17 resultados para NSM FRP CFRP continuous quality control monitoring bond EMM-ARM

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of 8-oxo-7,8-dihydro-2'-deoxyguanosine is an increasingly popular marker of in vivo oxidative damage to DNA. A random-sequence 21-mer oligonucleotide 5'-TCA GXC GTA CGT GAT CTC AGT-3' in which X was 8-oxo-guanine (8-oxo-G) was purified and accurate determination of the oxidised base was confirmed by a 32P-end labelling strategy. The lyophilised material was analysed for its absolute content of 8-oxo-dG by several major laboratories in Europe and one in Japan. Most laboratories using HPLC-ECD underestimated, while GC-MS-SIM overestimated the level of the lesion. HPLC-ECD measured the target value with greatest accuracy. The results also suggest that none of the procedures can accurately quantitate levels of 1 in 10(6) 8-oxo-(d)G in DNA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives - Powdered and granulated particulate materials make up most of the ingredients of pharmaceuticals and are often at risk of undergoing unwanted agglomeration, or caking, during transport or storage. This is particularly acute when bulk powders are exposed to extreme swings in temperature and relative humidity, which is now common as drugs are produced and administered in increasingly hostile climates and are stored for longer periods of time prior to use. This study explores the possibility of using a uniaxial unconfined compression test to compare the strength of caked agglomerates exposed to different temperatures and relative humidities. This is part of a longer-term study to construct a protocol to predict the caking tendency of a new bulk material from individual particle properties. The main challenge is to develop techniques that provide repeatable results yet are presented simply enough to be useful to a wide range of industries. Methods - Powdered sucrose, a major pharmaceutical ingredient, was poured into a split die and exposed to high and low relative humidity cycles at room temperature. The typical ranges were 20–30% for the lower value and 70–80% for the higher value. The outer die casing was then removed and the resultant agglomerate was subjected to an unconfined compression test using a plunger fitted to a Zwick compression tester. The force against displacement was logged so that the dynamics of failure as well as the failure load of the sample could be recorded. The experimental matrix included varying the number of cycles, the amount between the maximum and minimum relative humidity, the height and diameters of the samples, the number of cycles and the particle size. Results - Trends showed that the tensile strength of the agglomerates increased with the number of cycles and also with the more extreme swings in relative humidity. This agrees with previous work on alternative methods of measuring the tensile strength of sugar agglomerates formed from humidity cycling (Leaper et al 2003). Conclusions - The results show that at the very least the uniaxial tester is a good comparative tester to examine the caking tendency of powdered materials, with a simple arrangement and operation that are compatible with the requirements of industry. However, further work is required to continue to optimize the height/ diameter ratio during tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a framework for considering quality control of volunteered geographic information (VGI). Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this paper is to present the application of logical framework analysis (LFA) for implementing continuous quality improvement (CQI) across multiple settings in a tertiary care hospital. Design/methodology/approach: This study adopts a multiple case study approach. LFA is implemented within three diverse settings, namely, intensive care unit, surgical ward, and acute in-patient psychiatric ward. First, problem trees are developed in order to determine the root causes of quality issues, specific to the three settings. Second, objective trees are formed suggesting solutions to the quality issues. Third, project plan template using logical framework (LOGFRAME) is created for each setting. Findings: This study shows substantial improvement in quality across the three settings. LFA proved to be effective to analyse quality issues and suggest improvement measures objectively. Research limitations/implications: This paper applies LFA in specific, albeit, diverse settings in one hospital. For validation purposes, it would be ideal to analyse in other settings within the same hospital, as well as in several hospitals. It also adopts a bottom-up approach when this can be triangulated with other sources of data. Practical implications: LFA enables top management to obtain an integrated view of performance. It also provides a basis for further quantitative research on quality management through the identification of key performance indicators and facilitates the development of a business case for improvement. Originality/value: LFA is a novel approach for the implementation of CQI programs. Although LFA has been used extensively for project development to source funds from development banks, its application in quality improvement within healthcare projects is scant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to survive in the increasingly customer-oriented marketplace, continuous quality improvement marks the fastest growing quality organization’s success. In recent years, attention has been focused on intelligent systems which have shown great promise in supporting quality control. However, only a small number of the currently used systems are reported to be operating effectively because they are designed to maintain a quality level within the specified process, rather than to focus on cooperation within the production workflow. This paper proposes an intelligent system with a newly designed algorithm and the universal process data exchange standard to overcome the challenges of demanding customers who seek high-quality and low-cost products. The intelligent quality management system is equipped with the ‘‘distributed process mining” feature to provide all levels of employees with the ability to understand the relationships between processes, especially when any aspect of the process is going to degrade or fail. An example of generalized fuzzy association rules are applied in manufacturing sector to demonstrate how the proposed iterative process mining algorithm finds the relationships between distributed process parameters and the presence of quality problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The automatic interpolation of environmental monitoring network data such as air quality or radiation levels in real-time setting poses a number of practical and theoretical questions. Among the problems found are (i) dealing and communicating uncertainty of predictions, (ii) automatic (hyper)parameter estimation, (iii) monitoring network heterogeneity, (iv) dealing with outlying extremes, and (v) quality control. In this paper we discuss these issues, in light of the spatial interpolation comparison exercise held in 2004.