Aim: The aim of this study was to evaluate the practicality and accuracy of tonometers used in routine clinical practice for established keratoconus (KC). Methods: This was a prospective study of 118 normal and 76 keratoconic eyes where intraocular pressure (IOP) was measured in random order using the Goldman applanation tonometer (GAT), Pascal dynamic contour tonometer (DCT), Reichert ocular response analyser (ORA) and TonoPen XL tonometer. Corneal hysteresis (CH) and corneal resistance factor (CRF), as calculated by the ORA, were recorded. Central corneal thickness (CCT) was measured using an ultrasound pachymeter. Results: The difference in IOP values between instruments was highly significant in both study groups (p<0.001). All other IOP measures were significantly higher than those for GAT, except for the Goldmann-correlated IOP (average of the two applanation pressure points) (IOPg) as measured by ORA in the control group and the CH-corrected IOP (corneal-compensated IOP value) (IOPcc) measures in the KC group. CCT, CH and CRF were significantly less in the KC group (p<0.001). Apart from the DCT, all techniques tended to measure IOP higher in eyes with thicker corneas. Conclusion: The DCT and the ORA are currently the most appropriate tonometers to use in KC for the measurement of IOPcc. Corneal factors such as CH and CRT may be of more importance than CCT in causing inaccuracies in applanation tonometry techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abnormally enlarged neurons (AEN) occur in many neurodegenerative diseases. To define AEN more objectively, the frequency distribution of the ratio of greatest cell diameter(CD) to greatest nuclear diameter (ND) was studied in populations of cortical neurons in tissue sections of seven cognitively normal brains. The frequency distribution of CD/ND deviated from a normal distribution in 15 out of 18 populations of neurons studied and hence, the 95th percentile (95P) was used to define a limit of the CD/ND ratio excluding the5% most extreme observations. The 95P of the CD/ ND ratio varied from 2.0 to 3.0 in different cases and regions and a value of 95P = 3.0 was chosen to define the limit for normalneurons under non-pathological conditions. Based on the 95P = 3.0 criterion, the proportion of AEN with a CD/ND ≥ 3 varied from 2.6% in Alzheimer's disease (AD) to 20.3% in Pick's disease (PiD). The data suggest: (1) that a CL/ND ≥ 3.0 may be a useful morphological criterion for defining AEN, and (2) AEN were most numerous in PiD and corticobasal degeneration (CBD) and least abundant in AD and in dementia with Lewy bodies (DLB). © 2013 Dustri-Verlag Dr. K. Feistle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine by wavefront analysis the difference between eyes considered normal, eyes diagnosed with keratoconus, and eyes that have undergone penetrating keratoplasty METHODS: The Nidek OPD-Scan wavefront aberrometer was used to measure ocular aberrations out to the sixth Zernike order. One hundred and thirty eyes that were free of ocular pathology, 41 eyes diagnosed with keratoconus, and 8 eyes that had undergone penetrating keratoplasty were compared for differences in root mean square value. Three and five millimeter root mean square values of the refractive power aberrometry maps of the three classes of eyes were compared. Radially symmetric and irregular higher order aberration values were compared for differences in magnitude. RESULTS: Root mean square values were lower in eyes free of ocular pathology compared to eyes with keratoconus and eyes that had undergone penetrating keratoplasty. The aberrations were larger with the 5-mm pupil. Coma and spherical aberration values were lower in normal eyes. CONCLUSION: Wavefront aberrometry of normal, pathological, and eyes after surgery may help to explain the visual distortions encountered by patients. The ability to measure highly aberrated eyes allows an objective assessment of the optical consequences of ocular pathology and surgery. The Nidek OPD-Scan can be used in areas other than refractive surgery.