24 resultados para Other Analytical, Diagnostic and Therapeutic Techniques and Equipment
em Aston University Research Archive
Resumo:
Future optical networks will require the implementation of very high capacity (and therefore spectral efficient) technologies. Multi-carrier systems, such as Orthogonal Frequency Division Multiplexing (OFDM) and Coherent WDM (CoWDM), are promising candidates. In this paper, we present analytical, numerical, and experimental investigations of the impact of the relative phases between optical subcarriers of CoWDM systems, as well as the effect that the number of independently modulated subcarriers can have on the performance. We numerically demonstrate a five-subcarrier and three-subcarrier 10-GBd CoWDM system with direct detected amplitude shift keying (ASK) and differentially/coherently detected (D) phase shift keying (PSK). The simulation results are compared with experimental measurements of a 32-Gbit/s DPSK CoWDM system in two configurations. The first configuration was a practical 3-modulator array where all three subcarriers were independently modulated, the second configuration being a traditional 2-modulator odd/even configuration, where only odd and even subcarriers were independently modulated. Simulation and experimental results both indicate that the independent modulation implementation has a greater dependency on the relative phases between subcarriers, with a stronger penalty for the center subcarrier than the odd/even modulation scheme.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Thermal effects in uncontrolled factory environments are often the largest source of uncertainty in large volume dimensional metrology. As the standard temperature for metrology of 20°C cannot be achieved practically or economically in many manufacturing facilities, the characterisation and modelling of temperature offers a solution for improving the uncertainty of dimensional measurement and quantifying thermal variability in large assemblies. Technologies that currently exist for temperature measurement in the range of 0-50°C have been presented alongside discussion of these temperature measurement technologies' usefulness for monitoring temperatures in a manufacturing context. Particular aspects of production where the technology could play a role are highlighted as well as practical considerations for deployment. Contact sensors such as platinum resistance thermometers can produce accuracy closest to the desired accuracy given the most challenging measurement conditions calculated to be ∼0.02°C. Non-contact solutions would be most practical in the light controlled factory (LCF) and semi-invasive appear least useful but all technologies can play some role during the initial development of thermal variability models.
Resumo:
Manufacturers are seeking increasingly innovative ways to achieve competitive advantage. An emerging trend is to exploit diagnostic and prognostic technology to support service-led competitive strategies where the emphasis is put on the 'sale of use' rather than the 'sale of product'. However, little is known about the extent to which this technology is being exploited, the drivers and inhibitors, and the sectors where adoption is most prolific. This paper introduces the results of a survey conducted across the UK manufacturing sector to explore the extent, motivations, benefits, and challenges of deploying diagnostic and prognostic technology as an element of competitive strategy.
Resumo:
BACKGROUND: "One-stop" outpatient hysteroscopy clinics have become well established for the investigation and treatment of women with abnormal uterine bleeding. However, the advantages of these clinics may be offset by patient factors such as anxiety, pain, and dissatisfaction. This study aimed to establish patients' views and experiences of outpatient service delivery in the context of a one-stop diagnostic and therapeutic hysteroscopy clinic, to determine the amount of anxiety experienced by these women and compare this with other settings, and to determine any predictors for patient preferences. METHODS: The 20-item State-Trait Anxiety Inventory was given to 240 women attending a one-stop hysteroscopy clinic: to 73 consecutive women before their appointment in a general gynecology clinic and to 36 consecutive women attending a chronic pelvic pain clinic. The results were compared with published data for the normal female population, for women awaiting major surgery, and for women awaiting a colposcopy clinic appointment. In addition, a questionnaire designed to ascertain patients' views and experiences was used. Logistic regression analysis was used to delineate the predictive values of diagnostic or therapeutic hysteroscopy, and to determine their effect on the preference of patients to have the procedure performed under general anesthesia in the future. RESULTS: Women attending the hysteroscopy clinic in this study reported significantly higher levels of anxiety than those attending the general gynecology clinic (median, 45 vs 39; p = 0.004), but the levels of anxiety were comparable with those of women attending the chronic pelvic pain clinic (median, 45 vs 46; p = 0.8). As compared with the data from the normal female population (mean, 35.7) and those reported for women awaiting major surgery (mean, 41.2), the levels of anxiety experienced before outpatient hysteroscopy clinic treatment were found to be higher (mean, 45.7). Only women awaiting colposcopy (6-item mean score, 51.1 +/- 13.3) experienced significantly higher anxiety scores than the women awaiting outpatient hysteroscopy (6-item mean score, 47.3 +/- 13.9; p = 0.002). Despite their anxiety, most women are satisfied with the outpatient hysteroscopy "see and treat" service. High levels of anxiety, particularly concerning pain but not operative intervention, were significant predictors of patients desiring a future procedure to be performed under general anesthesia. CONCLUSIONS: Outpatient hysteroscopy is associated with significant anxiety, which increases the likelihood of intolerance for the outpatient procedure. However, among those undergoing operative therapeutic procedures, dissatisfaction was not associated with the outpatient setting.