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to develop a comprehensive framework for improving intensive care unit performance. Design/methodology/approach – The study introduces a quality management framework by combining cause and effect diagram and logical framework. An intensive care unit was identified for the study on the basis of its performance. The reasons for not achieving the desired performance were identified using a cause and effect diagram with the stakeholder involvement. A logical framework was developed using information from the cause and effect diagram and a detailed project plan was developed. The improvement projects were implemented and evaluated. Findings – Stakeholders identified various intensive care unit issues. Managerial performance, organizational processes and insufficient staff were considered major issues. A logical framework was developed to plan an improvement project to resolve issues raised by clinicians and patients. Improved infrastructure, state-of-the-art equipment, well maintained facilities, IT-based communication, motivated doctors, nurses and support staff, improved patient care and improved drug availability were considered the main project outputs for improving performance. The proposed framework is currently being used as a continuous quality improvement tool, providing a planning, implementing, monitoring and evaluating framework for the quality improvement measures on a sustainable basis. Practical implications – The combined cause and effect diagram and logical framework analysis is a novel and effective approach to improving intensive care performance. Similar approaches could be adopted in any intensive care unit. Originality/value – The paper focuses on a uniform model that can be applied to most intensive care units.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Innovation is part and parcel of any service in today's environment, so as to remain competitive. Quality improvement in healthcare services is a complex, multi-dimensional task. This study proposes innovation management in healthcare services using a logical framework. A problem tree and an objective tree are developed to identify and mitigate issues and concerns. A logical framework is formulated to develop a plan for implementation and monitoring strategies, potentially creating an environment for continuous quality improvement in a specific unit. We recommend logical framework as a valuable model for innovation management in healthcare services. Copyright © 2006 Inderscience Enterprises Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Thesis reports on the principles and usefulness of Performance Rating as developed by the writer over a number of years. In Part one a brief analysis is made of the Quality scene and its development up to the present. The need is exposed for Performance Rating as a tool for all areas of management*. At the same time a system of Quality Control is described which the writer has further developed under the title of 'Operator Control'. This system is based on the integration of all Quality control functions with the creative functions required for Quality achievement. The discussions are mainly focussed on the general philosophy of Quality, its creation and control and that part of Operator Control which affects Performance Rating. Whereas it is shown that the combination of Operator Control and Performance Rating is both economically and technically advantageous, Performance Rating can also usefully be applied under inspection control conditions. Part two describes the principles of Area Performance Rating. *The need for, and the advantages of, Performance Rating are particularly demonstrated in Case study No.1. From this a summation expression is derived which gives the key for grouping of areas with similar Performance Rating (P). A model is devised on which the theory is demonstrated. Relevant case studies, carried out in practice in factories are quoted in Part two, Chapter 4, one written by the Quality manager of that particular factory. Particular stress is laid in the final conclusions on management's function in the Quality field and how greatly this function is eased and improved through the introduction of Area Performance Rating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Britain's sea and flood defences are becoming increasingly aged and as a consequence, more fragile and vulnerable. As the government's philosophy on resources shifts against the use of prime quarried and dredged geo-materials, the need to find alternative bulk materials to bolster Britain's prone defences becomes more pressing. One conceivable source for such a material is colliery waste or minestone. Although a plethora of erosion-abrasion studies have been carried out on soils and soil-cements, very little research has been undertaken to determine the resistance of minestone and its cement stabilized form to the effects of water erosion. The thesis reviews the current extent to which soil-cements, minestone and cement stabilized minestone (CSM) have been employed for hydraulic construction projects. A synopsis is also given on the effects of immersion on shales, mudstones and minestone, especially with regard to the phenomena of slaking. A laboratory study was undertaken featuring a selection of minestones from several British coalfields. The stability of minestone and CSM in sea water and distilled water was assessed using slaking tests and immersion monitoring and the bearing on the use of these materials for hydraulic construction is discussed. Following a review of current erosion apparatus, the erosion/abrasion test and rotating cylinder device were chosen and employed to assess the erosion resistance of minestone and CSM. Comparison was made with a sand mix designed to represent a dredged sand, the more traditional, bulk hydraulic construction material. The results of the erosion study suggest that both minestone and CSM were more resistant to erosion and abrasion than equivalently treated sand mixes. The greater resistance of minestone to the agents of erosion and abrasion is attributed to several factors including the size of the particles, a greater degree of cement bonding and the ability of the minestone aggregate to absorb, rather than transmit shock waves produced by impacting abrasive particles. Although minestone is shown to be highly unstable when subjected to cyclic changes in its moisture content, the study suggests that even in an intertidal regime where cyclic immersion does takes place, minestone will retain sufficient moisture within its fabric to prevent slaking from taking place. The slaking study reveals a close relationship between slaking susceptibility and total pore surface area as revealed by porosimetry. The immersion study shows that although the fabric of CSM is rapidly attacked in sea water, a high degree of the disruption is associated with the edges and corners of samples (ie. free surface) while the integrity of the internal fabric remains relatively intact. CSM samples were shown to be resilient when subjected to immersion in distilled water. An overall assessment of minestone and CSM would suggest that with the implementation of judicious selection and appropriate quality control they could be used as alternative materials for flood and sea defences. It is believed, that even in the harsh regime of a marine environment, CSM could be employed for temporary and sacrificial schemes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previously, specifications for mechanical properties of casting alloys were based on separately cast test bars. This practice provided consistently reproducible results; thus, any change in conditions was reflected in changes in the mechanical properties of the test coupons. These test specimens, however, did not necessarily reflect the actual mechanical properties of the castings they were supposed to represent'. Factors such as section thickness and casting configuration affect the solidification rate and soundness of the casting thereby raising or lowering its mechanical properties in comparison with separately cast test specimens. In the work now reported, casting shapes were developed to investigate the variations of section thickness, chemical analysis and heat treatment on the mechanical properties of a high strength Aluminium alloy under varying chilling conditions. In addition, an insight was sought into the behaviour of chills under more practical conditions. Finally, it was demonstrated that additional information could be derived from the radiographs which form an essential part of the quality control of premium quality castings. As a result of the work, it is now possible to select analysis and chilling conditions to optimize the as cast and the heat treated mechanical properties of Aluminum 7% Silicon 0.3% Magnesium alloy.