25 resultados para Ocular Response Analyzer

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis investigates the ocular response to silicone-hydrogel (SiH) contact lens wear, a relatively new contact lens material that has a higher modulus of rigidity and different surface coating than used in conventional hydrogel materials. The properties of SiH materials differ significantly from conventional hydrogels and, using subjective and objective means of assessment, the thesis examines how these properties affect reflection and biometry, ocular physiology, tear film characteristics, symptomatology, adverse events and complications. A range of standard and newly designed investigative techniques were employed, and latter involving novel imaging techniques, for the objective assessment of physiological changes which occur with contact lens wear. The study is the first to combine these techniques with biochemical analyses of the tear film composition. Forty-seven subjects were fitted with SiH lenses and randomly allocated to one of the two materials currently on the market (Lotrafilcon A or Balafilcon A) on an either daily or continuous wear basis. An additional control group of 14 age-matched non-contact lens wearers were monitored over the same period. Measurements were taken before and 1, 3, 6, 12 and 18 months after initial fitting. The findings reported in this thesis will enable contact lens practitioners and manufacturers to understand further the optical, physiological and biochemical nature of the ocular response to SiH contact lenses and hence facilitate the development of this important generation of contact lens material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the practicality and accuracy of tonometers used in routine clinical practice for established keratoconus (KC). Methods: This was a prospective study of 118 normal and 76 keratoconic eyes where intraocular pressure (IOP) was measured in random order using the Goldman applanation tonometer (GAT), Pascal dynamic contour tonometer (DCT), Reichert ocular response analyser (ORA) and TonoPen XL tonometer. Corneal hysteresis (CH) and corneal resistance factor (CRF), as calculated by the ORA, were recorded. Central corneal thickness (CCT) was measured using an ultrasound pachymeter. Results: The difference in IOP values between instruments was highly significant in both study groups (p<0.001). All other IOP measures were significantly higher than those for GAT, except for the Goldmann-correlated IOP (average of the two applanation pressure points) (IOPg) as measured by ORA in the control group and the CH-corrected IOP (corneal-compensated IOP value) (IOPcc) measures in the KC group. CCT, CH and CRF were significantly less in the KC group (p<0.001). Apart from the DCT, all techniques tended to measure IOP higher in eyes with thicker corneas. Conclusion: The DCT and the ORA are currently the most appropriate tonometers to use in KC for the measurement of IOPcc. Corneal factors such as CH and CRT may be of more importance than CCT in causing inaccuracies in applanation tonometry techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biotribology is essentially the study of friction, lubrication and wear in biological systems. The area has been widely studied in relation to the behaviour of synovial joints and the design and behaviour of hip joint prostheses, but only in the last decade have serious studies been extended to the eye. In the ocular environment - as distinct from articular joints - wear is not a major factor. Both lubrication and friction are extremely important, however; this is particularly the case in the presence of the contact lens, which is a medical device important not only in vision correction but also as a therapeutic bandage for the compromised cornea. This chapter describes the difficulty in replicating experimental conditions that accurately reflect the complex nature of the ocular environment together with the factors such as load and rate of travel of the eyelid, which is the principal moving surface in the eye. Results obtained across a range of laboratories are compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To perform advanced analysis of the corneal deformation response to air pressure in keratoconics compared with age- and sex-matched controls. METHODS: The ocular response analyzer was used to measure the air pressure-corneal deformation relationship of 37 patients with keratoconus and 37 age (mean 36 ± 10 years)- and sex-matched controls with healthy corneas. Four repeat air pressure-corneal deformation profiles were averaged, and 42 separate parameters relating to each element of the profiles were extracted. Corneal topography and pachymetry were performed with the Orbscan II. The severity of the keratoconus was graded based on a single metric derived from anterior corneal curvatures, difference in astigmatism in each meridian, anterior best-fit sphere, and posterior best-fit sphere. RESULTS: Most of the biomechanical characteristics of keratoconic eyes were significantly different from normal eyes (P <0.001), especially during the initial corneal applanation. With increasing keratoconus severity, the cornea was thinner (r = -0.407, P <0.001), the speed of corneal concave deformation past applanation was quicker (dive; r = -0.314, P = 0.01), and the tear film index was lower (r = -0.319, P = 0.01). The variance in keratoconus severity could be accounted for by the corneal curvature and central corneal thickness (r = 0.80) with biomechanical characteristics contributing an additional 4% (total r = 0.84). The area under the receiver operating characteristic curve was 0.919 ± 0.025 for keratometry alone, 0.965 ± 0.014 with the addition of pachymetry, and 0.972 ± 0.012 combined with ocular response analyzer biomechanical parameters. CONCLUSIONS: Characteristics of the air pressure-corneal deformation profile are more affected by keratoconus than the traditionally extracted corneal hysteresis and corneal resistance factors. These biomechanical metrics slightly improved the detection and severity prediction of keratoconus above traditional keratometric and pachymetric assessment of corneal shape.