38 resultados para Measurement range
em Aston University Research Archive
Resumo:
Distributed fibre sensors provide unique capabilities for monitoring large infrastructures with high resolution. Practically, all these sensors are based on some kind of backscattering interaction. A pulsed activating signal is launched on one side of the sensing fibre and the backscattered signal is read as a function of the time of flight of the pulse along the fibre. A key limitation in the measurement range of all these sensors is introduced by fibre attenuation. As the pulse travels along the fibre, the losses in the fibre cause a drop of signal contrast and consequently a growth in the measurement uncertainty. In typical single-mode fibres, attenuation imposes a range limit of less than 30km, for resolutions in the order of 1-2 meters. An interesting improvement in this performance can be considered by using distributed amplification along the fibre [1]. Distributed amplification allows having a more homogeneous signal power along the sensing fibre, which also enables reducing the signal power at the input and therefore avoiding nonlinearities. However, in long structures (≥ 50 km), plain distributed amplification does not perfectly compensate the losses and significant power variations along the fibre are to be expected, leading to inevitable limitations in the measurements. From this perspective, it is simple to understand intuitively that the best possible solution for distributed sensors would be offered by a virtually transparent fibre, i.e. a fibre exhibiting effectively zero attenuation in the spectral region of the pulse. In addition, it can be shown that lossless transmission is the working point that allows the minimization of the amplified spontaneous emission (ASE) noise build-up. © 2011 IEEE.
Resumo:
We propose a novel technique for optical liquid level sensing. The technique takes advantage of an optical spectrum spreading technique and directly measures liquid level with a digital format. The performance of the sensor does not suffer from changes of environmental variables and system variables. Due to its distinct measurement principle both high resolution and a large measurement range can be achieved simultaneously.
Resumo:
The study investigated the potential applications and the limitations of non-standard techniques of visual field investigation utilizing automated perimetry. Normal subjects exhibited a greater sensitivity to kinetic stimuli than to static stimuli of identical size. The magnitude of physiological SKD was found to be largely independent of age, stimulus size, meridian and eccentricity. The absence of a dependency on stimulus size indicated that successive lateral spatial summation could not totally account for the underlying mechanism of physiological SKD. The visual field indices MD and LV exhibited a progressive deterioration during the time course of a conventional central visual field examination both for normal subjects and for ocular hypertensive patients. The fatigue effect was more pronounced in the latter stages and for the second eye tested. The confidence limits for the definition of abnormality should reflect the greater effect of fatigue on the second eye. A 330 cdm-2 yellow background was employed for blue-on-yellow perimetry. Instrument measurement range was preserved by positioning a concave mirror behind the stimulus bulb to increase the light output by 60% . The mean magnitude of SWS pathway isolation was approximately 1.4 log units relative to a 460nm stimulus filter. The absorption spectra of the ocular media exhibited an exponential increase with increase in age, whilst that of the macular pigment showed no systematic trend. The magnitude of ocular media absorption was demonstrated to reduce with increase in wavelength. Ocular media absorption was significantly greater in diabetic patients than in normal subjects. Five diabetic patients with either normal or borderline achromatic sensitivity exhibited an abnormal blue-on-yellow sensitivity; two of these patients showed no signs of retinopathy. A greater vulnerability of the SWS pathway to the diabetic disease process was hypothesized.
