10 resultados para Lower limbs power
em Aston University Research Archive
Resumo:
Through a lumped parameter modelling approach, a dynamical model, which can reproduce the motion of the muscles of a human body standing in different postures during Whole Body Vibrations (WBVs) treatment, has been developed. The key parameters, associated to the dynamics of the motion of the muscles of the lower limbs, have been identified starting from accelerometer measurements. The developed model can be usefully applied to the optimization of WBVs treatments which can effectively enhance muscle activation. © 2013 IEEE.
Resumo:
This study examined the influence of organizational justice perceptions on employee work outcome relationships as moderated by individual differences that are influenced by societal culture. Power distance, but not country or individualism, moderated the relationships between perceived justice and satisfaction, performance, and absenteeism. The effects of perceived justice on these outcomes were stronger among individuals scoring lower on power distance index, and most of these study participants were in the U.S. (versus Hong Kong) sample. Limitations of the study and the implications of the findings for managing cross-culturally are discussed.
Resumo:
Here, for the first time, we experimentally demonstrate optical data transmission through such quasi-lossless fibre spans, which provide an entirely different nonlinear propagation regime to conventionally EDFA/Raman amplified systems. We demonstrate 42.6 Gb/s transmission over 2500 km of SMF-28 with an 82 km span length, and investigate the optimisation of the system in terms of launch power and nonlinear tolerance. Our results show the first ever data transmission experiment using an ultra-long Raman laser to provide quasi-lossless conditions in the transmission fibre. For a span length of 82 km we have shown 2500 km transmission over SMF-28 fibre at 42.6 Gb/s. Our quasi-lossless configuration had 6 dB lower optimum power and improved nonlinear tolerance compared with a conventional EDFA only system.
Resumo:
The replacement of diesel fuel by ultra-carbofluids was perceived to offer the potential to decrease the emissions of environmental pollutants such as carbon dioxide, carbon monoxide, hydrocarbons (HC's) and smoke. Such ultracarbofluids consist of a suspension of coal in fuel oil and water generally in the ratio of 5: 3: 2 plus a small amount of stabilising additive. The literature relating to the economies of coal and fuel oil production, and the production and properties of charcoal and vegetable oils has been critically reviewed. The potential use of charcoal and vegetable oils as replacements for coal and fuel oil are discussed. An experimental investigation was undertaken using novel bio-ultracarbofluid formulations. These differed from an ultracarbofluid by having bio-renewable charcoal and vegetable oil in place of coal and fuel oil. Tests were made with a Lister-Petter 600cc 2-cylinder, 4-stroke diesel engine fitted with a Heenan-Froude DPX 1 water brake dynamometer to measure brake power output, and Mexa-321E and Mexa-211E analysers to measure exhaust pollutants. Measurements were made of engine brake power output, carbon dioxide, carbon monoxide, hydrocarbons and smoke emissions over the speed range 1000 to 3000 rpm at 200 rpm intervals. The results were compared with those obtained with a standard diesel reference fuel. All the bio-ultracarbofluid formulations produced lower brake power outputs (i.e. 5.6% to 20.7% less brake power) but substantially improved exhaust emissions of CO2, CO, HC's and smoke. The major factor in the formulation was found to be the type and amount of charcoal; charcoal with a high volatile content (27.2%) and present at 30% by mass yielded the best results, i.e. only slightly lower brake power output and significantly lower exhaust pollutants.
Resumo:
Here, for the first time, we experimentally demonstrate optical data transmission through such quasi-lossless fibre spans, which provide an entirely different nonlinear propagation regime to conventionally EDFA/Raman amplified systems. We demonstrate 42.6 Gb/s transmission over 2500 km of SMF-28 with an 82 km span length, and investigate the optimisation of the system in terms of launch power and nonlinear tolerance. Our results show the first ever data transmission experiment using an ultra-long Raman laser to provide quasi-lossless conditions in the transmission fibre. For a span length of 82 km we have shown 2500 km transmission over SMF-28 fibre at 42.6 Gb/s. Our quasi-lossless configuration had 6 dB lower optimum power and improved nonlinear tolerance compared with a conventional EDFA only system.
Resumo:
We investigated 50 young patients with a diagnosis of Rolandic Epilepsy (RE) for the presence of abnormalities in autonomic tone compared with 50 young patients with idiopathic generalized epilepsy with absences and 50 typically developing children of comparable age. We analyzed time domain (N-N interval, pNN50) and frequency domain (High Frequency (HF), Low Frequency (LF) and LF/HF ratio) indices from ten-minute resting EKG activity. Patients with RE showed significantly higher HF and lower LF power and lower LF/HF ratio than controls, independent of the epilepsy group, and did not show significant differences in any other autonomic index with respect to the two control groups. In RE, we found a negative relationship between both seizure load and frequency of sleep interictal EEG abnormalities with parasympathetic drive levels. These changes might be the expression of adaptive mechanisms to prevent the excessive sympathetic drive seen in patients with refractory epilepsies. © 2012 Elsevier Inc.