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The ability to measure ocular surface temperature (OST) with thermal imaging offers potential insight into ocular physiology that has been acknowledged in the literature. The TH7102MX thermo-camera (NEC San-ei, Japan) continuously records dynamic information about OST without sacrificing spatial resolution. Using purpose-designed image analysis software, it was possible to select and quantify the principal components of absolute temperature values and the magnitude plus rate of temperature change that followed blinking. The techniques was examined for repeatability, reproducibility and the effects of extrinsic factors: a suitable experimental protocol was thus developed. The precise source of the measured thermal radiation has previously been subject toe dispute: in this thesis, the results of a study examining the relationships between physical parameters of the anterior eye and OST, confirmed a principal role for the tear film in OST. The dynamic changes in OST were studied in a large group of young subjects: quantifying the post-blink changes in temperature with time also established a role for tear flow dynamics in OST. Using dynamic thermography, the effects of hydrogel contact lens wear on OST were investigated: a model eye for in vivo work, and both neophyte and adapted contact lens wearers for in vivo studies. Significantly greater OST was observed in contact lens wearers, particularly with silicone hydrogel lenses compared to etafilcon A, and tended to be greatest when lenses had been worn continuously. This finding is important to understanding the ocular response to contact lens wear. In a group of normal subjects, dynamic thermography appeared to measure the ocular response to the application of artificial tear drops: this may prove to be a significant research and clinical tool.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Since the initial launch of silicone hydrogel lenses, there has been a considerable broadening in the range of available commercial material properties. The very mobile silicon–oxygen bonds convey distinctive surface and mechanical properties on silicone hydrogels, in which advantages of enhanced oxygen permeability, reduced protein deposition, and modest frictional interaction are balanced by increased lipid and elastic response. There are now some 15 silicone hydrogel material variants available to practitioners; arguably, the changes that have taken place have been strongly influenced by feedback based on clinical experience. Water content is one of the most influential properties, and the decade has seen a progressive rise from lotrafilcon-A (24%) to efrofilcon-A (74%). Moduli have decreased over the same period from 1.4 to 0.3 MPa, but not solely as a result of changes in water content. Surface properties do not correlate directly with water content, and ingenious approaches have been used to achieve desirable improvements (e.g., greater lubricity and lower contact angle hysteresis). This is demonstrated by comparing the hysteresis value of the earliest (lotrafilcon-A, >40°) and most recent (delefilcon-A, <10°) coated silicone hydrogels. Although wettability is important, it is not of itself a good predictor of ocular response because this involves a much wider range of physicochemical and biochemical factors. The interference of the lens with ocular dynamics is complex leading separately to tissue–material interactions involving anterior and posterior lens surfaces. The biochemical consequences of these interactions may hold the key to a greater understanding of ocular incompatibility and end of day discomfort.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The thesis investigates the relationship between the biomechanical properties of the anterior human sclera and cornea in vivo using Schiotz tonometry (ST), rebound tonometry (RBT, iCare) and the Ocular Response Analyser (ORA, Reichert). Significant differences in properties were found to occur between scleral quadrants. Structural correlates for the differences were examined using Partial Coherent Interferometry (IOLMaster, Zeiss), Optical Coherent tomography (Visante OCT), rotating Scheimpflug photography (Pentacam, Oculus) and 3-D Magnetic Resonance Imaging (MRI). Subject groups were employed that allowed investigation of variation pertaining to ethnicity and refractive error. One hundred thirty-five young adult subjects were drawn from three ethnic groups: British-White (BW), British-South-Asian (BSA) and Hong-Kong-Chinese (HKC) comprising non-myopes and myopes. Principal observations: ST demonstrated significant regional variation in scleral