9 resultados para Monitoring tool
em Aston University Research Archive
Resumo:
This paper critically evaluates the paradigm, theory, and methodology that dominate research on related party transactions (RPTs). RPTs have been debated in the literature whether they are a facet of conflict of interest between major and minor shareholders or they are normal efficient transactions that help the firms to achieve asset utilization. Literature has been widely interested in studying the association between corporate governance and RPTs especially that according to the agency theory it is assumed that corporate governance as a monitoring tool should impede the negative consequences of RPTs and ensure they are conducted to achieve better asset utilization.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
With an ageing population, the number of age-related macular disease (ARMD) cases will inevitably rise. This gives greater impetus for the need to identify the disease earlier and assess treatments to slow disease progression. Differing electroretinogram (ERG) modalities have been reviewed in relation to the objective assessment of retinal function in ARMD and for monitoring the effectiveness of clinical interventions. Conflicting results have been found with regard to the efficacy of ERG findings in the investigation of ARMD in previous years. The newer multifocal ERG paradigm provides spatial topographical information about retinal function in ARMD. It has shown promising results in monitoring effectiveness of clinical interventions and studies are continuing in this area. Better knowledge of retinal function in ARMD may lead to enhanced treatments at each phase of the disease.
Resumo:
Deep hole drilling is one of the most complicated metal cutting processes and one of the most difficult to perform on CNC machine-tools or machining centres under conditions of limited manpower or unmanned operation. This research work investigates aspects of the deep hole drilling process with small diameter twist drills and presents a prototype system for real time process monitoring and adaptive control; two main research objectives are fulfilled in particular : First objective is the experimental investigation of the mechanics of the deep hole drilling process, using twist drills without internal coolant supply, in the range of diarneters Ø 2.4 to Ø4.5 mm and working length up to 40 diameters. The definition of the problems associated with the low strength of these tools and the study of mechanisms of catastrophic failure which manifest themselves well before and along with the classic mechanism of tool wear. The relationships between drilling thrust and torque with the depth of penetration and the various machining conditions are also investigated and the experimental evidence suggests that the process is inherently unstable at depths beyond a few diameters. Second objective is the design and implementation of a system for intelligent CNC deep hole drilling, the main task of which is to ensure integrity of the process and the safety of the tool and the workpiece. This task is achieved by means of interfacing the CNC system of the machine tool to an external computer which performs the following functions: On-line monitoring of the drilling thrust and torque, adaptive control of feed rate, spindle speed and tool penetration (Z-axis), indirect monitoring of tool wear by pattern recognition of variations of the drilling thrust with cumulative cutting time and drilled depth, operation as a data base for tools and workpieces and finally issuing of alarms and diagnostic messages.
Resumo:
Ambulatory EEG recording enables patients with epilepsy and related disorders to be monitored in an unrestricted environment for prolonged periods. Attacks can therefore be recorded and EEG changes at the time can aid diagnosis. The relevant Iiterature is reviewed and a study made of' 250 clinical investigations. A study was also made of the artefacts,encountered during ambulatory recording. Three quarters of referrals were for distinguishing between epileptic and non-epileptic attacks. Over 60% of patients showed no abnormality during attacks. In comparison with the basic EEG the ambulatory EEG provided about ten times as much information. A preliminary follow-up study showed that results, of ambulatory monitoring agreed with the final diagnosis in 8 of 12 patients studied. Of 10 patients referred, for monitoring the occurrence of absence seizures, 8 showed abnormality during the baslcJ EEG .and 10 during the ambulatory EEG. Other patients. were referred: for sleep recording and to clarify the seizure type. An investigation into once daily (OD) versus twice daily administration of sodium valproate in patients with absence seizures showed that an OD regime was equally as effective as a BD regime. Circadian variations in spike and wave activity in patients on and off treatment were also examined. There was significant agreement between subjects on the time of occurrence of abnormality during sleep only, This pattern was not ,affected with treatment nor was there any difference in the daily pattern of occurrence of abnormality between the two regimes. Overall findings suggested that ambulatory monitoring was a valuable tool in the diagnosis and treatment of epilepsy which with careful planning and patient selection could be used in any EEG department and would benefit a:wide range of patients.
Resumo:
Background: Remote, non-invasive and objective tests that can be used to support expert diagnosis for Parkinson's disease (PD) are lacking. Methods: Participants underwent baseline in-clinic assessments, including the Unified Parkinson's Disease Rating Scale (UPDRS), and were provided smartphones with an Android operating system that contained a smartphone application that assessed voice, posture, gait, finger tapping, and response time. Participants then took the smart phones home to perform the five tasks four times a day for a month. Once a week participants had a remote (telemedicine) visit with a Parkinson disease specialist in which a modified (excluding assessments of rigidity and balance) UPDRS performed. Using statistical analyses of the five tasks recorded using the smartphone from 10 individuals with PD and 10 controls, we sought to: (1) discriminate whether the participant had PD and (2) predict the modified motor portion of the UPDRS. Results: Twenty participants performed an average of 2.7 tests per day (68.9% adherence) for the study duration (average of 34.4 days) in a home and community setting. The analyses of the five tasks differed between those with Parkinson disease and those without. In discriminating participants with PD from controls, the mean sensitivity was 96.2% (SD 2%) and mean specificity was 96.9% (SD 1.9%). The mean error in predicting the modified motor component of the UPDRS (range 11-34) was 1.26 UPDRS points (SD 0.16). Conclusion: Measuring PD symptoms via a smartphone is feasible and has potential value as a diagnostic support tool.
