2 resultados para Modified Rankin Scale
em Aston University Research Archive
Resumo:
Background: The Aston Medication Adherence Study was designed to examine non-adherence to prescribed medicines within an inner-city population using general practice (GP) prescribing data. Objective: To examine non-adherence patterns to prescribed oralmedications within three chronic disease states and to compare differences in adherence levels between various patient groups to assist the routine identification of low adherence amongst patients within the Heart of Birmingham teaching Primary Care Trust (HoBtPCT). Setting: Patients within the area covered by HoBtPCT (England) prescribed medication for dyslipidaemia, type-2 diabetes and hypothyroidism, between 2000 and 2010 inclusively. HoBtPCT's population was disproportionately young,with seventy per cent of residents fromBlack and Minority Ethnic groups. Method: Systematic computational analysis of all medication issue data from 76 GP surgeries dichotomised patients into two groups (adherent and non-adherent) for each pharmacotherapeutic agent within the treatment groups. Dichotomised groupings were further analysed by recorded patient demographics to identify predictors of lower adherence levels. Results were compared to an analysis of a self-reportmeasure of adherence [using the Modified Morisky Scale© (MMAS-8)] and clinical value data (cholesterol values) from GP surgery records. Main outcome: Adherence levels for different patient demographics, for patients within specific longterm treatment groups. Results: Analysis within all three groups showed that for patients with the following characteristics, adherence levels were statistically lower than for others; patients: younger than 60 years of age; whose religion is coded as "Islam"; whose ethnicity is coded as one of the Asian groupings or as "Caribbean", "Other Black" and "African"; whose primary language is coded as "Urdu" or "Bengali"; and whose postcodes indicate that they live within the most socioeconomically deprived areas of HoBtPCT. Statistically significant correlations between adherence status and results from the selfreport measure of adherence and of clinical value data analysis were found. Conclusion: Using data fromGP prescribing systems, a computerised tool to calculate individual adherence levels for oral pharmacotherapy for the treatment of diabetes, dyslipidaemia and hypothyroidism has been developed.The tool has been used to establish nonadherence levels within the three treatment groups and the demographic characteristics indicative of lower adherence levels, which in turn will enable the targeting of interventional support within HoBtPCT. © Koninklijke Nederlandse Maatschappij ter bevordering der Pharmacie 2013.
Resumo:
A study of the hydrodynamics and mass transfer characteristics of a liquid-liquid extraction process in a 450 mm diameter, 4.30 m high Rotating Disc Contactor (R.D.C.) has been undertaken. The literature relating to this type of extractor and the relevant phenomena, such as droplet break-up and coalescence, drop mass transfer and axial mixing has been revjewed. Experiments were performed using the system C1airsol-350-acetone-water and the effects of drop size, drop size-distribution and dispersed phase hold-up on the performance of the R.D.C. established. The results obtained for the two-phase system C1airso1-water have been compared with published correlations: since most of these correlations are based on data obtained from laboratory scale R.D.C.'s, a wide divergence was found. The hydrodynamics data from this study have therefore been correlated to predict the drop size and the dispersed phase hold-up and agreement has been obtained with the experimental data to within +8% for the drop size and +9% for the dispersed phase hold-up. The correlations obtained were modified to include terms involving column dimensions and the data have been correlated with the results obtained from this study together with published data; agreement was generally within +17% for drop size and within +14% for the dispersed phase hold-up. The experimental drop size distributions obtained were in excellent agreement with the upper limit log-normal distributions which should therefore be used in preference to other distribution functions. In the calculation of the overall experimental mass transfer coefficient the mean driving force was determined from the concentration profile along the column using Simpson's Rule and a novel method was developed to calculate the overall theoretical mass transfer coefficient Kca1, involving the drop size distribution diagram to determine the volume percentage of stagnant, circulating and oscillating drops in the sample population. Individual mass transfer coefficients were determined for the corresponding droplet state using different single drop mass transfer models. Kca1 was then calculated as the fractional sum of these individual coefficients and their proportions in the drop sample population. Very good agreement was found between the experimental and theoretical overall mass transfer coefficients. Drop sizes under mass transfer conditions were strongly dependant upon the direction of mass transfer. Drop Sizes in the absence of mass transfer were generally larger than those with solute transfer from the continuous to the dispersed phase, but smaller than those with solute transfer in the opposite direction at corresponding phase flowrates and rotor speed. Under similar operating conditions hold-up was also affected by mass transfer; it was higher when solute transfered from the continuous to the dispersed phase and lower when direction was reversed compared with non-mass transfer operation.