resistance a) with lowest levels at quadrant superior-temporal and highest at inferior-nasal; b) with distance from the limbus, anterior locations showing greater resistance. Variations in resistance using RBT were similar to those found with ST; however the predominantly myopic HKC group had a greater overall mean resistance when compared to the BW-BSA group. OCT-derived scleral thickness measurements indicated the sclera to be thinner superiorly than inferiorly. Thickness varied with distance from the corneolimbal junction, with a decline from 1 to 2 mm followed by a successive increase from 3 to 7 mm. ORA data varied with ethnicity and refractive status; whilst axial length (AL) was associated with corneal biometrics for BW-BSA individuals it was associated with IOP in the HKC individuals. Complex interrelationships were found between ORA Additional-Waveform-Parameters and biometric data provided by the Pentacam. OCT indicated ciliary muscle thickness to be greater in myopia and more directly linked to posterior ocular volume (from MRI) than AL. Temporal surface areas (SAs, from MRI) were significantly smaller than nasal SAs in myopic eyes; globe bulbosity (from MRI) was constant across quadrants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE. To assess systemic and ocular vascular reactivity in response to warm and cold provocation in untreated patients with primary open-angle glaucoma and normal control subjects. METHODS. Twenty-four patients with primary open-angle glaucoma and 22 normal control subjects were subjected to a modified cold pressor test involving immersion of the right hand in 40°C warm water followed by 4°C cold water exposure, and finger and ocular blood flow were assessed by means of peripheral laser Doppler flowmetry and retinal flowmetry, respectively. Finger and body temperature as well as intraocular pressure, systemic blood pressure, systemic pulse pressure, heart rate, and ocular perfusion pressure were also monitored. RESULTS. The patients with glaucoma demonstrated an increase in diastolic blood pressure (P = 0.023), heart rate (P = 0.010), and mean ocular perfusion pressure (P = 0.039) during immersion of the tested hand in 40°C water. During cold provocation, the patients demonstrated a significant decrease in finger (P = 0.0003) and ocular blood flow (the parameter velocity measured at the temporal neuroretinal rim area; P = 0.021). Normal subjects did not demonstrate any blood flow or finger temperature changes during immersion of the tested hand in 40°C water (P > 0.05); however, they exhibited increases in systolic blood pressure (P = 0.034) and pulse pressure (P = 0.0009) and a decrease in finger blood flow (P = 0.0001) during cold provocation. In normal subjects, the ocular blood flow was unchanged during high- and low-temperature challenge. CONCLUSIONS. Cold provocation elicits a different blood pressure, and ocular blood flow response in patients with primary open-angle glaucoma compared with control subjects. These findings suggest a systemic autonomic failure and ocular vascular dysregulation in POAG patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To determine the response of retinal vessels to differing durations of flicker light (FL) sitmulation. Methods: We recorded retinal arterial and venous vessel dilation to 12.5 Hz flicker light provocation (Retinal Vessel Analyzer, Imedos Systems) of varying duration (5, 7, 10 and 20 seconds) in twelve healthy young individuals (age range 26-45 yrs). All participants underwent a full ocular examination including intraocular pressure and blood pressure measurements. Results: Maximum dilation (MD) did not show a significant dependence on flicker duration in arteries whereas maximum constriction (MC) did. However, in veins MD significantly increased with flicker duration. Approximately 80-90% of MD in arteries is reached within 10 seconds of flicker light stimulation. Conclusions: The vast majority of arterial dilatory capacity is reached within 10 seconds of flicker light stimulation even though venous dilation continues strongly. Since the MC of arteries shows a significant dependence on flicker duration measurements at two different durations can provide more information about the retinal vascular system than at a single flicker duration alone.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. © 2009 Acta Ophthalmol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To investigate objectively and noninvasively the role of cognitive demand on autonomic control of systemic cardiovascular and ocular accommodative responses in emmetropes and myopes of late-onset. METHODS. Sixteen subjects (10 men, 6 women) aged between 18 and 34 years (mean ± SD: 22.6 ± 4.4 years), eight emmetropes (EMMs; mean spherical equivalent [MSE] refractive error ± SD: 0.05 ± 0.24 D) and eight with late-onset myopia (LOMs; MSE ± SD: -3.66 ± 2.31 D) participated in the study. Subjects viewed stationary numerical digits monocularly within a Badal optical system (at both 0.0 and -3.0 D) while performing a two-alternative, forced-choice paradigm that matched cognitive loading across subjects. Five individually matched cognitive levels of increasing difficulty were used in random order for each subject. Five 20-second, continuous-objective recordings of the accommodative response measured with an open-view infrared autorefractor were obtained for each cognitive level, whereas simultaneous measurement of heart rate was continuously recorded with a finger-mounted piezoelectric pulse transducer for 5 minutes. Fast Fourier transformation of cardiovascular function allowed the relative power of the autonomic components to be assessed in the frequency domain, whereas heart period gave an indication of the time-domain response. RESULTS. Increasing the cognitive demand led to a significant reduction in the accommodative response in all subjects (0.0 D: by -0.35 ± 0.33 D; -3.0 D: by -0.31 ± 0.40 D, P < 0.001). The greater lag of LOMs compared with EMMs was not significant (P = 0.07) at both distance (0.38 ± 0.35 D) and near (0.14 ± 0.42 D). Mean heart period reduced with increasing levels of workload (P < 0.0005). LOMs exhibited a relative elevation in sympathetic system activity compared to EMMs. Within refractive groups, however, accommodative shifts with increasing cognition correlated with parasympathetic activity (r = 0.99, P < 0.001), more than with sympathetic activity (r = 0.62, P > 0.05). CONCLUSIONS. In an equivalent workload paradigm, increasing cognitive demand caused a reduction in accommodative response that was attributable principally to a concurrent reduction in the relative power of the parasympathetic component of the autonomic nervous system (ANS). The disparity in accommodative response between EMMs and LOMs, however, appears to be augmented by changes in the sympathetic nervous component of the systemic ANS. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the hypothesis that objective measures of open- and closed-loop ocular accommodation are related to systemic cardiovascular function, and ipso facto autonomic nervous system activity. METHODS: Sixty subjects (29 male; 31 female) varying in age from 18 to 33 years (average: 20.3 +/- 2.9 years) with a range of refractive errors [mean spherical equivalent (MSE): -7.12 to +1.82 D] participated in the study. Five 20-s continuous objective recordings of the accommodative response, measured with an open-view IR autorefractor (Shin-Nippon SRW-5000), were obtained for a variety of open- and closed-loop accommodative demands while simultaneous continuous measurement of heart rate was recorded with a finger-mounted piezo-electric pulse transducer for 5 min. Fast Fourier Transformation of cardiovascular function allowed the absolute and relative power of the autonomic components to be assessed in the frequency-domain, whereas heart period gave an indication of the time-domain response. RESULTS: Increasing closed-loop accommodative demand led to a concurrent increase in heart rate of approximately 2 beats/min for a 4.0 D increase in accommodative demand. The increase was attributable to a reduction in the absolute (p < 0.05) and normalised (p < 0.001) input of the systemic parasympathetic nervous system, and was unaffected by refractive group. The interaction with refractive group failed to reach significance. CONCLUSIONS: For sustained accommodation effort, the data demonstrate covariation between the oculomotor and cardiovascular systems which implies that a near visual task can significantly influence cardiovascular behaviour. Accommodative effort alone, however, is not a sufficient stimulus to induce autonomic differences between refractive groups. The data suggest that both the oculomotor and cardiovascular systems are predominantly attributable to changes in the systemic parasympathetic nervous system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hydrogels, water swollen polymer matrices, have been utilised in many biomedical applications, as there is the potential to manipulate the properties for a given application by changing the chemical structure of the constituent monomers The eye provides an excellent site to examne the interaction between a synthetic material and a complex biological fluid without invasive surgery. There is a need for the development of new synthetic hydrogels for use in the anterior eye, Three applications of hydrogels in the eye were considered in this thesis. For some patients, the only hope of any visual improvement lies in the use of an artificial cornea, or keratoprosthesis, Preliminary investigations of a series of simple homogeneous hydrogel copolymers revealed that the mechanical properties required to withstand surgery and in eye stresses, were not achieved This lead to work on the development of semi-interpenetrating polymer networks based on the aforementioned copolymers, Manufacture of the device and cell response were also studied. Lasers have been employed in ocular surgery to correct refractive defects. If an irregular surface is ablated, an irregular surface is obtained. A hydrogel system was investigated that could be applied to the eye prior to ablation to create a smooth surface. Factors that may influence ablation rate were explored, Soft contact lenses can be used as a probe to study the interaction between synthetic materials and the biological constituents of tears. This has lead to the development of many sensitive analytical techniques for protein and lipid deposition, one of which is fluorescence spectrophotometry. Various commercially available soft contact lenses were worn for different periods of time and then analysed for protein and lipid deposition using fluorescence spectrophotometry, The influence of water content, degree of ionicity and the lens material on the level and type of deposition was investigated.