21 resultados para Metaphors on Vision

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To examine the effect of uncorrected astigmatism in older adults. SETTING: University Vision Clinic METHOD: Twenty-one healthy presbyopes, aged 58.9±2.8 years, had astigmatism of 0.0 to -4.0 x 90?DC and -3.0DC of cylinder at 90?, 180? and 45? induced with spectacle lenses, with the mean spherical equivalent compensated to plano, in random order. Visual acuity was assessed binocularly using a computerised test chart at 95%, 50% and 10% contrast. Near acuity and reading speed were measured using standardised reading texts. Light scatter was quantified with the cQuant and driving reaction times with a computer simulator. Finally visual clarity of a mobile phone and computer screen was subjectively rated. RESULTS: Distance visual acuity decreased with increasing uncorrected astigmatic power (F=174.50, p<0.001) and was reduced at lower contrasts (F=170.77, p<0.001). Near visual acuity and reading speed also decreased with increasing uncorrected astigmatism power (p<0.001). Light scatter was not significantly affected by uncorrected astigmatism (p>0.05), but the reliability and variability of measurements decreased with increasing uncorrected astigmatic power (p<0.05). Driving simulator performance was also unaffected by uncorrected astigmatism (p>0.05), but subjective rating of clarity decreased with increasing uncorrected astigmatic power (p<0.001). Uncorrected astigmatism at 45? or 180? orientation resulted in a worse distance and near visual acuity, and subjective rated clarity than 90? orientation (p<0.05). CONCLUSION: Uncorrected astigmatism, even as low as 1.0DC, causes a significant burden on a patient’s vision. If left uncorrected, this could impact significantly on their independence, quality of life and wellbeing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To show that the limited quality of surfaces produced by one model of excimer laser systems can degrade visual performance with a polymethylmethacrylate (PMMA) model. METHODS: A range of lenses of different powers was ablated in PMMA sheets using five DOS-based Nidek EC-5000 laser systems (Nidek Technologies, Gamagori, Japan) from different clinics. Surface quality was objectively assessed using profilometry. Contrast sensitivity and visual acuity were measured through the lenses when their powers were neutralized with suitable spectacle trial lenses. RESULTS: Average surface roughness was found to increase with lens power, roughness values being higher for negative lenses than for positive lenses. Losses in visual contrast sensitivity and acuity measured in two subjects were found to follow a similar pattern. Findings are similar to those previously published with other excimer laser systems. CONCLUSIONS: Levels of surface roughness produced by some laser systems may be sufficient to degrade visual performance under some circumstances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principal aim of this work was to examine the effects of antiepileptic drugs (AEDs) on vision. Vigabatrin acts by increasing GABA at brain inhibitory synapses by irreversibly binding to GABA-transaminase. Remacemide is a novel non-competitive NMDA receptor antagonist and fast sodium channel inhibitor that results in the inhibition of the NMDA receptors located in the neuronal membrane calcium channels increasing glutamate in the brain. Vigabatrin has been shown to cause a specific pattern of visual field loss, as one in three adults taking vigabatrin have shown a bilateral concentric constriction. Remacemide has unknown effects on vision. The majority of studies of the effects of AEDs on vision have not included the paediatric population due to difficulties assessing visual field function using standard perimetry testing. Evidently an alternative test is required to establish and monitor visual field problems associated with AEDs both in children and in adults who cannot comply with perimetry. In order to test paediatric patients exposed to vigabatrin, a field-specific visual evoked potential was developed. Other tests performed on patients taking either vigabatrin or remacemide were electroretinograms, electro-oculograms, multifocal VEPs and perimetry. Comparing these tests to perimetry results from vigabatrin patients the field specific VEP was found to have a high sensitivity and specificity, as did the 30Hz flicker amplitude. The modified VEP was also found to provide useful results in vigabatrin patients. Remacemide did not produce a similar visual field loss to vigabatrin although macular vision was affected. The field specific VEP is a useful method for detecting vigabatrin associated visual field loss that is well tolerated by young children. This technique combined with the ERG under light adapted (30Hz flicker) condition is presently the superior method for detecting vigabatrin-attributed peripheral field defects present in children below the developmental age of 9. The effects of AEDs on vision should be monitored carefully and the use of multifocal stimulation allows for specific areas of the retina and visual pathway to be monitored.