7 resultados para Orbital Implants

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The whole set of the nickel(II) complexes with no derivatized edta-type hexadentate ligands has been investigated from their structural and electronic properties. Two more complexes have been prepared in order to complete the whole set: trans(O5)-[Ni(ED3AP)]2- and trans(O5O6)-[Ni(EDA3P)]2- complexes. trans(O5) geometry has been verified crystallographically and trans(O5O6) geometry of the second complex has been predicted by the DFT theory and spectral analysis. Mutual dependance has been established between: the number of the five-membered carboxylate rings, octahedral/tetrahedral deviation of metal-ligand/nitrogen-neighbour-atom angles and charge-transfer energies (CTE) calculated by the Morokuma’s energetic decomposition analysis; energy of the absorption bands and HOMO–LUMO gap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is concerned with gravity field recovery from low-low satellite to satellite range rate data. An improvement over a coplanar mission is predicted in the errors associated with certain parts of the geopotential by the separation of the orbital planes of the two satellites. Using Hill's equations an analytical scheme to model the range rate residuals is developed. It is flexible enough to model equally well the residuals between pairs of satellites in the same orbital plane or whose planes are separated in right ascension. The possible benefits of such an orientation to gravity field recovery from range rate data can therefore be analysed, and this is done by means of an extensive error analysis. The results of this analysis show that for an optimal planar mission improvements can be made by separating the satellites in right ascension. Gravity field recoveries are performed in order to verify and gauge the limitations of the analytical model, and to support the results of the error analysis. Finally the possible problem of the differential decay rates of two satellites due to the diurnal bulge are evaluated.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fate of vitamin E and the formation and identification of its transformation products were investigated at different stages of the manufacturing process of commercially produced cross-linked (by γ-irradiation) UHMWPE stabilised with vitamin E (vitamin E infused-post irradiation) used for tibia-components (as articulating surfaces) in total knee arthroplasty (total knee replacement). Vitamin E (α-tocopherol) and its transformation products were extracted from microtomed Tibia films and the different products were separated, isolated, purified using high performance liquid chromatography (HPLC), and characterised by spectroscopic methods and LC-MS. The amount of vitamin E and that of the products formed in the different Tibia samples and in their extracts were also quantified using FTIR and HPLC analysis and calibration curves. Thorough analysis of the Tibia extracts has shown that a number of vitamin E transformation products were formed at different concentrations at two selected stages of the implant manufacturing process that is before and after sterilisation by γ-irradiation. The identified products were found to correspond mainly to different stereoisomeric forms of a small number of vitamin E transformation products. Most of the observed products were of dimeric and trimeric nature with their identity confirmed through a detailed study of their spectral and chromatographic characteristics. It was found that the products of vitamin E, prior to the sterilisation step but after the crosslinking and doping of vitamin E, were mainly the dihydroxydimers and trimers (Tibia samples at this stage are referred to as “Tibia-VEPE”). After sterilisation and completion of the manufacturing process, additional dimers of vitamin E were also formed (Tibia samples at this stage are referred to as ‘Tibia-VEPE-Sterile’), Furthermore, two tocopherol-derived aldehydes (aldehyde 5-formyl-γ-tocopherol and aldehyde 7-formyl-γ-tocopherol) were also formed but at very low concentrations especially in the Tibia-VEPE-Sterile samples. The question of whether vitamin E becomes chemically reacted (grafted) onto the polymer matrix during the manufacturing process of the Tibia is also addressed.