5 resultados para Monk seals.

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical seals are used extensively to seal machinery such as pumps, mixers and agitators in the oil, petrochemical and chemical industries. The performance of such machinery is critically dependent on these devices. Seal failures may result in the escape of dangerous chemicals, possibly causing injury or loss of life. Seal performance is limited by the choice of face materials available. These range from cast iron and stellited stainless steel to cemented and silicon carbides. The main factors that affect seal performance are the wear and corrosion of seal faces. This research investigated the feasibility of applying surface coating/treatments to seal materials, in order to provide improved seal performance. Various surface coating/treatment methods were considered; these included electroless nickel plating, ion plating, plasma nitriding, thermal spraying and high temperature diffusion processes. The best wear resistance, as evaluated by the Pin-on-Disc wear test method, was conferred by the sprayed tungsten carbide/nickel/tungsten-chromium carbide deposit, produced by the high energy plasma spraying (Jet-Kote) process. In general, no correlation was found between hardness and wear resistance or surface finish and friction. This is due primarily to the complexity of the wear and frictional oxidation, plastic deformation, ploughing, fracture and delamination. Corrosion resistance was evaluated by Tafel extrapolation, linear polarisation and anodic potentiodynamic polarisation techniques. The best corrosion performance was exhibited by an electroless nickel/titanium nitride duplex coating due to the passivity of the titanium nitride layer in the acidified salt solution. The surface coating/treatments were ranked using a systematic method, which also considered other properties such as adhesion, internal stress and resistance to thermal cracking. The sealing behaviour of surface coated/treated seals was investigated on an industrial seal testing rig. The best sealing performances were exhibited by the Jet-Kote and electroless nickel silicon carbide composite coated seals. The failure of the electroless nickel and electroless nickel/titanium nitride duplex coated seals was due to inadequate adhesion of the deposits to the substrate. Abrasion of the seal faces was the principal wear mechanism. For operation in an environment similar to the experimental system employed (acidified salt solution) the Jet-Kote deposit appears to be the best compromise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis covers both experimental and computer investigations into the dynamic behaviour of mechanical seals. The literature survey shows no investigations on the effect of vibration on mechanical seals of the type common in the various process industries. Typical seal designs are discussed. A form of Reynolds' equation has been developed that permits the calculation of stiffnesses and damping coefficients for the fluid film. The dynamics of the mechanical seal floating ring have been investigated using approximate formulae, and it has been shown that the floating ring will behave as a rigid body. Some elements, such as the radial damping due to the fluid film, are small and may be neglected. The equations of motion of the floating ring have been developed utilising the significant elements, and a solution technique described. The stiffness and damping coefficients of nitrile rubber o-rings have been obtained. These show a wide variation, with a constant stiffness up to 60 Hz. The importance of the effect of temperature on the properties is discussed. An unsuccessful test rig is described in the appendices. The dynamic behaviour of a mechanical seal has been investigated experimentally, including the effect of changes of speed, sealed pressure and seal geometry. The results, as expected, show that high vibration levels result in both high leakage and seal temperatures. Computer programs have been developed to solve Reynolds' Equation and the equations of motion. Two solution techniques for this latter program were developed, the unsuccesful technique is described in the appendices. Some stability problems were encountered, but despite these the solution shows good agreement with some of the experimental conditions. Possible reasons for the discrepancies are discussed. Various suggestions for future work in this field are given. These include the combining of the programs and more extensive experimental and computer modelling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential for microbial contamination associated with a recently developed needleless closed luer access device (CLAD) (Q-Syte™ Becton Dickinson, Sandy, UT, USA) was evaluated in vitro. Compression seals of 50 multiply activated Q-Syte devices were inoculated with Staphylococcus epidermidis NCTC 9865 in 25% (v/v) human blood and then disinfected with 70% (v/v) isopropyl alcohol followed by flushing with 0.9% (w/v) sterile saline. Forty-eight of 50 (96%) saline flushes passed through devices that had been activated up to a maximum of 70 times remained sterile. A further 25 Q-Syte CLADs that had undergone multiple activations were challenged with prefilled 0.9% (w/v) sterile saline syringes, the external luer tips of which had been inoculated with S. epidermidis NCTC 9865 prior to accessing the devices. None of the devices that had been accessed up to 70 times allowed passage of micro-organisms, despite challenge micro-organisms being detected on both the syringe tip after activation and the compression seals before decontamination. These findings suggest that the Q-Syte CLAD may be activated up to 70 times with no increased risk of microbial contamination within the fluid pathway. The device may also offer protection from the external surface of syringe tips contaminated with micro-organisms. © 2005 Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis describes the procedure and results from four years research undertaken through the IHD (Interdisciplinary Higher Degrees) Scheme at Aston University in Birmingham, sponsored by the SERC (Science and Engineering Research Council) and Monk Dunstone Associates, Chartered Quantity Surveyors. A stochastic networking technique VERT (Venture Evaluation and Review Technique) was used to model the pre-tender costs of public health, heating ventilating, air-conditioning, fire protection, lifts and electrical installations within office developments. The model enabled the quantity surveyor to analyse, manipulate and explore complex scenarios which previously had defied ready mathematical analysis. The process involved the examination of historical material costs, labour factors and design performance data. Components and installation types were defined and formatted. Data was updated and adjusted using mechanical and electrical pre-tender cost indices and location, selection of contractor, contract sum, height and site condition factors. Ranges of cost, time and performance data were represented by probability density functions and defined by constant, uniform, normal and beta distributions. These variables and a network of the interrelationships between services components provided the framework for analysis. The VERT program, in this particular study, relied upon Monte Carlo simulation to model the uncertainties associated with pre-tender estimates of all possible installations. The computer generated output in the form of relative and cumulative frequency distributions of current element and total services costs, critical path analyses and details of statistical parameters. From this data alternative design solutions were compared, the degree of risk associated with estimates was determined, heuristics were tested and redeveloped, and cost significant items were isolated for closer examination. The resultant models successfully combined cost, time and performance factors and provided the quantity surveyor with an appreciation of the cost ranges associated with the various engineering services design options.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.