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The object of the study was to investigate, establish and quantify the relationship between contrast sensitivity, intraocular light scatter and glare. The aim was to establish the effects on vision, in an effort to provide a more comprehensive understanding of the visual world of subjects prone to increased light scatter in the eye. Disability glare refers to the reduction in visual performance produced by a glare source. The reduction in visual performance can be explained by intraocular scattered light producing a veiling luminance which is superimposed upon the retinal image. This veiling luminance lowers contrast thus sensitivity to the stimulus declines. The effect of glare of luminance and colour contrast sensitivity for young and elderly subjects was examined. For both age groups, disability glare was greatest for the red-green stimulus and least for the blue-yellow. The precise effect of a glare source on colour discrimination depends upon the interaction between the chromaticity of the glare source and that of the stimulus. The effect of a long wavelength pass (red) and a short wavelength pass filter (blue) on disability glare was examined. Disability glare was not significantly different with the red and blue filters, even in the presence of wavelength dependent scatter. An equation was derived which allowed an intrinsic Light Scatter Factor (LSF) to be determined for any given glare angle (Paulsson and Sjöstrand, 1980). Corrections to the formula to account for factors such as pupil size changes are unnecessary. The results confirm the suitability of measuring the LSF using contrast threshold with and without glare, provided that appropriate methods are used. Using this formula an investigation into the amount of wavelength dependent scatter indicated that wavelength dependent scatter in normal young, elderly or cataractous eyes is of little or no significance. Finally, it seemed desirable to investigate the effect ultraviolet (UV) radiation has on intraocular light scatter and subsequently visual performance. Overall the results indicated that the presence or absence of UV radiation has relatively little effect on visual function for the young, elderly or cataract patient.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Audio feedback remains little used in most graphical user interfaces despite its potential to greatly enhance interaction. Not only does sonic enhancement of interfaces permit more natural human-computer communication but it also allows users to employ an appropriate sense to solve a problem rather than having to rely solely on vision. Research shows that designers do not typically know how to use sound effectively; subsequently, their ad hoc use of sound often leads to audio feedback being considered an annoying distraction. Unlike the design of purely graphical user interfaces for which guidelines are common, the audio-enhancement of graphical user interfaces has (until now) been plagued by a lack of suitable guidance. This paper presents a series of empirically substantiated guidelines for the design and use of audio-enhanced graphical user interface widgets.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Vitamin and mineral deficiencies are common in developing countries, but also occur in developed countries. We review micronutrient deficiencies for the major vitamins A, cobalamin (B-12), biotin (vitamin H), vitamins C and E, as well as the minerals iron, and zinc, in the developed world, in terms of their relationship to systemic health and any resulting ocular disease and/or visual dysfunction. A knowledge of these effects is important as individuals with consequent poor ocular health and reduced visual function may present for ophthalmic care.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract: Loss of central vision caused by age-related macular degeneration (AMD) is a problem affecting increasingly large numbers of people within the ageing population. AMD is the leading cause of blindness in the developed world, with estimates of over 600,000 people affected in the UK . Central vision loss can be devastating for the sufferer, with vision loss impacting on the ability to carry out daily activities. In particular, inability to read is linked to higher rates of depression in AMD sufferers compared to age-matched controls. Methods to improve reading ability in the presence of central vision loss will help maintain independence and quality of life for those affected. Various attempts to improve reading with central vision loss have been made. Most textual manipulations, including font size, have led to only modest gains in reading speed. Previous experimental work and theoretical arguments on spatial integrative properties of the peripheral retina suggest that ‘visual crowding’ may be a major factor contributing to inefficient reading. Crowding refers to the phenomena in which juxtaposed targets viewed eccentrically may be difficult to identify. Manipulating text spacing of reading material may be a simple method that reduces crowding and benefits reading ability in macular disease patients. In this thesis the effect of textual manipulation on reading speed was investigated, firstly for normally sighted observers using eccentric viewing, and secondly for observers with central vision loss. Test stimuli mimicked normal reading conditions by using whole sentences that required normal saccadic eye movements and observer comprehension. Preliminary measures on normally-sighted observers (n = 2) used forced-choice procedures in conjunction with the method of constant stimuli. Psychometric functions relating the proportion of correct responses to exposure time were determined for text size, font type (Lucida Sans and Times New Roman) and text spacing, with threshold exposure time (75% correct responses) used as a measure of reading performance. The results of these initial measures were used to derive an appropriate search space, in terms of text spacing, for assessing reading performance in AMD patients. The main clinical measures were completed on a group of macular disease sufferers (n=24). Firstly, high and low contrast reading acuity and critical print size were measured using modified MNREAD test charts, and secondly, the effect of word and line spacing was investigated using a new test, designed specifically for this study, called the Equal Readability Passages (ERP) test. The results from normally-sighted