Resumo:
The fabrication of in-fibre Bragg gratings (FBGs) and their application as sensors is reported. The strain and temperature characteristic results for a number of chirped and uniform gratings written into three different host fibres are presented. The static and dynamic temperature response of a commercially available temperature compensated grating is reported. A five sensor wavelength division multiplexed fibre Bragg grating strain measurement system with an interrogation rate of 25 Hz and resolution of 10 was constructed. The results from this system are presented. A novel chirped FBG interrogation method was implemented in both the 1.3 and 1.5 m telecommunication windows. Several single and dual strain sensor systems, employing this method, were constructed and the results obtained from each are reported and discussed. These systems are particularly suitable for the measurement of large strain. The results from a system measuring up to 12 m and with a potential measurement range of 30 m are reported. This technique is also shown to give an obtainable resolution of 20 over a measurement range of 5 000 for a dual sensor system. These systems are simple, robust, passive and easy to implement. They offer low cost, high speed and, in the case of multiple sensors, truly simultaneous interrogation. These advantages make this technique ideal for strain sensing in SMART structures. Systems based on this method have been installed in the masts of four superyachts. A system, based on this technique, is currently being developed for the measurement of acoustic waves in carbon composite panels. The results from an alternative method for interrogating uniform FBG sensors are also discussed. Interrogation of the gratings was facilitated by a specifically written asymmetric grating which had a 15 nm long linearly sloped spectral edge. This technique was employed to interrogate a single sensor over a measurement range of 6 m and two sensors over a range of 4.5 me. The results obtained indicated achievable resolutions of 47 and 38 respectively.
Resumo:
An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.
Resumo:
An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.
Resumo:
A highly sensitive liquid-level sensor based on dual-wavelength single-longitudinal-mode fiber laser is proposed and demonstrated. The laser is formed by exploiting two parallel arranged phase-shift fiber Bragg gratings (ps-FBGs), acting as ultra-narrow bandwidth filters, into a doublering resonators. By beating the dual-wavelength lasing output, a stable microwave signal with frequency stability better than 5 MHz is obtained. The generated beat frequency varies with the change of dual-wavelength spacing. Based on this characteristic, with one ps-FBG serving as the sensing element and the other one acting as the reference element, a highly sensitive liquid level sensor is realized by monitoring the beat frequency shift of the laser. The sensor head is directly bonded to a float which can transfer buoyancy into axial strain on the fiber without introducing other elastic elements. The experimental results show that an ultra-high liquidlevel sensitivity of 2.12 × 107 MHz/m within the measurement range of 1.5 mm is achieved. The sensor presents multiple merits including ultra-high sensitivity, thermal insensitive, good reliability and stability. © 2012 Optical Society of America.
Resumo:
The amplification of demand variation up a supply chain widely termed ‘the Bullwhip Effect’ is disruptive, costly and something that supply chain management generally seeks to minimise. Originally attributed to poor system design; deficiencies in policies, organisation structure and delays in material and information flow all lead to sub-optimal reorder point calculation. It has since been attributed to exogenous random factors such as: uncertainties in demand, supply and distribution lead time but these causes are not exclusive as academic and operational studies since have shown that orders and/or inventories can exhibit significant variability even if customer demand and lead time are deterministic. This increase in the range of possible causes of dynamic behaviour indicates that our understanding of the phenomenon is far from complete. One possible, yet previously unexplored, factor that may influence dynamic behaviour in supply chains is the application and operation of supply chain performance measures. Organisations monitoring and responding to their adopted key performance metrics will make operational changes and this action may influence the level of dynamics within the supply chain, possibly degrading the performance of the very system they were intended to measure. In order to explore this a plausible abstraction of the operational responses to the Supply Chain Council’s SCOR® (Supply Chain Operations Reference) model was incorporated into a classic Beer Game distribution representation, using the dynamic discrete event simulation software Simul8. During the simulation the five SCOR Supply Chain Performance Attributes: Reliability, Responsiveness, Flexibility, Cost and Utilisation were continuously monitored and compared to established targets. Operational adjustments to the; reorder point, transportation modes and production capacity (where appropriate) for three independent supply chain roles were made and the degree of dynamic behaviour in the Supply Chain measured, using the ratio of the standard deviation of upstream demand relative to the standard deviation of the downstream demand. Factors employed to build the detailed model include: variable retail demand, order transmission, transportation delays, production delays, capacity constraints demand multipliers and demand averaging periods. Five dimensions of supply chain performance were monitored independently in three autonomous supply chain roles and operational settings adjusted accordingly. Uniqueness of this research stems from the application of the five SCOR performance attributes with modelled operational responses in a dynamic discrete event simulation model. This project makes its primary contribution to knowledge by measuring the impact, on supply chain dynamics, of applying a representative performance measurement system.
