12 resultados para Objective measure

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To develop an objective measure to enable hospital Trusts to compare their use of antibiotics. Design: Self-completion, postal questionnaire with telephone follow up. Sample: 4 hospital trusts in the English Midlands. Results: The survey showed that it was possible to collect data concerning the number of Defined Daily Doses (DDD's) of quinolone antibiotic dispensed per Finished Consultant Episode (FCE) in each Trust.. In the 4 trusts studied the mean DDD/FCE was 0.197 (range 0.117 to 0.258). This indicates that based on a typical course length of 5 days, 3.9% of patient episodes resulted in the prescription of a quinolone antibiotic. Antibiotic prescribing control measures in each Trust were found to be comparable. Conclusion: The measure will enable Trusts to objectively compare their usage of quinolone antibiotics and use this information to carry out clinical audit should differences be recorded. This is likely to be applicable to other groups of antibiotics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Journal ranking studies have generally adopted citation techniques or academic perceptions as the basis for assessing journal quality. They have traditionally been a source of information about potential research outlets, new journals, and an aid to developing a consensus about the relative merit of publications for promotion decisions. The aim of our research is to address specific shortcomings in the conventional literature and construct an alternative view of how we might more appropriately assess journal ‘quality’. We attempt to engage with the conventional literature by applying an approach that does not privilege either citation techniques or academic perceptions. We have adopted from Zeff (1996) an objective measure of academic journal library holdings, which Zeff describes as a ‘market test’. Our construct provides evidence of an important difference in journal holdings for the Australasian region that could significantly influence further research on journal quality. The method itself is entirely mundane but may be considered to reflect a complex of historic and more contemporary variables which impact on academic and administrative decisions, influencing the makeup of academic library holdings and providing a proxy for journal ‘quality’.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The tendency to hear a tone sequence as 2 or more streams (segregated) builds up, but a sudden change in properties can reset the percept to 1 stream (integrated). This effect has not hitherto been explored using an objective measure of streaming. Stimuli comprised a 2.0-s fixed-frequency inducer followed by a 0.6-s test sequence of alternating pure tones (3 low [L]-high [H] cycles). Listeners compared intervals for which the test sequence was either isochronous or the H tones were slightly delayed. Resetting of segregation should make identifying the anisochronous interval easier. The HL frequency separation was varied (0-12 semitones), and properties of the inducer and test sequence were set to the same or different values. Inducer properties manipulated were frequency, number of onsets (several short bursts vs. one continuous tone), tone:silence ratio (short vs. extended bursts), level, and lateralization. All differences between the inducer and the L tones reduced temporal discrimination thresholds toward those for the no-inducer case, including properties shown previously not to affect segregation greatly. Overall, it is concluded that abrupt changes in a sequence cause resetting and improve subsequent temporal discrimination. (PsycINFO Database Record © 2009 APA, all rights reserved)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main objective of the project is to enhance the already effective health-monitoring system (HUMS) for helicopters by analysing structural vibrations to recognise different flight conditions directly from sensor information. The goal of this paper is to develop a new method to select those sensors and frequency bands that are best for detecting changes in flight conditions. We projected frequency information to a 2-dimensional space in order to visualise flight-condition transitions using the Generative Topographic Mapping (GTM) and a variant which supports simultaneous feature selection. We created an objective measure of the separation between different flight conditions in the visualisation space by calculating the Kullback-Leibler (KL) divergence between Gaussian mixture models (GMMs) fitted to each class: the higher the KL-divergence, the better the interclass separation. To find the optimal combination of sensors, they were considered in pairs, triples and groups of four sensors. The sensor triples provided the best result in terms of KL-divergence. We also found that the use of a variational training algorithm for the GMMs gave more reliable results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sustained driving in older age has implications for quality of life and mental health. Studies have shown that despite the recognised importance of driving in maintaining health and social engagement, many women give up driving prematurely or adopt self-imposed restrictive driving practices. Emotional responses to driving have been implicated in these decisions. This research examined the effect of risk perception and feelings of vulnerability on women’s driving behaviour across the lifespan. It also developed and tested a modified theory of planned behaviour intervention to positively affect driving habits. The first two studies (N=395) used quantitative analysis to model driving behaviours affected by risk perception and feelings of vulnerability, and established that feelings of vulnerability do indeed affect women’s driving behaviour, specifically resulting in increases in driving avoidance and the adoption of maladaptive driving styles. Further, that self-regulation, conceptualised as avoidance, is used by drivers across the lifespan. Qualitative analysis of focus group data (N=48) in the third study provided a deeper understanding of the variations in coping behaviours adopted by sub-groups of drivers and extended the definition of self-regulation to incorporate adaptive coping strategies. The next study (N=64) reported the construction and preliminary validation of the novel self-regulation index (SRI) to measure wider self-regulation behaviours using an objective measure of driving behaviour, a simulated driving task. The understanding gained from the formative research was used in the final study, an extended theory of planned behaviour intervention to promote wider self-regulation behaviour, measured using the previously validated self-regulation index. The intervention achieved moderate success with changes in affective attitude and normative beliefs as well as self-reported behaviour. The results offer promise for self-regulation, incorporating a spectrum of planning and coping behaviours, to be used as a mechanism to assist drivers in achieving their personal mobility goals whilst promoting safe driving.