17 resultados para Monitoring methods
em Aston University Research Archive
Resumo:
In this study some common types of Rolling Bearing vibrations are analysed in depth both theoretically and experimentally. The study is restricted to vibrations in the radial direction of bearings having pure radial load and a positive radial clearance. The general vibrational behaviour of such bearings has been investigated with respect to the effects of varying compliance, manufacturing tolerances and the interaction between the bearing and the machine structure into which it is fitted. The equations of motion for a rotor supported by a bearing in which the stiffness varies with cage position has been set up and examples of solutions,obtained by digital simulation. is given. A method to calculate amplitudes and frequencies of vibration components due to out of roundness of the inner ring and varying roller diameters has been developed. The results from these investigations have been combined with a theory for bearing/machine frame interaction using mechanical impedance technique, thereby facilitating prediction of the vibrational behaviour of the whole set up. Finally. the effects of bearing fatigue and wear have been studied with particular emphasis on the use of vibration analysis for condition monitoring purposes. A number of monitoring methods have been tried and their effectiveness discussed. The experimental investigation was carried out using two purpose built rigs. For the purpose of analysis of the experimental measurements a digital mini computer was adapted for signal processing and a suite of programs was written. The program package performs several of the commonly used signal analysis processes and :include all necessary input and output functions.
Resumo:
Objective: To assess and explain deviations from recommended practice in National Institute for Clinical Excellence (NICE) guidelines in relation to fetal heart monitoring. Design: Qualitative study. Setting: Large teaching hospital in the UK. Sample: Sixty-six hours of observation of 25 labours and interviews with 20 midwives of varying grades. Methods: Structured observations of labour and semistructured interviews with midwives. Interviews were undertaken using a prompt guide, audiotaped, and transcribed verbatim. Analysis was based on the constant comparative method, assisted by QSR N5 software. Main outcome measures: Deviations from recommended practice in relation to fetal monitoring and insights into why these occur. Results: All babies involved in the study were safely delivered, but 243 deviations from recommended practice in relation to NICE guidelines on fetal monitoring were identified, with the majority (80%) of these occurring in relation to documentation. Other deviations from recommended practice included indications for use of electronic fetal heart monitoring and conduct of fetal heart monitoring. There is evidence of difficulties with availability and maintenance of equipment, and some deficits in staff knowledge and skill. Differing orientations towards fetal monitoring were reported by midwives, which were likely to have impacts on practice. The initiation, management, and interpretation of fetal heart monitoring is complex and distributed across time, space, and professional boundaries, and practices in relation to fetal heart monitoring need to be understood within an organisational and social context. Conclusion: Some deviations from best practice guidelines may be rectified through straightforward interventions including improved systems for managing equipment and training. Other deviations from recommended practice need to be understood as the outcomes of complex processes that are likely to defy easy resolution. © RCOG 2006.
Resumo:
Automatically generating maps of a measured variable of interest can be problematic. In this work we focus on the monitoring network context where observations are collected and reported by a network of sensors, and are then transformed into interpolated maps for use in decision making. Using traditional geostatistical methods, estimating the covariance structure of data collected in an emergency situation can be difficult. Variogram determination, whether by method-of-moment estimators or by maximum likelihood, is very sensitive to extreme values. Even when a monitoring network is in a routine mode of operation, sensors can sporadically malfunction and report extreme values. If this extreme data destabilises the model, causing the covariance structure of the observed data to be incorrectly estimated, the generated maps will be of little value, and the uncertainty estimates in particular will be misleading. Marchant and Lark [2007] propose a REML estimator for the covariance, which is shown to work on small data sets with a manual selection of the damping parameter in the robust likelihood. We show how this can be extended to allow treatment of large data sets together with an automated approach to all parameter estimation. The projected process kriging framework of Ingram et al. [2007] is extended to allow the use of robust likelihood functions, including the two component Gaussian and the Huber function. We show how our algorithm is further refined to reduce the computational complexity while at the same time minimising any loss of information. To show the benefits of this method, we use data collected from radiation monitoring networks across Europe. We compare our results to those obtained from traditional kriging methodologies and include comparisons with Box-Cox transformations of the data. We discuss the issue of whether to treat or ignore extreme values, making the distinction between the robust methods which ignore outliers and transformation methods which treat them as part of the (transformed) process. Using a case study, based on an extreme radiological events over a large area, we show how radiation data collected from monitoring networks can be analysed automatically and then used to generate reliable maps to inform decision making. We show the limitations of the methods and discuss potential extensions to remedy these.