Resumo:
The involvement of oxidatively modified low density lipoprotein (LDL) in the development of CHD is widely described. We have produced two antibodies, recognizing the lipid oxidation product malondialdehyde (MDA) on whole LDL or ApoB-100. The antibodies were utilized in the development of an ELISA for quantitation of MDA-LDL in human plasma. Intra- and inter-assay coefficients of variation (% CV) were measured as 4.8 and 7.7%, respectively, and sensitivity of the assay as 0.04 μg/ml MDA-LDL. Recovery of standard MDA-LDL from native LDL was 102%, indicating the ELISA to be specific with no interference from other biomolecules. Further validation of the ELISA was carried out against two established methods for measurement of lipid peroxidation products, MDA by HPLC and F2-isoprostanes by GC-MS. Results indicated that MDA-LDL is formed at a later stage of oxidation than either MDA or F2- isoprostanes. In vivo analysis demonstrated that the ELISA was able to determine steady-state concentrations of plasma MDA-LDL (an end marker of lipid peroxidation). A reference range of 34.3 ± 8.8 μg/ml MDA-LDL was established for healthy individuals. Further, the ELISA was used to show significantly increased plasma MDA-LDL levels in subjects with confirmed ischemic heart disease, and could therefore possibly be of benefit as a diagnostic tool for assessing CHD risk. © 2003 Elsevier Inc.
Resumo:
Background/aims Macular pigment is thought to protect the macula against exposure to light and oxidative stress, both of which may play a role in the development of age-related macular degeneration. The aim was to clinically evaluate a novel cathode-ray-tube-based method for measurement of macular pigment optical density (MPOD) known as apparent motion photometry (AMP). Methods The authors took repeat readings of MPOD centrally (0°) and at 3° eccentricity for 76 healthy subjects (mean (±SD) 26.5±13.2 years, range 18–74 years). Results The overall mean MPOD for the cohort was 0.50±0.24 at 0°, and 0.28±0.20 at 3° eccentricity; these values were significantly different (t=-8.905, p<0.001). The coefficients of repeatability were 0.60 and 0.48 for the 0 and 3° measurements respectively. Conclusions The data suggest that when the same operator is taking repeated 0° AMP MPOD readings over time, only changes of more than 0.60 units can be classed as clinically significant. In other words, AMP is not suitable for monitoring changes in MPOD over time, as increases of this magnitude would not be expected, even in response to dietary modification or nutritional supplementation.
Resumo:
Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.
Resumo:
This article describes a 6-yr study of the radial growth rates (RGR, mm yr-1) of Rhizocarpon section Rhizocarpon thalli on a talus slope at Snoqualmie Pass in the Cascade Range, Washington State, United States (47°27'N; 121°26'W). At the end of the growth period, 32 of a total of 39 thalli had exhibited a positive RGR, and 7 of a total of 39 thalli showed no measurable growth. Mean RGR of all thalli was 0.07 mm yr-1 (range, 0-0.19 mm, SD = 0.06). Analysis of variance suggested no significant variation in RGR in successive growth periods, but significant differences were present both within and between thalli. The slope of a boulder facet did not influence RGR, but growth was affected by aspect, the least growth being observed on north-northwest facets. A plot of RGR against thallus diameter revealed a wide scatter of data points with little evidence for a significant change in growth with thallus size. Hence, the study showed that the RGR of Rhizocarpon thalli at Snoqualmie is extremely slow and highly variable and significantly less than estimates based on lichenometry. To determine the growth curve of a yellow-green Rhizocarpon by direct measurement at such a site would require a large sample of thalli and careful standardization of the species studied, the aspect conditions under which the thalli were measured, and the initial hypothallus width of the thalli. © 2005 Regents of the University of Colorado.