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To assess the visual performance and subjective experience of eyes implanted with a new bi-aspheric, segmented, multifocal intraocular lens: the Mplus X (Topcon Europe Medical, Capelle aan den IJssel, Netherlands). METHODS: Seventeen patients (mean age: 64.0 ± 12.8 years) had binocular implantation (34 eyes) with the Mplus X. Three months after the implantation, assessment was made of: manifest refraction; uncorrected and corrected distance visual acuity; uncorrected and distance corrected near visual acuity; defocus curves in photopic conditions; contrast sensitivity; halometry as an objective measure of glare; and patient satisfaction with unaided near vision using the Near Acuity Visual Questionnaire. RESULTS: Mean residual manifest refraction was -0.13 ± 0.51 diopters (D). Twenty-five eyes (74%) were within a mean spherical equivalent of ±0.50 D. Mean uncorrected distance visual acuity was +0.10 ± 0.12 logMAR monocularly and 0.02 ± 0.09 logMAR binocularly. Thirty-two eyes (94%) could read 0.3 or better without any reading correction and all patients could read 0.3 or better with a reading correction. Mean monocular uncorrected near visual acuity was 0.18 ± 0.16 logMAR, improving to 0.15 ± 0.15 logMAR with distance correction. Mean binocular uncorrected near visual acuity was 0.11 ± 0.11 logMAR, improving to 0.09 ± 0.12 logMAR with distance correction. Mean binocular contrast sensitivity was 1.75 ± 0.14 log units at 3 cycles per degree, 1.88 ± 0.20 log units at 6 cycles per degree, 1.66 ± 0.19 log units at 12 cycles per degree, and 1.11 ± 0.20 log units at 18 cycles per degree. Mean binocular and monocular halometry showed a glare profile of less than 1° of debilitating light scatter. Mean Near Acuity Visual Questionnaire Rasch score (0 = no difficulty, 100 = extreme difficulty) for satisfaction for near vision was 20.43 ± 14.64 log-odd units. CONCLUSIONS: The Mplus X provides a good visual outcome at distance and near with minimal dysphotopsia. Patients were very satisfied with their uncorrected near vision. © SLACK Incorporated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims - To develop a method that prospectively assesses adherence rates in paediatric patients with acute lymphoblastic leukaemia (ALL) who are receiving the oral thiopurine treatment 6-mercaptopurine (6-MP). Methods - A total of 19 paediatric patients with ALL who were receiving 6-MP therapy were enrolled in this study. A new objective tool (hierarchical cluster analysis of drug metabolite concentrations) was explored as a novel approach to assess non-adherence to oral thiopurines, in combination with other objective measures (the pattern of variability in 6-thioguanine nucleotide erythrocyte concentrations and 6-thiouric acid plasma levels) and the subjective measure of self-reported adherence questionnaire. Results - Parents of five ALL patients (26.3%) reported at least one aspect of non-adherence, with the majority (80%) citing “carelessness at times about taking medication” as the primary reason for non-adherence followed by “forgetting to take the medication” (60%). Of these patients, three (15.8%) were considered non-adherent to medication according to the self-reported adherence questionnaire (scored ≥ 2). Four ALL patients (21.1%) had metabolite profiles indicative of non-adherence (persistently low levels of metabolites and/or metabolite levels clustered variably with time). Out of these four patients, two (50%) admitted non-adherence to therapy. Overall, when both methods were combined, five patients (26.3%) were considered non-adherent to medication, with higher age representing a risk factor for non-adherence (P < 0.05). Conclusions - The present study explored various ways to assess adherence rates to thiopurine medication in ALL patients and highlighted the importance of combining both objective and subjective measures as a better way to assess adherence to oral thiopurines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In industrialised countries age-related macular disease (ARMD) is the leading cause of visual loss in older people. Because oxidative stress is purported to be associated with an increased risk of disease development the role of antioxidant supplementation is of interest. Lutein is a carotenoid antioxidant that accumulates within the retina and is thought to filter blue light. Increased levels of lutein have been associated with reduced risk of developing ARMD and improvements in visual and retinal function in eyes with ARMD. The aim of this randomised controlled trial (RCT) was to investigate the effect of a lutein-based nutritional supplement on subjective and objective measures of visual function in healthy eyes and in eyes with age-related maculopathy (ARM) – an early form of ARMD. Supplement withdrawal effects were also investigated. A sample size of 66 healthy older (HO), healthy younger (HY), and ARM eyes were randomly allocated to receive a lutein-based supplement or no treatment for 40 weeks. The supplemented group then stopped supplementation to look at the effects of withdrawal over a further 20 weeks. The primary outcome measure was multifocal electroretinogram (mfERG) N1P1 amplitude. Secondary outcome measures were mfERG N1, P1 and N2 