Resumo:
Aims To date, there is no convincing evidence that non-insulin treated patients who undertake self-blood glucose monitoring (SBGM) have better glycaemic control than those who test their urine. This has led to a recommendation that non-insulin dependent patients undertake urine testing, which is the cheaper option. This recommendation does not take account of patients' experiences and views. This study explores the respective merits of urine testing and SBGM from the perspectives of newly diagnosed patients with Type 2 diabetes. Methods Qualitative study using repeat in-depth interviews with 40 patients. Patients were interviewed three times at 6-monthly intervals over 1 year. Patients were recruited from hospital clinics and general practices in Lothian, Scotland. The study was informed by grounded theory, which involves concurrent data collection and analysis. Results Patients reported strongly negative views of urine testing, particularly when they compared it with SBGM. Patients perceived urine testing as less convenient, less hygienic and less accurate than SBGM. Most patients assumed that blood glucose meters were given to those with a more advanced or serious form of diabetes. This could have implications for how they thought about their own disease. Patients often interpreted negative urine results as indicating that they could not have diabetes. Conclusions Professionals should be aware of the meanings and understandings patients attach to the receipt and use of different types of self-monitoring equipment. Guidelines that promote the use of consistent criteria for equipment allocation are required. The manner in which negative urine results are conveyed needs to be reconsidered.
Resumo:
Aerial photography was used to determine the land use in a test area of the Nigerian savanna in 1950 and 1972. Changes in land use were determined and correlated with accessibility, appropriate low technology methods being used to make it easy to extend the investigation to other areas without incurring great expense. A test area of 750 sq km was chosen located in Kaduna State of Nigeria. The geography of the area is summarised together with the local knowledge which is essential for accurate photo interpretation. A land use classification was devised and tested for use with medium scale aerial photography of the savanna. The two sets of aerial photography at 1:25 000 scale were sampled using systematic dot grids. A dot density of 8 1/2 dots per sq km was calculated to give an acceptable estimate of land use. Problems of interpretation included gradation between categories, sample position uncertainty and personal bias. The results showed that in 22 years the amount of cultivated land in the test area had doubled while there had been a corresponding decrease in the amount of uncultivated land particularly woodland. The intensity of land use had generally increased. The distribution of land use changes was analysed and correlated with accessibility. Highly significant correlations were found for 1972 which had not existed in 1950. Changes in land use could also be correlated with accessibility. It was concluded that in the 22 year test period there had been intensification of land use, movement of human activity towards the main road, and a decrease in natural vegetation particularly close to the road. The classification of land use and the dot grid method of survey were shown to be applicable to a savanna test area.
Resumo:
This thesis set out to develop an objective analysis programme that correlates with subjective grades but has improved sensitivity and reliability in its measures so that the possibility of early detection and reliable monitoring of changes in anterior ocular surfaces (bulbar hyperaemia, palpebral redness, palpebral roughness and corneal straining) could be increased. The sensitivity of the program was 20x greater than subjective grading by optometrists. The reliability was found to be optimal (r=1.0) with subjective grading up to 144x more variable (r=0.08). Objective measures were used to create formulae for an overall ‘objective-grade’ (per surface) equivalent to those displayed by the CCLRU or Efron scales. The correlation between the formulated objective verses subjective grades was high, with adjusted r2 up to 0.96. Determination of baseline levels of objective grade were investigated over four age groups (5-85years n= 120) so that in practice a comparison against the ‘normal limits’ could be made. Differences for bulbar hyperaemia were found between the age groups (p<0.001), and also for palpebral redness and roughness (p<0.001). The objective formulae were then applied to the investigation of diurnal variation in order to account for any change that may affect the baseline. Increases in bulbar hyperaemia and palpebral redness were found between examinations in the morning and evening. Correlation factors were recommended. The program was then applied to clinical situations in the form of a contact lens trial and an investigation into iritis and keratoconus where it successfully recognised various surface changes. This programme could become a valuable tool, greatly improving the chances of early detection of anterior ocular abnormalities, and facilitating reliable monitoring of disease progression in clinical as well as research environments.
