27 resultados para Methicillin-resistant Staphylococcus aureus

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Principal components analysis (PCA) has been described for over 50 years; however, it is rarely applied to the analysis of epidemiological data. In this study PCA was critically appraised in its ability to reveal relationships between pulsed-field gel electrophoresis (PFGE) profiles of methicillin- resistant Staphylococcus aureus (MRSA) in comparison to the more commonly employed cluster analysis and representation by dendrograms. The PFGE type following SmaI chromosomal digest was determined for 44 multidrug-resistant hospital-acquired methicillin-resistant S. aureus (MR-HA-MRSA) isolates, two multidrug-resistant community-acquired MRSA (MR-CA-MRSA), 50 hospital-acquired MRSA (HA-MRSA) isolates (from the University Hospital Birmingham, NHS Trust, UK) and 34 community-acquired MRSA (CA-MRSA) isolates (from general practitioners in Birmingham, UK). Strain relatedness was determined using Dice band-matching with UPGMA clustering and PCA. The results indicated that PCA revealed relationships between MRSA strains, which were more strongly correlated with known epidemiology, most likely because, unlike cluster analysis, PCA does not have the constraint of generating a hierarchic classification. In addition, PCA provides the opportunity for further analysis to identify key polymorphic bands within complex genotypic profiles, which is not always possible with dendrograms. Here we provide a detailed description of a PCA method for the analysis of PFGE profiles to complement further the epidemiological study of infectious disease. © 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The number, diversity and restriction enzyme fragmentation patterns of plasmids harboured by 44 multidrug-resistant hospital-acquired methicillin-resistant Staphylococcus aureus (MR-HA-MRSA) isolates, two multidrug-resistant community-acquired MRSA (MR-CA-MRSA), 50 hospital-acquired MRSA (HA-MRSA) isolates (from the University Hospital Birmingham, NHS Trust, UK) and 34 community-acquired MRSA (CA-MRSA) isolates (from general practitioners in Birmingham, UK) were compared. In addition, pulsed-field gel electrophoresis (PFGE) type following SmaI chromosomal digest and SCCmec element type assignment were ascertained for each isolate. All MR-HA-MRSA and MR-CA-MRSA isolates possessed the type II SCCmec, harboured no plasmid DNA and belonged to one of five PFGE types. Forty-three out of 50 HA-MRSA isolates and all 34 CA-MRSA isolates possessed the type IV SCCmec and all but 10 of the type IV HA-MRSA isolates and nine CA-MRSA isolates carried one or two plasmids. The 19 non-multidrug-resistant isolates (NMR) that did not harbour plasmids were only resistant to methicillin whereas all the NMR isolates harbouring at least one plasmid were resistant to at least one additional antibiotic. We conclude that although plasmid carriage plays an important role in antibiotic resistance, especially in NMR-HA-MRSA and CA-MRSA, the multidrug resistance phenotype from HA-MRSA is not associated with increased plasmid carriage and indeed is characterised by an absence of plasmid DNA. © 2005 Federation of European Microbiological Societies. Published by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyze the recent epidemiology of methicillin-resistant Staphylococcus aureus (MRSA) bacteremia in a UK tertiary referral center. Methods: We collected epidemiological and laboratory data on all cases of MRSA bacteremia from September 1, 2005 to December 31, 2007. Results: There were 195 clinically significant episodes. Most were hospital-acquired. Only one episode occurred in patients without a history of hospital admission in the previous 12 months. An intravascular device was the most common focus of infection (37%), with no identifiable source found in 35% of episodes. Twenty-eight percent of patients died within 30 days of bacteremia. Mortality was significantly higher in the absence of an identifiable focus. Failure to include an antibiotic active against MRSA in the empirical treatment was only significantly associated with death in patients showing signs of hemodynamic instability (p < 0.001). No isolates had a minimum inhibitory concentration to vancomycin above 1.5. mg/l and no heteroresistance to glycopeptide antibiotics (heteroresistant vancomycin-intermediate Staphylococcus aureus; hVISA) was detected. All isolates were sensitive to daptomycin, tigecycline, and linezolid. Conclusions: Despite improvement in infection control measures, medical devices remain the most common source of infection. Inappropriate empirical antibiotic usage is associated with a poor outcome in patients with signs of severe sepsis. Susceptibility to glycopeptides and newer antibiotics remains good. © 2010 International Society for Infectious Diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since 1999, the European Antimicrobial Resistance Surveillance System (EARSS) has monitored the rise in infection due to a number of organisms, including meticillin-resistant Staphylococcus aureus (MRSA). The EARSS reported that MRSA infections within intensive care units account for 25-50% of infections in many central and southern European countries, these included France, Spain, Great Britain, Malta, Greece and Italy. Each