observers were in close agreement with those from the group of macular disease sufferers. Results show that: (i) optimum reading performance was achieved when using both double line and double word spacing; (ii) the effect of line spacing was greater than the effect of word spacing (iii) a text size of approximately 0.85o is sufficiently large for reading at 5o eccentricity. In conclusion, the results suggest that crowding is detrimental to reading with peripheral vision, and its effects can be minimized with a modest increase in text spacing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Magnification can be provided to assist those with visual impairment to make the best use of remaining vision. Electronic transverse magnification of an object was first conceived for use in low vision in the late 1950s, but has developed slowly and is not extensively prescribed because of its relatively high cost and lack of portability. Electronic devices providing transverse magnification have been termed closed-circuit televisions (CCTVs) because of the direct cable link between the camera imaging system and monitor viewing system, but this description generally refers to surveillance devices and does not indicate the provision of features such as magnification and contrast enhancement. Therefore, the term Electronic Vision Enhancement Systems (EVES) is proposed to better distinguish and describe such devices. This paper reviews current knowledge on EVES for the visually impaired in terms of: classification; hardware and software (development of technology, magnification and field-of-view, contrast and image enhancement); user aspects (users and usage, reading speed and duration, and training); and potential future development of EVES. © 2003 The College of Optometrists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background - The aim was to derive equations for the relationship between unaided vision and age, pupil diameter, iris colour and sphero-cylindrical refractive error. Methods - Data were collected from 663 healthy right eyes of white subjects aged 20 to 70 years. Subjective sphero-cylindrical refractive errors ranged from -6.8 to +9.4 D (mean spherical equivalent), -1.5 to +1.9 D (orthogonal component, J0) and -0.8 to 1.0 D (oblique component, J45). Cylinder axis orientation was orthogonal in 46 per cent of the eyes and oblique in 18 per cent. Unaided vision (-0.3 to +1.3 logMAR), pupil diameter (2.3 to 7.5 mm) and iris colour (67 per cent light/blue irides) was recorded. The sample included mostly females (60 per cent) and many contact lens wearers (42 per cent) and so the influences of these parameters were also investigated. Results - Decision tree analysis showed that sex, iris colour, contact lens wear and cylinder axis orientation did not influence the relationship between unaided vision and refractive error. New equations for the dependence of the minimum angle of resolution on age and pupil diameter arose from step backwards multiple linear regressions carried out separately on the myopes (2.91.scalar vector +0.51.pupil diameter -3.14 ) and hyperopes (1.55.scalar vector + 0.06.age – 3.45 ). Conclusion - The new equations may be useful in simulators designed for teaching purposes as they accounted for 81 per cent (for myopes) and 53 per cent (for hyperopes) of the variance in measured data. In comparison, previously published equations accounted for not more than 76 per cent (for myopes) and 24 per cent (for hyperopes) of the variance depending on whether they included pupil size. The new equations are, as far as is known to the authors, the first to include age. The age-related decline in accommodation is reflected in the equation for hyperopes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Since 1972, the Australian College of Optometry has worked in partnership with Vision Australia to provide multidisciplinary low-vision care at the Kooyong Low Vision Clinic. In 1999, Wolffsohn and Cochrane reported on the demographic characteristics of patients attending Kooyong. Sixteen years on, the aim of this study is to review the demographics of the Kooyong patient cohort and prescribing patterns. METHODS: Records of all new patients (n = 155) attending the Kooyong Low Vision Clinic for optometry services between April and September 2012 were retrospectively reviewed. RESULTS: Median age was 84.3 years (range 7.7 to 98.1 years) with 59 per cent female. The majority of patients presented with late-onset degenerative pathology, 49 per cent with a primary diagnosis of age-related macular degeneration. Many (47.1 per cent) lived with their families. Mean distance visual acuity was 0.57 ± 0.47 logMAR or approximately 6/24. The median spectacle-corrected near visual acuity was N8 (range N3 to worse than N80). Fifty patients (32.3 per cent) were prescribed new spectacles, 51 (32.9 per cent) low vision aids and five (8.3 per cent) were prescribed electronic magnification devices. Almost two-thirds (63.9 per cent) were referred for occupational therapy management and 12.3 per cent for orientation and mobility services. CONCLUSIONS: The profile of patients presenting for low-vision services at Kooyong is broadly similar to that identified in 1999. Outcomes appear to be similar, aside from an expected increase in electronic devices and technological solutions; however, the nature of services is changing, as treatments for ocular diseases advance and assistive technology develops and becomes more accessible. Alongside the aging population and age-related ocular disease being the predominant cause of low vision in Australia, the health-funding landscape is becoming more restrictive. The challenge for the future will be to provide timely, high-quality care in an economically efficient model.