Resumo:
Purpose: To demonstrate the importance of OCT examination of fellow, normal eyes in unilateral nAMD follow up clinics. Methods: The authors present three cases of unilateral nAMD who were undergoing treatment with ranibizumab, in whom OCT evaluation of the previously unaffected, asymptomatic fellow eye allowed early diagnosis, treatment and preservation of vision. Fundus examination had previously failed to demonstrate abnormality. Results: Intravitreal anti-VEGF treatment for nAMD has caused a sharp increase in the number of subjects attending macular clinics, frequently overburdening the system. It may sometimes be tempting for hospitals to reduce the workload by for example, concentrating only on OCT examination of the affected eye in cases of unilateral nAMD. The three reported cases demonstrate that OCT scanning of the fellow, previously unaffected eye is essential in detecting asymptomatic nAMD, which gives a better chance of preservation of vision. Conclusions: Patients with unilateral neovascular AMD undergoing review in macular clinics should always undergo OCT scanning of normal, fellow eyes, as otherwise asymptomatic, “invisible” choroidal neovascular membranes may be missed.
Resumo:
This work presents a two-dimensional approach of risk assessment method based on the quantification of the probability of the occurrence of contaminant source terms, as well as the assessment of the resultant impacts. The risk is calculated using Monte Carlo simulation methods whereby synthetic contaminant source terms were generated to the same distribution as historically occurring pollution events or a priori potential probability distribution. The spatial and temporal distributions of the generated contaminant concentrations at pre-defined monitoring points within the aquifer were then simulated from repeated realisations using integrated mathematical models. The number of times when user defined ranges of concentration magnitudes were exceeded is quantified as risk. The utilities of the method were demonstrated using hypothetical scenarios, and the risk of pollution from a number of sources all occurring by chance together was evaluated. The results are presented in the form of charts and spatial maps. The generated risk maps show the risk of pollution at each observation borehole, as well as the trends within the study area. This capability to generate synthetic pollution events from numerous potential sources of pollution based on historical frequency of their occurrence proved to be a great asset to the method, and a large benefit over the contemporary methods.
Resumo:
Genetic experiments over the last few decades have identified many regulatory proteins critical for DNA transcription. The dynamics of their transcriptional activities shape the differential expression of the genes they control. Here we describe a simple method, based on the secreted luciferase, to measure the activities of two transcription factors NF?B and HIF. This technique can effectively monitor dynamics of transcriptional events in a population of cells and be up-scaled for high-throughput screening and promoter analysis, making it ideal for data-demanding applications such as mathematical modelling.
Resumo:
Respiratory-volume monitoring is an indispensable part of mechanical ventilation. Here we present a new method of the respiratory-volume measurement based on a single fibre-optical long-period sensor of bending and the correlation between torso curvature and lung volume. Unlike the commonly used air-flow based measurement methods the proposed sensor is drift-free and immune to air-leaks. In the paper, we explain the working principle of sensors, a two-step calibration-test measurement procedure and present results that establish a linear correlation between the change in the local thorax curvature and the change of the lung volume. We also discuss the advantages and limitations of these sensors with respect to the current standards. © 2013 IEEE.
Resumo:
A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber. An array of sensors is also used to reconstruct the shape changes of a resuscitation manikin during simulated respiration. The data for reconstruction is obtained by two methods of multiplexing and interrogation: firstly using the transmission spectral profile of the LPG's attenuation bands measured using an optical spectrum analyser; secondly using a derivative spectroscopy technique.