country has defined epidemic MRSA (EMRSA) strains; however, the method of spread of these strains from one country to another is unknown. In this current study, DNA profiles of 473 isolates of MRSA collected from the UK and Malta were determined by PFGE. Analysis of the data showed that two countries separated by a large geographical distance had a similar DNA profile pattern. Additionally it was demonstrated that strains of EMRSA normally found in the UK were also found in the Maltese cohort (EMRSA 15 and 16). A distinct DNA profile was found in the Maltese cohort, which may be a local EMRSA, and accounted for 14.4% of all Maltese isolates. The appearance of the same MRSA and EMRSA profiles in two separate countries suggests that MRSA can be transferred out of their country of origin and potentially establish in a new locality or country.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Between January 2005 and December 2005, 199 meticillin-resistant Staphylococcus aureus (MRSA) isolates were obtained from nonhospitalised patients presenting skin and soft tissue infections to local general practitioners. The study area incorporated 57 surgeries from three Primary Care Trusts in the Lichfield, Tamworth, Burntwood, North and East Birmingham regions of Central England, UK. Following antibiotic susceptibility testing, pulsed-field gel electrophoresis, Panton-Valentine leukocidin gene detection and SCCmec element assignment, 95% of the isolates were shown to be related to hospital epidemic strains EMRSA-15 and EMRSA-16. In total 87% of the isolate population harboured SCCmec IV, 9% had SCCmec II and 4% were identified as carrying novel SCCmec IIIa-mecI. When mapped to patient home postcode, a diverse distribution of isolates harbouring SCCmec II and SCCmec IV was observed; however, the majority of isolates harbouring SCCmec IIIa-mecI were from patients residing in the north-west of the study region, highlighting a possible localised clonal group. Transmission of MRSA from the hospital setting into the surrounding community population, as demonstrated by this study, warrants the need for targeted patient screening and decolonisation in both the clinical and community environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antibiotic resistance is an increasing problem in isolates of Staphylococcus aureus (S. aureus) worldwide. In 2001 The National Health Service in the UK introduced a mandatory bacteraemia surveillance scheme for the reporting of S. aureus and methicillin-resistant S. aureus (MRSA). This surveillance initiative reports on the percentage of isolates that are methicillin resistant. However, resistance to other antibiotics is not currently reported and therefore the scale of emerging resistance is currently unclear in the UK. In this study, multiple antibiotic resistance (MAR) profiles against fourteen antimicrobial drugs were investigated for 705 isolates of S. aureus collected from two European study sites in the UK (London) and Malta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There has been a persistent increase in the number of meticillin-resistant Staphylococcus aureus (MRSA) and meticillin-susceptible Staphylococcus aureus (MSSA) bacteraemia in the UK. This prospective study included 147 episodes of S. aureus bacteraemia in 139 patients over a 14 month period, from 1 November 2001 to 31 December 2002. Eighty-seven (59%) episodes in 84 patients and 60 (41%) in 56 patients were due to MRSA and MSSA, respectively. An intra-vascular device (29, 33%) and a soft-tissue (15, 25%) source were the commonest identifiable foci for bacteraemia in the MRSA and MSSA groups, respectively. Attributable mortality in the MRSA group was higher than the MSSA group (33% vs 16%; P = 0.03) but there was no statistical difference for either attributable (P = 0.35) or crude (P = 0.39) mortality between the two groups, when adjusted for age, respiratory focus and inappropriate antibiotic therapy. A respiratory source (P = 0.02) and inappropriate antibiotic therapy (P = 0.02) were associated with attributable mortality in the MRSA group whereas advanced age was the only risk factor (P = 0.02) in the MSSA group. The present study shows that S. aureus bacteraemia continues to be a serious infection mostly affecting the elderly and emphasizes the need for improved strategy in the control and management of this condition. © 2006 The Hospital Infection Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Persistent contamination of surfaces by spores of Clostridium difficile is a major factor influencing the spread of C. difficile-associated diarrhoea (CDAD) in the clinical setting. In recent years, the antimicrobial efficacy of metal surfaces has been investigated against microorganisms including methicillin-resistant Staphylococcus aureus. This study compared the survival of C. difficile on stainless steel, a metal contact surface widely used in hospitals, and copper surfaces. METHODS: Antimicrobial efficacy was assessed using a carrier test method against dormant spores, germinating spores and vegetative cells of C. difficile (NCTC 11204 and ribotype 027) over a 3 h period in the presence and absence of organic matter. RESULTS: Copper metal eliminated all vegetative cells of C. difficile within 30 min, compared with stainless steel which demonstrated no antimicrobial activity (P < 0.05). Copper significantly reduced the viability of spores of C. difficile exposed to the germinant (sodium taurocholate) in aerobic conditions within 60 min (P < 0.05) while achieving a >or=2.5 log reduction (99.8% reduction) at 3 h. Organic material did not reduce the antimicrobial efficacy of the copper surface (P > 0.05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The identification of disease clusters in space or space-time is of vital importance for public health policy and action. In the case of methicillin-resistant Staphylococcus aureus (MRSA), it is particularly important to distinguish between community and health care-associated infections, and to identify reservoirs of infection. 