latency, contrast sensitivity (CS), Visual acuity (VA) and macular pigment optical density (MPOD). Sample sizes were sufficient for the RCT to have an 80% power to detect a significant clinical effect at the 5% significance level for all outcome measures when the healthy eye groups were combined, and CS, VA and mfERG in the ARM group. This RCT demonstrates significant improvements in MPOD in HY and HO supplemented eyes. When HY and HO supplemented groups were combined, MPOD improvements were maintained, and mfERG ring 2 P1 latency became shorter. On withdrawal of the supplement mfERG ring 1 N1P1 amplitude reduced in HO eyes. When HO and HY groups were combined, mfERG ring 1 and ring 2 N1P1 amplitudes were reduced. In ARM eyes, ring 3 N2 latency and ring 4 P1 latency became longer. These statistically significant changes may not be clinically significant. The finding that a lutein-based supplement increases MPOD in healthy eyes, but does not increase mfERG amplitudes contrasts with the CARMIS study and contributes to the debate on the use of nutritional supplementation in ARM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To compare the recognized defined daily dose per 100 bed-days (DDD/100 bed-days) measure with the defined daily dose per finished consultant episode (DDD/FCE) in a group of hospitals with a variety of medicines management strategies. To compare antibiotic usage using the above indicators in hospitals with and without electronic prescribing systems. Methods: Twelve hospitals were used in the study. Nine hospitals were selected and split into three cohorts (three high-scoring, three medium-scoring and three low-scoring) by their 2001 medicines management self-assessment scores (MMAS). An additional cohort of three electronic prescribing hospitals was included for comparison. MMAS were compared to antibiotic management scores (AMS) developed from a questionnaire relating specifically to control of antibiotics. FCEs and occupied bed-days were obtained from published statistics and statistical analyses of the DDD/100 bed-days and DDD/FCE were carried out using SPSS. Results: The DDD/100 bed-days varied from 81.33 to 189.37 whilst the DDD/FCE varied from 2.88 to 7.43. The two indicators showed a high degree of correlation with r = 0.74. MMAS were from 9 to 22 (possible range 0-23) and the AMS from 2 to 13 (possible range 0-22). The two scores showed a high degree of correlation with r = 0.74. No correlation was established between either indicator and either score. Conclusions: The WHO indicator for medicines utilization, DDD/100 bed-days, exhibited the same level of conformity as that exhibited from the use of the DDD/FCE indicating that the DDD/FCE is a useful additional indicator for identifying hospitals which require further study. The MMAS can be assumed to be an accurate guide to antibiotic medicines management controls. No relationship has been found between a high degree of medicines management control and the quantity of antibiotic prescribed. © The British Society for Antimicrobial Chemotherapy; 2004 all rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To assess the inter and intra observer variability of subjective grading of the retinal arterio-venous ratio (AVR) using a visual grading and to compare the subjectively derived grades to an objective method using a semi-automated computer program. Methods: Following intraocular pressure and blood pressure measurements all subjects underwent dilated fundus photography. 86 monochromatic retinal images with the optic nerve head centred (52 healthy volunteers) were obtained using a Zeiss FF450+ fundus camera. Arterio-venous ratios (AVR), central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) were calculated on three separate occasions by one single observer semi-automatically using the software VesselMap (ImedosSystems, Jena, Germany). Following the automated grading, three examiners graded the AVR visually on three separate occasions in order to assess their agreement. Results: Reproducibility of the semi-automatic parameters was excellent (ICCs: 0.97 (CRAE); 0.985 (CRVE) and 0.952 (AVR)). However, visual grading of AVR showed inter grader differences as well as discrepancies between subjectively derived and objectively calculated AVR (all p < 0.000001). Conclusion: Grader education and experience leads to inter-grader differences but more importantly, subjective grading is not capable to pick up subtle differences across healthy individuals and does not represent true AVR when compared with an objective assessment method. Technology advancements mean we no longer rely on opthalmoscopic evaluation but can capture and store fundus images with retinal cameras, enabling us to measure vessel calibre more accurately compared to visual estimation; hence it should be integrated in optometric practise for improved accuracy and reliability of clinical assessments of retinal vessel calibres. © 2014 Spanish General Council of Optometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article conceptualises and operationalizes ‘subjective entrepreneurial success’ in a manner which reflects the criteria employed by entrepreneurs, rather than those imposed by researchers. Using two studies, a first qualitative enquiry investigated success definitions using interviews with 185 German entrepreneurs; five factors emerged from their reports: firm performance, workplace relationships, personal fulfilment, community impact, and personal financial rewards. The second study developed a questionnaire, the Subjective Entrepreneurial Success–Importance Scale (SES-IS), to measure these five factors using a sample of 184 entrepreneurs. We provide evidence for the validity of the SES-IS, including establishing systematic relationships of SES-IS with objective indicators of firm success, annual income and entrepreneur satisfaction with life and financial situation. We also provide evidence for the cross-cultural invariance of SES-IS using a sample of Polish entrepreneurs. The quintessence of our studies being that subjective entrepreneurial success is a multi-factorial construct, i.e. entrepreneurs value various indicators of success with money as only one possible option.