Resumo:
Liquid-level sensing technologies have attracted great prominence, because such measurements are essential to industrial applications, such as fuel storage, flood warning and in the biochemical industry. Traditional liquid level sensors are based on electromechanical techniques; however they suffer from intrinsic safety concerns in explosive environments. In recent years, given that optical fiber sensors have lots of well-established advantages such as high accuracy, costeffectiveness, compact size, and ease of multiplexing, several optical fiber liquid level sensors have been investigated which are based on different operating principles such as side-polishing the cladding and a portion of core, using a spiral side-emitting optical fiber or using silica fiber gratings. The present work proposes a novel and highly sensitive liquid level sensor making use of polymer optical fiber Bragg gratings (POFBGs). The key elements of the system are a set of POFBGs embedded in silicone rubber diaphragms. This is a new development building on the idea of determining liquid level by measuring the pressure at the bottom of a liquid container, however it has a number of critical advantages. The system features several FBG-based pressure sensors as described above placed at different depths. Any sensor above the surface of the liquid will read the same ambient pressure. Sensors below the surface of the liquid will read pressures that increase linearly with depth. The position of the liquid surface can therefore be approximately identified as lying between the first sensor to read an above-ambient pressure and the next higher sensor. This level of precision would not in general be sufficient for most liquid level monitoring applications; however a much more precise determination of liquid level can be made by linear regression to the pressure readings from the sub-surface sensors. There are numerous advantages to this multi-sensor approach. First, the use of linear regression using multiple sensors is inherently more accurate than using a single pressure reading to estimate depth. Second, common mode temperature induced wavelength shifts in the individual sensors are automatically compensated. Thirdly, temperature induced changes in the sensor pressure sensitivity are also compensated. Fourthly, the approach provides the possibility to detect and compensate for malfunctioning sensors. Finally, the system is immune to changes in the density of the monitored fluid and even to changes in the effective force of gravity, as might be obtained in an aerospace application. The performance of an individual sensor was characterized and displays a sensitivity (54 pm/cm), enhanced by more than a factor of 2 when compared to a sensor head configuration based on a silica FBG published in the literature, resulting from the much lower elastic modulus of POF. Furthermore, the temperature/humidity behavior and measurement resolution were also studied in detail. The proposed configuration also displays a highly linear response, high resolution and good repeatability. The results suggest the new configuration can be a useful tool in many different applications, such as aircraft fuel monitoring, and biochemical and environmental sensing, where accuracy and stability are fundamental. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Resumo:
Background: To examine the views and current practice of SMBG among Black Caribbean and South Asian individuals with non-insulin treated Type 2 diabetes mellitus. Methods: Twelve participants completed semi-structured interviews that were guided by the Health Belief Model and analyzed using thematic network analysis. Results: The frequency of monitoring among participants varied from several times a day to once per week. Most participants expressed similar experiences regarding their views and practices of SMBG. Minor differences across gender and culture were observed. All participants understood the benefits, but not all viewed SMBG as beneficial to their personal diabetes management. SMBG can facilitate a better understanding and maintenance of self-care behaviours. However, it can trigger both positive and negative emotional responses, such as a sense of disappointment when high readings are not anticipated, resulting in emotional distress. Health care professionals play a key role in the way SMBG is perceived and used by patients. Conclusion: While the majority of participants value SMBG as a self-management tool, barriers exist that impede its practice, particularly its cost. How individuals cope with these barriers is integral to understanding why some patients adopt SMBG more than others. © 2013 Gucciardi et al.; licensee BioMed Central Ltd.
Resumo:
Monitoring is essential for conservation of sites, but capacity to undertake it in the field is often limited. Data collected by remote sensing has been identified as a partial solution to this problem, and is becoming a feasible option, since increasing quantities of satellite data in particular are becoming available to conservationists. When suitably classified, satellite imagery can be used to delineate land cover types such as forest, and to identify any changes over time. However, the conservation community lacks (a) a simple tool appropriate to the needs for monitoring change in all types of land cover (e.g. not just forest), and (b) an easily accessible information system which allows for simple land cover change analysis and data sharing to reduce duplication of effort. To meet these needs, we developed a web-based information system which allows users to assess land cover dynamics in and around protected areas (or other sites of conservation importance) from multi-temporal medium resolution satellite imagery. The system is based around an open access toolbox that pre-processes and classifies Landsat-type imagery, and then allows users to interactively verify the classification. These data are then open for others to utilize through the online information system. We first explain imagery processing and data accessibility features, and then demonstrate the toolbox and the value of user verification using a case study on Nakuru National Park, Kenya. Monitoring and detection of disturbances can support implementation of effective protection, assist the work of park managers and conservation scientists, and thus contribute to conservation planning, priority assessment and potentially to meeting monitoring needs for Aichi target 11.