832 cases of MRSA in the West Midlands (UK) were tested for clustering and evidence of community transmission, after being geo-located to the centroids of UK unit postcodes (postal areas roughly equivalent to Zip+4 zip code areas). An age-stratified analysis was also carried out at the coarser spatial resolution of UK Census Output Areas. Stochastic simulation and kernel density estimation were combined to identify significant local clusters of MRSA (p<0.025), which were supported by SaTScan spatial and spatio-temporal scan. In order to investigate local sampling effort, a spatial 'random labelling' approach was used, with MRSA as cases and MSSA (methicillin-sensitive S. aureus) as controls. Heavy sampling in general was a response to MRSA outbreaks, which in turn appeared to be associated with medical care environments. The significance of clusters identified by kernel estimation was independently supported by information on the locations and client groups of nursing homes, and by preliminary molecular typing of isolates. In the absence of occupational/ lifestyle data on patients, the assumption was made that an individual's location and consequent risk is adequately represented by their residential postcode. The problems of this assumption are discussed, with recommendations for future data collection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effective surface disinfection is a fundamental infection control strategy within healthcare. This study assessed the antimicrobial efficacy of novel biocide formulations comprising 5% and 2% eucalyptus oil (EO) combined with 2% chlorhexidine digluconate (CHG) and 70% isopropyl alcohol (IPA) contained within a wipe. The efficacy of this novel antimicrobial formulation to remove and eliminate methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli and Candida albicans from steel surfaces was investigated. Adpression studies of pre-contaminated wipes were also utilised to assess their potential to induce cross-contamination between hard surfaces. Furthermore, the bactericidal nature of the EO-formulation was established in addition to time-kill. The EO-containing formulations demonstrated bactericidal antimicrobial efficacy against all microorganisms and did not induce surface cross-contamination. There was no significant difference (p < 0.05) between the 5% and 2% EO formulations in their ability to remove microorganisms from steel surfaces, however both significantly (p < 0.05) removed more than the control formulations. Microbial biofilms were eliminated within 10 min (p < 0.05) when exposed to the EO formulations. Our novel EO-formulation demonstrated rapid antimicrobial efficacy for potential disinfection and elimination of microbial biofilms from hard surfaces and may therefore be a useful adjunct to current infection control strategies currently employed within healthcare facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The antimicrobial efficacy of a chlorhexidine gluconate (CHG) intravascular catheter gel dressing was evaluated against methicillin-resistant Staphylococcus aureus (MRSA) and an extended-spectrum β-lactamase (ESBL)-producing Escherichia coli. Chlorhexidine deposition on the skin surface and release from the gel were determined. Methods: The antimicrobial efficacy was evaluated in in vitro studies following microbial inoculation of the dressing and application of the dressing on the inoculated surface of a silicone membrane and donor skin [with and without a catheter segment and/or 10% (v/v) serum] on diffusion cells. Antimicrobial activity was evaluated for up to 7 days. Chlorhexidine skin surface deposition and release were also determined. Results: MRSA and E. coli were not detectable within 5 min following direct inoculation onto the CHG gel dressing. On the silicone membrane, 3 log and 6 log inocula of MRSA were eradicated within 5 min and 1 h, respectively. Time to kill was prolonged in the presence of serum and a catheter segment. Following inoculation of donor skin with 6 log cfu of MRSA, none was detected after 24 h. Chlorhexidine was released from the gel after a lag time of 30 min and increasing amounts were detected on the donor skin surface over the 48 h test period. The CHG gel dressing retained its antimicrobial activity on the artificial skin for 7 days. Conclusions: The CHG intravascular catheter site gel dressing had detectable antimicrobial activity for up to 7 days, which should suppress bacterial growth on the skin at the catheter insertion site, thereby reducing the risk of infection. © The Author 2011. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved.