6 resultados para Objective diagnosis
em Aston University Research Archive
Resumo:
Visual field assessment is a core component of glaucoma diagnosis and monitoring, and the Standard Automated Perimetry (SAP) test is considered up until this moment, the gold standard of visual field assessment. Although SAP is a subjective assessment and has many pitfalls, it is being constantly used in the diagnosis of visual field loss in glaucoma. Multifocal visual evoked potential (mfVEP) is a newly introduced method used for visual field assessment objectively. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard SAP visual field assessment, and others were not very informative and needed more adjustment and research work. In this study, we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. OBJECTIVES: The purpose of this study is to examine the effectiveness of a new analysis method in the Multi-Focal Visual Evoked Potential (mfVEP) when it is used for the objective assessment of the visual field in glaucoma patients, compared to the gold standard technique. METHODS: 3 groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey visual field HFA test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the Hemifield Sector Analysis HSA protocol. Analysis of the HFA was done using the standard grading system. RESULTS: Analysis of mfVEP results showed that there was a statistically significant difference between the 3 groups in the mean signal to noise ratio SNR (ANOVA p<0.001 with a 95% CI). The difference between superior and inferior hemispheres in all subjects were all statistically significant in the glaucoma patient group 11/11 sectors (t-test p<0.001), partially significant 5/11 (t-test p<0.01) and no statistical difference between most sectors in normal group (only 1/11 was significant) (t-test p<0.9). sensitivity and specificity of the HAS protocol in detecting glaucoma was 97% and 86% respectively, while for glaucoma suspect were 89% and 79%. DISCUSSION: The results showed that the new analysis protocol was able to confirm already existing field defects detected by standard HFA, was able to differentiate between the 3 study groups with a clear distinction between normal and patients with suspected glaucoma; however the distinction between normal and glaucoma patients was especially clear and significant. CONCLUSION: The new HSA protocol used in the mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patient. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.
Resumo:
CONCLUSIONS: The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PURPOSE: Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. METHODS: Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. RESULTS: Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively.
Resumo:
Objective. Our aim was to examine how diagnosis is perceived by a sample of newly diagnosed type 2 diabetes patients. Methods. A qualitative study was carried out in the Lothian region of Scotland using in-depth interviews of 40 newly diagnosed type 2 diabetes patients recruited from 16 general practices in four Local Health Care Co-operatives and three hospital clinics. Purposive selection ensured that the sample's demographic characteristics were broadly representative of newly diagnosed type 2 diabetes patients in Lothian/Scotland. Results. Clarity, timing and authority of the diagnosis delivery were highly salient for patients. Many patients perceived their GP as unwilling to deliver/confirm the diagnosis. Patients who were not referred to hospital were unclear why a referral had not taken place. Those referred perceived confirmation of diagnosis by the consultant as a central reason. Waiting for a hospital appointment could be problematic for patients. Most wanted the diagnosis confirmed before they felt confident making lifestyle changes. Input from health services during the period prior to the hospital visit was highly valued. Waiting was taken by some asymptomatic patients to indicate that they did not have the condition. Others used a lengthy period of waiting to confirm their view that they had a 'milder' or 'less serious' form of diabetes than other patients. Conclusions. Adequate input from practitioners is needed to ensure that diagnosis is fully exploited as a crucial period in which patients learn to adapt to their condition. Being explicit about the diagnosis at first contact may avoid the problem of patients feeling 'in limbo' or uncertain whether they have type 2 diabetes. Practitioners should convey to patients that post-diagnosis/initial care is a process, stages of this process should be clarified to avoid misunderstanding and services should be integrated during this interim period to best effect. © Oxford University Press 2004; all rights reserved.
Resumo:
Objective. Infective endocarditis (IE) is diagnosed by the Duke criteria, which can be inconclusive particularly when blood cultures are negative. This study investigated the application of polymerase chain reaction (PCR) to identify bacterial DNA in excised valvular tissue, and its role in establishing the diagnosis of IE. Methods. Ninety-eight patients undergoing valve replacement surgery were studied. Twenty-eight patients were confirmed as definite for endocarditis by the Duke criteria; nine were considered as possible and 61 had no known or previous microbial infection of the endocardium. A broad-range PCR technique was used to amplify prokaryotic 16S rRNA genes present within homogenised heart valve tissue. Subsequent DNA sequencing of the PCR amplicon allowed identification of the infecting microorganism. Results. PCR results demonstrated the presence of bacterial DNA in the heart valves obtained from 14 out of 20 (70%) definite IE patients with positive blood cultures preoperatively. The causative microorganism for one patient with definite culture negative endocarditis was identified by PCR. Two out of nine (22%) of the valves from possible endocarditis patients also had bacterial DNA present converting them into the definite criteria whereas in the valves of seven out of nine (78%) of these patients no bacterial DNA was detected. Conclusion. The application of PCR to the explanted valves in patients with possible or confirmed diagnosis can augment the Duke criteria thereby improving post-surgical antimicrobial therapeutic options. © 2003 The British Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
The objective of this study was to identify a set of 'essential' behaviours sufficient for diagnosis of DSM-5 Autism Spectrum Disorder (ASD). Highly discriminating, 'essential' behaviours were identified from the published DSM-5 algorithm developed for the Diagnostic Interview for Social and Communication Disorders (DISCO). Study 1 identified a reduced item set (48 items) with good predictive validity (as measured using receiver operating characteristic curves) that represented all symptom sub-domains described in the DSM-5 ASD criteria but lacked sensitivity for individuals with higher ability. An adjusted essential item set (54 items; Study 2) had good sensitivity when applied to individuals with higher ability and performance was comparable to the published full DISCO DSM-5 algorithm. Investigation at the item level revealed that the most highly discriminating items predominantly measured social-communication behaviours. This work represents a first attempt to derive a reduced set of behaviours for DSM-5 directly from an existing standardised ASD developmental history interview and has implications for the use of DSM-5 criteria for clinical and research practice. © 2014 The Authors.
Resumo:
OBJECTIVE: The discipline of clinical neuropsychiatry currently provides specialised services for a number of conditions that cross the traditional boundaries of neurology and psychiatry, including non-epileptic attack disorder. Neurophysiological investigations have an important role within neuropsychiatry services, with video-electroencephalography (EEG) telemetry being the gold standard investigation for the differential diagnosis between epileptic seizures and non-epileptic attacks. This article reviews existing evidence on best practices for neurophysiology investigations, with focus on safety measures for video-EEG telemetry. METHODS: We conducted a systematic literature review using the PubMed database in order to identify the scientific literature on the best practices when using neurophysiological investigations in patients with suspected epileptic seizures or non-epileptic attacks. RESULTS: Specific measures need to be implemented for video-EEG telemetry to be safely and effectively carried out by neuropsychiatry services. A confirmed diagnosis of non-epileptic attack disorder following video-EEG telemetry carried out within neuropsychiatry units has the inherent advantage of allowing diagnosis communication and implementation of treatment strategies in a timely fashion, potentially improving clinical outcomes and cost-effectiveness significantly. CONCLUSION: The identified recommendations set the stage for the development of standardised guidelines to enable neuropsychiatry services to implement streamlined and evidence-based care pathways.