Resumo:
The work presents a new method that combines plasma etching with extrinsic techniques to simultaneously measure matrix and surface protein and lipid deposits. The acronym for this technique is PEEMS - Plasma Etching and Emission Monitoring System. Previous work has identified the presence of proteinaceous and lipoidal deposition on the surface of contact lenses and highlighted the probability that penetration of these spoilants will occur. This technique developed here allows unambiguous identification of the depth of penetration of spoilants to be made for various material types. It is for this reason that the technique has been employed in this thesis. The technique is applied as a 'molecular' scalpel, removing known amounts of material from the target. In this case from both the anterior .and posterior surfaces of a 'soft' contact lens. The residual material is then characterised by other analytical techniques such as UV/visible .and fluorescence spectroscopy. Several studies have be.en carried out for both in vivo and in vitro spoilt materials. The analysis and identification of absorbed protein and lipid of the substrate revealed the importance of many factors in the absorption and adsorption process. The effect of the material structure, protein nature (in terms of size, shape and charge) and environment conditions were examined in order to determine the relative uptake of tear proteins. The studies were extended to real cases in order to study the. patient dependent factors and lipoidal penetration.
Resumo:
The project objective was to develop a reliable selection procedure to match contact lens materials with individual wearers by the identification of a biochemical marker for assessment of in-eye performance of contact lenses. There is a need for such a procedure as one of the main reasons for contact lens wearers ceasing wearing contact lenses is poor end of day comfort i.e. the lenses become intolerable to the wearer as the day progresses. The selection of an optimal material for individual wearers has the potential benefit to reduce drop Qut, hence increasing the overall contact lens population, and to improve contact lens comfort for established wearers. Using novel analytical methods and statistical techniques, we were able to investigate the interactions between the composition of the tear film and of the biofilm deposited on the contact lenses and contact lens performance. The investigations were limited to studying the lipid components of the tear film; the lipid layer, which plays a key role in preventing evaporation and stabilising the tear film, has been reported to be significantly thinner and of different mixing characteristics during contact lens wear. Different lipid families were found to influence symptomatology, in vivo tear film structure and stability as well as ocular integrity. Whereas the symptomatology was affected by both the tear film lipid composition and the nature of the lipid deposition, the structure of the tear film and its stability were mainly influenced by the tear film lipid composition. The ocular integrity also appeared to be influenced by the nature of the lipid deposition. Potential markers within the lipid species have been identified and could be applied as follows: When required in order to identify a problematic wearer or to match the contact lens material to the contact lens wearer, tear samples collected by the clinician could be dispatched to an analytical laboratory where lipid analysis could be carried out by HPLC. A colorimetric kit based on the lipid markers could also be developed and used by clinician directly in the practice; such a kit would involve tear sampling and classification according to the colour into "Problem", "Border line" and "Good" contact lens wearers groups. A test kit would also have wider scope for marketing in other areas such as general dry-eye pathology.
Resumo:
Recent research has investigated the capability of the Diagnostic and Statistical Manual for Mental Disorders (DSM-5) descriptions to identify individuals who should receive a diagnosis of Autism Spectrum Disorder (ASD) using standardised diagnostic instruments. Building on previous research investigating behaviours essential for the diagnosis of DSM-5 ASD, the current study investigated the sensitivity and specificity of a set of 14 items derived from the Diagnostic Interview for Social and Communication Disorders (DISCO Signposting set) that have potential for signposting the diagnosis of autism according to both the new DSM-5 criteria for ASD and ICD-10 criteria for Childhood Autism. An algorithm threshold for the Signposting set was calculated in Sample 1 (n = 67), tested in an independent validation sample (Sample 2; n = 78), and applied across age and ability sub-groups in Sample 3 (n = 190). The algorithm had excellent predictive validity according to best estimate clinical diagnosis (Samples 1 and 2) and excellent agreement with established algorithms for both DSM-5 and ICD-10 (all samples). The signposting set has potential to inform our understanding of the profile of ASD in relation to other neurodevelopmental disorders and to form the basis of a Signposting Interview for use in clinical practice.
Resumo:
1. Standard and high-performance anion-exchange-chromatographic techniques have been used to purify myo-[3H]inositol pentakisphosphates from various myo-[3H]inositol-prelabelled cells. Slime mould (Dictyostelium discoideum) contained 8 microM-myo-[3H]inositol 1,3,4,5,6-pentakisphosphate 16 microM-myo-[3H]inositol 1,2,3,4,6-pentakisphosphate and 36 microM-D-myo-[3H]inositol 1,2,4,5,6-pentakisphosphate [calculated intracellular concentrations; Stephens & Irvine (1990) Nature (London) 346 580-583]; germinating mung-bean (Phaseolus aureus) seedlings contained both D- and L-myo-[3H]inositol 1,2,4,5,6-pentakisphosphate (which was characterized by 31P and two-dimensional proton n.m.r.) and D- and/or L-myo-[3H]inositol 1,2,3,4,5-pentakisphosphate; HL60 cells contained myo-[3H]inositol 1,3,4,5,6-pentakisphosphate (in a 500-fold excess over the other species), myo-[3H]inositol 1,2,3,4,6-pentakisphosphate and D- and/or L-myo-[3H]inositol 1,2,4,5,6-pentakisphosphate; and NG-115-401L-C3 cells contained myo-[3H]inositol 1,3,4,5,6-pentakisphosphate (in a 100-fold excess over the other species), D- and/or L-myo-[3H]inositol 1,2,4,5,6-pentakisphosphate, myo-[3H]inositol 1,2,3,4,6-pentakisphosphate and D- and/or L-myo-[3H]inositol 1,2,3,4,5-pentakisphosphate. 2. Multiple soluble ATP-dependent myo-inositol pentakisphosphate kinase activities have been detected in slime mould, rat brain and germinating mung-bean seedling homogenates. In slime-mould cytosolic fractions, the three myo-inositol pentakisphosphates that were present in intact slime moulds could be phosphorylated to myo-[3H]inositol hexakisphosphate: the relative first-order rate constants for these reactions were, in the order listed above, 1:8:31 respectively (with first-order rate constants in the intact cell of 0.1, 0.8 and 3.1 s-1, assuming a cytosolic protein concentration of 50 mg/ml), and the Km values of the activities for their respective inositol phosphate substrates (in the presence of 5 mM-ATP) were 1.6 microM, 3.8 microM and 1.4 microM. At least two forms of myo-inositol pentakisphosphate kinase activity could be resolved from a slime-mould cytosolic fraction by both pharmacological and chromatographic criteria. Rat brain cytosol and a soluble fraction derived from germinating mung-bean seedlings could phosphorylate myo-inositol D/L-1,2,4,5,6-, D/L-1,2,3,4,5-, 1,2,3,4,6- and 1,3,4,5,6-pentakisphosphates to myo-inositol hexakisphosphate: the relative first-order rate constants were 57:27:77:1 respectively for brain cytosol (with first-order rate constants in the intact cell of 0.0041, 0.0019, 0.0056 and 0.000073 s-1 respectively, assuming a cytosolic protein concentration of 50 mg/ml) and 1:11:12:33 respectively for mung-bean cytosol (with first-order rate constants in a supernatant fraction with a protein concentration of 10 mg/ml of 0.0002, 0.0022, 0.0024 and 0.0066 s-1 respectively).