Resumo:
Defining 'effectiveness' in the context of community mental health teams (CMHTs) has become increasingly difficult under the current pattern of provision required in National Health Service mental health services in England. The aim of this study was to establish the characteristics of multi-professional team working effectiveness in adult CMHTs to develop a new measure of CMHT effectiveness. The study was conducted between May and November 2010 and comprised two stages. Stage 1 used a formative evaluative approach based on the Productivity Measurement and Enhancement System to develop the scale with multiple stakeholder groups over a series of qualitative workshops held in various locations across England. Stage 2 analysed responses from a cross-sectional survey of 1500 members in 135 CMHTs from 11 Mental Health Trusts in England to determine the scale's psychometric properties. Based on an analysis of its structural validity and reliability, the resultant 20-item scale demonstrated good psychometric properties and captured one overall latent factor of CMHT effectiveness comprising seven dimensions: improved service user well-being, creative problem-solving, continuous care, inter-team working, respect between professionals, engagement with carers and therapeutic relationships with service users. The scale will be of significant value to CMHTs and healthcare commissioners both nationally and internationally for monitoring, evaluating and improving team functioning in practice.
Resumo:
Introduction. Peroxiredoxin (PRDX) and thioredoxin (TRX) are antioxidant proteins that control cellular signalling and redox balance, although their response to exercise is unknown. This study aimed to assess key aspects of the PRDX-TRX redox cycle in response to three different modes of exercise. Methods. Healthy males (n = 10, mean ± SD: 22 ± 3 yrs) undertook three exercise trials on separate days: two steady-state cycling trials at moderate (60% VO2MAX; 27 min, MOD) and high (80% VO2MAX; 20 min, HIGH) intensities, and a low-volume high-intensity interval training trial (10 × 1 min 90% VO2MAX, LV-HIIT). Peripheral blood mononuclear cells were assessed for TRX-1 and over-oxidised PRDX (isoforms I-IV) protein expression before, during, and 30 min following exercise (post + 30). The activities of TRX reductase (TRX-R) and the nuclear factor kappa B (NF-κB) p65 subunit were also assessed. Results. TRX-1 increased during exercise in all trials (MOD, + 84.5%; HIGH, + 64.1%; LV-HIIT, + 205.7%; p < 05), whereas over-oxidised PRDX increased during HIGH only (MOD, - 28.7%; HIGH, + 202.9%; LV-HIIT, - 22.7%; p < .05). TRX-R and NF-κB p65 activity increased during exercise in all trials, with the greatest response in TRX-R activity seen in HIGH (p < 0.05). Discussion. All trials stimulated a transient increase in TRX-1 protein expression during exercise. Only HIGH induced a transient over-oxidation of PRDX, alongside the greatest change in TRX-R activity. Future studies are needed to clarify the significance of heightened peroxide exposure during continuous high-intensity exercise and the mechanisms of PRDX-regulatory control.
Resumo:
Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.
Resumo:
Background: Remote, non-invasive and objective tests that can be used to support expert diagnosis for Parkinson's disease (PD) are lacking. Methods: Participants underwent baseline in-clinic assessments, including the Unified Parkinson's Disease Rating Scale (UPDRS), and were provided smartphones with an Android operating system that contained a smartphone application that assessed voice, posture, gait, finger tapping, and response time. Participants then took the smart phones home to perform the five tasks four times a day for a month. Once a week participants had a remote (telemedicine) visit with a Parkinson disease specialist in which a modified (excluding assessments of rigidity and balance) UPDRS performed. Using statistical analyses of the five tasks recorded using the smartphone from 10 individuals with PD and 10 controls, we sought to: (1) discriminate whether the participant had PD and (2) predict the modified motor portion of the UPDRS. Results: Twenty participants performed an average of 2.7 tests per day (68.9% adherence) for the study duration (average of 34.4 days) in a home and community setting. The analyses of the five tasks differed between those with Parkinson disease and those without. In discriminating participants with PD from controls, the mean sensitivity was 96.2% (SD 2%) and mean specificity was 96.9% (SD 1.9%). The mean error in predicting the modified motor component of the UPDRS (range 11-34) was 1.26 UPDRS points (SD 0.16). Conclusion: Measuring PD symptoms via a smartphone is feasible and has potential value as a diagnostic support tool.