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Age-related macular degeneration (ARMD) is a major cause of irreversible visual loss in the elderly and a significant threat to their quality of life. Although low vision services often improve the functional outcomes of individuals with macular disease, it remains unclear whether or not they have any impact on quality of life. The principal aim of this study was to determine the effect of a hospital-based low vision clinic on the quality of life of individuals with ARMD. Methods: Forty patients with ARMD attended the low vision clinic at Milton Keynes University Hospital. Quality of life was measured with the vision-specific Low Vision Quality of Life (LVQOL) questionnaire and the general health EuroQol (EQ-5D-5L) questionnaire. Measures were completed at baseline (time zero, T0), and at three- (T3) and six-month (T6) follow-up visits. Results: The near visual acuity of individuals attending the low vision clinic for the first time improved significantly between visits T0 and T3 (p=0.005), reflecting the practiced use of their newly-dispensed low vision aids. As expected, there was no significant change in near acuity over this time period for existing patients. For both new and existing patients, a significant increase in LVQOL score was evident between visits T0 and T3, with a further significant improvement between T3 and T6. Similarly, there was a significant decrease in EQ-5D-5L questionnaire scores between visits T0 and T6. Conclusions: The higher LVQOL scores obtained at the end of the study period (T6) provide evidence that low vision services at Milton Keynes University Hospital served to improve patient quality of life. The reduction in EQ-5D-5L scores over the same time period suggests that low vision services also provide for an improvement in general health-related quality of life. Impact: The findings support the cause of low vision services to improve not only the vision and functional outcomes of individuals with macular disease but also their quality of life. Moreover, the findings suggest that a more efficient allocation of resources at low vision clinics may be possible through the standardisation of patient follow-up frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This book provides the first comprehensive analysis of metaphors used by Hugo Chávez in his efforts to construct and legitimize his Bolivarian Revolution. It focuses on metaphors drawn from three of his most frequent target domains: the nation, his revolution, and the opposition. The author argues that behind an official discourse of inclusion, Chávez's choice of metaphors contributes to the construction of a polarizing discourse of exclusion in which his political opponents are represented as enemies of the nation. Chávez constructs this polarizing discourse of exclusion by combining metaphors that conceptualize: (a) the nation as a person who has been resurrected by his government, as a person ready to fight for his revolution, or as Chávez himself; (b) the revolution as war; and (c) members of the opposition as war combatants or criminals. At the same time, by making explicit references in his discourse about the revolution as the continuation of Simón Bolívar's wars of independence, Chávez contributes to represent opponents as enemies of the nation, given that in the Venezuelan collective imaginary Bolívar is the symbol of the nation's emancipation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The MacDQoL is an individualised measure of the impact of macular degeneration (MD) on quality of life (QoL). There is preliminary evidence of its psychometric properties and sensitivity to severity of MD. The aim of this study was to carry out further psychometric evaluation with a larger sample and investigate the measure's sensitivity to MD severity. Methods: Patients with MD (n = 156: 99 women, 57 men, mean age 79 ± 13 years), recruited from eye clinics (one NHS, one private) completed the MacDQoL by telephone interview and later underwent a clinic vision assessment including near and distance visual acuity (VA), comfortable near VA, contrast sensitivity, colour recognition, recovery from glare and presence or absence of distortion or scotoma in the central 10° of the visual field. Results: The completion rate for the MacDQoL items was 99.8%. Of the 26 items, three were dropped from the measure due to redundancy. A fourth was retained in the questionnaire but excluded when computing the scale score. Principal components analysis and Cronbach's alpha (0.944) supported combining the remaining 22 items in a single scale. Lower MacDQoL scores, indicating more negative impact of MD on QoL, were associated with poorer distance VA (better eye r = -0.431 p < 0.001; worse eye r = -0.350 p < 0.001; binocular vision r = -0.419 p < 0.001) and near VA (better eye r -0.326 p < 0.001; worse eye r = -0.226 p < 0.001; binocular vision r = -0.326 p < 0.001). Poorer MacDQoL scores were associated with poorer contrast sensitivity (better eye r = 0.392 p < 0.001; binocular vision r = 0.423 p < 0.001), poorer colour recognition (r = 0.417 p < 0.001) and poorer comfortable near VA (r = -0.283, p < 0.001). The MacDQoL differentiated between those with and without binocular scotoma (U = 1244 p < 0.001). Conclusion: The MacDQoL 22-item scale has excellent internal consistency reliability and a single-factor structure. The measure is acceptable to respondents and the generic QoL item, MD-specific QoL item and average weighted impact score are related to several measures of vision. The MacDQoL demonstrates that MD has considerable negative impact on many aspects of QoL, particularly independence, leisure activities, dealing with personal affairs and mobility. The measure may be valuable for use in clinical trials and routine clinical care. © 2005 Mitchell et al; licensee BioMed Central Ltd.