Resumo:
Technological innovation has been widely studied: however surprisingly little is known about the experience of managing the process. Most reports tend to be generalistic and/or prescriptive whereas it is argued that multiple sources of variation in the process limit the value of these. A description of the innovation process is given together with a presentation of what is knovrn from existing studies. Gaps identified in this area suggest that a variety of organisational influences are important and an attempt is made to identify some of these at individual, group and organisational level. A simple system model of the innovation management process is developed. Further investigation of the influence of these factors was made possible through an extended on-site case study. Methodology for this based upon participant observation coupled wth a wide and flexible range of techniques is described. Evidence is presented about many aspects of the innovation process from a number of different levels and perspectives: the attempt is to demonstrate the extent to which variation due to contingent influences takes place. It is argued that problems identified all relate to the issue of integration. This theme is also developed from an analytical viewoint and it is suggested that organisational response to increases in complexity in the external environment will be to match them with internal complexity. Differentiation of this kind will require extensive and flexible integration, especially in those inherently uncertain areas associated with innovation. Whilst traditionally a function of management, it is argued that integration needs have increased to the point where a new specialism is required. The concept of integration specialist is developed from this analysis and attempts at simple integrative change during the research are described. Finally a strategy for integration - or rather for building in integrative capability - ln the organisation studied is described.
Resumo:
This thesis has focused on three key areas of interest for femtosecond micromachining and inscription. The first area is micromachining where the work has focused on the ability to process highly repeatable, high precision machining with often extremely complex geometrical structures with little or no damage. High aspect ratio features have been demonstrated in transparent materials, metals and ceramics. Etch depth control was demonstrated especially in the work on phase mask fabrication. Practical chemical sensing and microfluidic devices were also fabricated to demonstrate the capability of the techniques developed during this work. The second area is femtosecond inscription. Here, the work has utilised the non-linear absorption mechanisms associated with femtosecond pulse-material interactions to create highly localised refractive index changes in transparent materials to create complex 3D structures. The techniques employed were then utilised in the fabrication of Phase masks and Optical Coherence Tomography (OCT) phantom calibration artefacts both of which show the potential to fill voids in the development of the fields. This especially the case for the OCT phantoms where there exists no previous artefacts of known shape, allowing for the initial specification of parameters associated with the quality of OCT machines that are being taken up across the world in industry and research. Finally the third area of focus was the combination of all of the techniques developed through work in planar samples to create a range of artefacts in optical fibres. The development of techniques and methods for compensating for the geometrical complexities associated with working with the cylindrical samples with varying refractive indices allowed for fundamental inscription parameters to be examined, structures for use as power monitors and polarisers with the optical fibres and finally the combination of femtosecond inscription and ablation techniques to create a magnetic field sensor with an optical fibre coated in Terfenol-D with directional capability. Through the development of understanding, practical techniques and equipment the work presented here demonstrates several novel pieces of research in the field of femtosecond micromachining and inscription that has provided a broad range of related fields with practical devices that were previously unavailable or that would take great cost and time to facilitate.
Resumo:
A system for the NDI' testing of the integrity of conposite materials and of adhesive bonds has been developed to meet industrial requirements. The vibration techniques used were found to be applicable to the development of fluid measuring transducers. The vibrational spectra of thin rectangular bars were used for the NDT work. A machined cut in a bar had a significant effect on the spectrum but a genuine crack gave an unambiguous response at high amplitudes. This was the generation of fretting crack noise at frequencies far above that of the drive. A specially designed vibrational decrement meter which, in effect, measures mechanical energy loss enabled a numerical classification of material adhesion to be obtained. This was used to study bars which had been flame or plasma sprayed with a variety of materials. It has become a useful tool in optimising coating methods. A direct industrial application was to classify piston rings of high performance I.C. engines. Each consists of a cast iron ring with a channel into which molybdenum, a good bearing surface, is sprayed. The NDT classification agreed quite well with the destructive test normally used. The techniques and equipment used for the NOT work were applied to the development of the tuning fork transducers investigated by Hassan into commercial density and viscosity devices. Using narrowly spaced, large area tines a thin lamina of fluid is trapped between them. It stores a large fraction of the vibrational energy which, acting as an inertia load reduces the frequency. Magnetostrictive and piezoelectric effects together or in combination enable the fork to be operated through a flange. This allows it to be used in pipeline or 'dipstick' applications. Using a different tine geometry the viscosity loading can be predoninant. This as well as the signal decrement of the density transducer makes a practical viscometer.
Resumo:
The recent history of small shop and independent retailing has been one of decline. The most desirable form of assistance is the provision of information which will increase the efficiency model of marketing mix effeciveness which may be applied in small scale retailing. A further aim is to enhance theoretical development in the marketing field. Recent changes in retailing have affected location, product range, pricing and promotion practices. Although a large number of variables representing aspects of the marketing mix may be identified, it is not possible, on the basis of currently available information, to quantify or rank them according to their effect on sales performance. In designing a suitable study a major issue is that of access to a suitable representative sample of small retailers. The publish nature of the retail activities involved facilitates the use of a novel observation approach to data collection. A cross-sectional survey research design was used focussing on a clustered random sample of greengrocers and gent's fashion outfitters in the West Midlands. Linear multiple regression was the main analytical technique. Powerful regression models were evolved for both types of retailing. For greengrocers the major influences on trade are pedestrian traffic and shelf display space. For gent's outfitters they are centrality-to-other shopping, advertising and shelf display space. The models may be utilised by retailers to determine the relative strength of marketing mix variables. The level of precision is not sufficient to permit cost benefit analysis. Comparison of the findings for the two distinct kinds of business studied suggests an overall model of marketing mix effectiveness might be based on frequency of purchase, homogeneity of the shopping environment, elasticity of demand and bulk characteristics of the good sold by a shop.
Resumo:
This study has concentrated on the development of an impact simulation model for use at the sub-national level. The necessity for the development of this model was demonstrated by the growth of local economic initiatives during the 1970's, and the lack of monitoring and evaluation exercise to assess their success and cost-effectiveness. The first stage of research involved the confirmation that the potential for micro-economic and spatial initiatives existed. This was done by identifying the existence of involuntary structural unemployment. The second stage examined the range of employment policy options from the macroeconomic, micro-economic and spatial perspectives, and focused on the need for evaluation of those policies. The need for spatial impact evaluation exercise in respect of other exogenous shocks, and structural changes was also recognised. The final stage involved the investigation of current techniques of evaluation and their adaptation for the purpose in hand. This led to a recognition of a gap in the armoury of techniques. The employment-dependency model has been developed to fill that gap, providing a low-budget model, capable of implementation at the small area level and generating a vast array of industrially disaggregate data, in terms of employment, employment-income, profits, value-added and gross income, related to levels of United Kingdom final demand. Thus providing scope for a variety of impact simulation exercises.
Resumo:
The principles of High Performance Liquid Chromatography (HPLC) and pharmacokinetics were applied to the use of several clinically-important drugs at the East Birmingham Hospital. Amongst these was gentamicin, which was investigated over a two-year period by a multi-disciplinary team. It was found that there was considerable intra- and inter-patient variation that had not previously been reported and the causes and consequences of such variation were considered. A detailed evaluation of available pharmacokinetic techniques was undertaken and 1- and 2-compartment models were optimised with regard to sampling procedures, analytical error and model-error. The implications for control of therapy are discussed and an improved sampling regime is proposed for routine usage. Similar techniques were applied to trimethoprim, assayed by HPLC, in patients with normal renal function and investigations were also commenced into the penetration of drug into peritoneal dialysate. Novel assay techniques were also developed for a range of drugs including 4-aminopyridine, chloramphenicol, metronidazole and a series of penicillins and cephalosporins. Stability studies on cysteamine, reaction-rate studies on creatinine-picrate and structure-activity relationships in HPLC of aminopyridines are also reported.