59 resultados para Mach-Zehnder interferometers

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dibit recovery of a DQPSK signal will be demonstrated using a single Mach Zehnder Interferometer, containing a 1-bit delay, and a single balanced receiver. The electrical output levels of the balanced receiver are dependent upon the relative phase delay between the arms of the Mach Zehnder Interferometer. This paper will investigate this characteristic when the input signal is DQPSK modulated. It will also be shown that with a certain amount of phase shift the DQPSK signal can be converted into four different equally spaced electrical signal levels. With each decoded level representing one of the four possible dibits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research the recovery of a DQPSK signal will be demonstrated using a single Mach-Zehnder Interferometer (MZI). By changing the phase delay in one of the arms it will be shown that different delays will produce different output levels. It will also be shown that with a certain level of phase shift the DQPSK signal can be converted into four different equally spaced optical power levels. With each decoded level representing one of the four possible bit permutations. By using this additional phase shift in one of the arms the number of MZIs required for decoding can be reduced from two to one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A low cost interrogation scheme is demonstrated for a refractometer based on an in-line fiber long period grating (LPG) Mach–Zehnder interferometer. Using this interrogation scheme the minimum detectable change in refractive index of ?n ~ 1.8×10-6 is obtained, which is the highest resolution achieved using a fiber LPG device, and is comparable to precision techniques used in the industry including high performance liquid chromatography and ultraviolet spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical first order calculation of the impact of Gaussian white noise on a novel single Mach-Zehnder Interferometer demodulation scheme for DQPSK reveals a constant Q factor ratio to the conventional scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented is a study on a single-drive dual-parallel Mach-Zehnder modulator implementation as a single sideband suppressed carrier generator. High values of both extinction ratio and sidemode suppression ratio were obtained at different modulation frequencies over the Cband. In addition, a stabilisation loop had been developed to preserve the single sideband generation over time. © The Institution of Engineering and Technology 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new fibre Mach-Zehnder type based on a single LPG written in a biconical fibre taper is presented alongside a theoretical model supporting the observed effect

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A refractive index sensing system has been demonstrated, which is based upon an in-line fibre long period grating Mach-Zehnder interferometer with a heterodyne interrogation technique. This sensing system has comparable accuracy to laboratory-based techniques used in industry such as high performance liquid chromatography and UV spectroscopy. The advantage of this system is that measurements can be made in-situ for applications in continuous process control. Compared to other refractive index sensing schemes using LPGs, this approach has two main advantages. Firstly, the system relies on a simple optical interrogation system and therefore has the real potential for being low cost, and secondly, so far as we are aware it provides the highest refractive index resolution reported for any fibre LPG device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An approach to realizing simultaneous measurement of refractive index (RI) and temperature based on a microfiber-based dual inline Mach-Zehnder interferometer (MZI) is proposed and demonstrated. Due to different interference mechanisms, as one interference between the core mode and the lower order cladding mode in the sensing single-mode fiber and the other interference between the fundamental mode and the high-order mode in the multimode microfiber, the former interferometer achieves RI sensitivity of -23.67 nm/RIU and temperature sensitivity of 81.2 pm/oC, whereas those of the latter are 3820.23 nm/RIU, and -465.7 pm/oC, respectively. The large sensitivity differences can provide a more accurate demodulation of RI and temperature. The sensor is featured with multiparameters measurement, compact structure, high sensitivity, low cost, and easy fabrication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multimode microfiber (MMMF)-based dual Mach-Zehnder interferometer (MZI) is proposed and demonstrated for simultaneous measurement of refractive index (RI) and temperature. By inserting a section of MMMFsupporting a few modes in the sensing arm of the MZI setup, an inline interference between the fundamental mode and the high-order mode of MMMF, as well as the interference between the high-order mode of MMMF and the reference arm, i.e., the dual MZI, is realized. Due to different interference mechanisms, the former interferometer achieves RI sensitivity of 2576.584 nm/RIU and temperature sensitivity of 0.193 nm/°C, while the latter one achieves RI sensitivity of 1001.864 nm/RIU and temperature sensitivity of 0.239 nm/°C, demonstrating the ability to attain highly accurate multiparameter measurements. © 2014 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bending sensor is achieved by employing a singlemode fiber-dual core photonic crystal fiber- singlemode fiber (SDS) structure with two tapers at fusing points. A sensitivity of - 4.3421nm/m∼ between the transmission spectra shift and curvature is demonstrated. © 2013 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose an in-fiber Mach-Zehnder interferometer formed by a pair of largely tilted fiber gratings. The interference spectral characteristics have been investigated. The experimental results using this device as a chemical sensor have a sensitivity as high as 719nm/RIU. © 2012 OSA.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We propose a new method for the simultaneous interrogation of conventional two-beam interferometers and Bragg grating sensors. The technique employs an unbalanced Mach-Zehnder interferometer illuminated by a single low-coherence source, which acts as a wavelength-tunable source for the grating and as a path-matched f ilter for the Fizeau interferometer, thus providing a high phase resolution output for each sensor. The grating sensor demonstrates a dynamic strain resolution of ~0.05 µe/vHz at 20 Hz, while the interferometric phase resolution is better than 1 mrad/vHz at 20 Hz, corresponding to an rms mirror displacement of 0.08 nm.