions: Our findings establish HO-1 as an endogenous system that offers protection against cytotoxic damage in the placenta, identifies the HO-CO pathway to regulate feto-placental circulation and provides a new approach to study the disease of preeclampsia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this research is to consider the possible effect of an emerging technology platform on the uptake of online shopping: interactive (digital) Television (iTV), which enables viewers to select a variety of viewing options, publicity materials, games, entertainment and more recently shopping. An augmented version of the original TAM is applied to this study. Two new constructs are considered namely access and awareness together with perceived ease of use, perceived usefulness, perceived enjoyment and security. The results show that indeed the augmented TAM can be used as a predictive model for the adoption of iTV as an online shopping platform. It is concluded that access, perceived ease of use, perceived enjoyment and perceived usefulness are significant factors to determine the consumers’behavioural intentions towards the use of digital TV as a new shopping platform. However, awareness and security are considered to be insignificant with no effect on consumers’ behavioural intentions towards the new shopping medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Retinal Vessel Analyser (RVA) is a commercially available ophthalmoscopic instrument capable of acquiring vessel diameter fluctuations in real time and in high temporal resolution. Visual stimulation by means of flickering light is a unique exploration tool of neurovascular coupling in the human retina. Vessel reactivity as mediated by local vascular endothelial vasodilators and vasoconstrictors can be assessed non-invasively, in vivo. In brief, the work in this thesis • deals with interobserver and intraobserver reproducibility of the flicker responses in healthy volunteers • explains the superiority of individually analysed reactivity parameters over vendorgenerated output • links in static retinal measures with dynamic ones • highlights practical limitations in the use of the RVA that may undermine its clinical usefulness • provides recommendations for standardising measurements in terms of vessel location and vessel segment length and • presents three case reports of essential hypertensives in a -year follow-up. Strict standardisation of measurement procedures is a necessity when utilising the RVA system. Agreement between research groups on implemented protocols needs to be met, before it could be considered a clinically useful tool in detecting or predicting microvascular dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discussed the specific challenges of the agri-food sector in the light of research carried out in the Smart-AgriFod project. Using questionnaires and focus groups, our research identified as number of business needs and drivers which enable the identification of suitable Future Internet technologies across the three sub-domains of Smart Farming, Smart Agri-logistics, and Smart Food Awareness. The universal need for information access and the importance of standards to enable this lead us to propose an integrated scenario for end to end information access from farm to fork. We conclude by discussing wider implications of such developments especially for climate change and urbanisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the impact of light scatter, similar to that introduced by cataract on retinal vessel blood oxygen saturation measurements using poly-bead solutions of varying concentrations. Eight healthy, young, non-smoking individuals were enrolled for this study. All subjects underwent digital blood pressure measurements, assessment of non-contact intraocular pressure, pupil dilation and retinal vessel oximetry using dual wavelength photography (Oximetry Module, Imedos Systems, Germany). To simulate light scatter, cells comprising a plastic collar and two plano lenses were filled with solutions of differing concentrations (0.001, 0.002 and 0.004%) of polystyrene microspheres (Polysciences Inc., USA). The adopted light scatter model showed an artifactual increase in venous optical density ratio (p=0.036), with the 0.004% condition producing significantly higher venous optical density ratio values when compared to images without a cell in place. Spectrophotometric analysis, and thus retinal vessel oximetry of the retinal vessels, is altered by artificial light scatter. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Worldwide concern over dwindling fossil fuel reserves and impact of CO2 emissions on climate change means there is an urgent need to reduce our dependence on oil based sources of fuels and chemicals. The direct conversion of lignocellulosic derived glucose to 5-Hydroxymethylfurfural (5-HMF) is an attractive process for the production of chemicals and fuels but requires a bi-functional catalyst with acid-base or Lewis-Brönsted sites which can operate efficiently in the aqueous phase. While conventionally viewed as a superacid, the potential for tuning the acid strength in SO4/ZrO2 and potential for coupling bi-functional ZrO2-SO4/ZrO2 sites at low sulfate contents have been overlooked. Our previous work has shown effective tuning of the acid strength in SO4/ZrO2 can be used to direct selectivity in terpene isomerisation thus we rationalised control over HMF selectivity could achieved in a similar fashion. Here we report on a systematic study of the impact of acid properties of SO4/ZrO2 catalysts on the conversion of C6 sugars to 5-HMF in aqueous media and correlate the surface acid-base properties with glucose isomerisation and dehydration capabilities.