Resumo:
This research employs econometric analysis on a cross section of American electricity companies in order to study the cost implications associated with unbundling the operations of integrated companies into vertically and/or horizontally separated companies. Focusing on the representative sample average firm, we find that complete horizontal and vertical disintegration resulting in the creation of separate nuclear, conventional, and hydro electric generation companies as well as a separate firm distributing power to final consumers, results in a statistically significant 13.5 percent increase in costs. Maintaining a horizontally integrated generator producing nuclear, conventional, and hydro electric generation while imposing vertical separation by creating a stand alone distribution company, results in a lower but still substantial and statistically significant cost penalty amounting to an 8.1 % increase in costs relative to a fully integrated structure. As these results imply that a vertically separated but horizontally integrated generation firm would need to reduce the costs of generation by 11% just to recoup the cost increases associated with vertical separation, even the costs associated with just vertical unbundling are quite substantial. Our paper is also the first academic paper we are aware of that systematically considers the impact of generation mix on vertical, horizontal, and overall scope economies. As a result, we are able to demonstrate that the estimated cost of unbundling in the electricity sector is substantially influenced by generation mix. Thus, for example, we find evidence of strong vertical integration economies between nuclear and conventional generation, but little evidence for vertical integration benefits between hydro generation and the distribution of power. In contrast, we find strong evidence suggesting the presence of substantial horizontal integration economies associated with the joint production of hydro generation with nuclear and/or conventional fossil fuel generation. These results are significant because they indicate that the cost of unbundling the electricity sector will differ substantially in different systems, meaning that a blanket regulatory policy with regard to the appropriateness of vertical and horizontal unbundling is likely to be inappropriate.
Resumo:
This paper presents an assessment of the technical and economic performance of thermal processes to generate electricity from a wood chip feedstock by combustion, gasification and fast pyrolysis. The scope of the work begins with the delivery of a wood chip feedstock at a conversion plant and ends with the supply of electricity to the grid, incorporating wood chip preparation, thermal conversion, and electricity generation in dual fuel diesel engines. Net generating capacities of 1–20 MWe are evaluated. The techno-economic assessment is achieved through the development of a suite of models that are combined to give cost and performance data for the integrated system. The models include feed pretreatment, combustion, atmospheric and pressure gasification, fast pyrolysis with pyrolysis liquid storage and transport (an optional step in de-coupled systems) and diesel engine or turbine power generation. The models calculate system efficiencies, capital costs and production costs. An identical methodology is applied in the development of all the models so that all of the results are directly comparable. The electricity production costs have been calculated for 10th plant systems, indicating the costs that are achievable in the medium term after the high initial costs associated with novel technologies have reduced. The costs converge at the larger scale with the mean electricity price paid in the EU by a large consumer, and there is therefore potential for fast pyrolysis and diesel engine systems to sell electricity directly to large consumers or for on-site generation. However, competition will be fierce at all capacities since electricity production costs vary only slightly between the four biomass to electricity systems that are evaluated. Systems de-coupling is one way that the fast pyrolysis and diesel engine system can distinguish itself from the other conversion technologies. Evaluations in this work show that situations requiring several remote generators are much better served by a large fast pyrolysis plant that supplies fuel to de-coupled diesel engines than by constructing an entire close-coupled system at each generating site. Another advantage of de-coupling is that the fast pyrolysis conversion step and the diesel engine generation step can operate independently, with intermediate storage of the fast pyrolysis liquid fuel, increasing overall reliability. Peak load or seasonal power requirements would also benefit from de-coupling since a small fast pyrolysis plant could operate continuously to produce fuel that is stored for use in the engine on demand. Current electricity production costs for a fast pyrolysis and diesel engine system are 0.091/kWh at 1 MWe when learning effects are included. These systems are handicapped by the typical characteristics of a novel technology: high capital cost, high labour, and low reliability. As such the more established combustion and steam cycle produces lower cost electricity under current conditions. The fast pyrolysis and diesel engine system is a low capital cost option but it also suffers from relatively low system efficiency particularly at high capacities. This low efficiency is the result of a low conversion efficiency of feed energy into the pyrolysis liquid, because of the energy in the char by-product. A sensitivity analysis has highlighted the high impact on electricity production costs of the fast pyrolysis liquids yield. The liquids yield should be set realistically during design, and it should be maintained in practice by careful attention to plant operation and feed quality. Another problem is the high power consumption during feedstock grinding. Efficiencies may be enhanced in ablative fast pyrolysis which can tolerate a chipped feedstock. This has yet to be demonstrated at commercial scale. In summary, the fast pyrolysis and diesel engine system has great potential to generate electricity at a profit in the long term, and at a lower cost than any other biomass to electricity system at small scale. This future viability can only be achieved through the construction of early plant that could, in the short term, be more expensive than the combustion alternative. Profitability in the short term can best be achieved by exploiting niches in the market place and specific features of fast pyrolysis. These include: •countries or regions with fiscal incentives for renewable energy such as premium electricity prices or capital grants; •locations with high electricity prices so that electricity can be sold direct to large consumers or generated on-site by companies who wish to reduce their consumption from the grid; •waste disposal opportunities where feedstocks can attract a gate fee rather than incur a cost; •the ability to store fast pyrolysis liquids as a buffer against shutdowns or as a fuel for peak-load generating plant; •de-coupling opportunities where a large, single pyrolysis plant supplies fuel to several small and remote generators; •small-scale combined heat and power opportunities; •sales of the excess char, although a market has yet to be established for this by-product; and •potential co-production of speciality chemicals and fuel for power generation in fast pyrolysis systems.
Resumo:
This paper is part of a project which aims to research the opportunities for the re-use of batteries after their primary use in low and ultra low carbon vehicles on the electricity grid system. One potential revenue stream is to provide primary/secondary/high frequency response to National Grid through market mechanisms via DNO's or Energy service providers. Some commercial battery energy storage systems (BESS) already exist on the grid system, but these tend to use costly new or high performance batteries. Second life batteries should be available at lower cost than new batteries but reliability becomes an important issue as individual batteries may suffer from degraded performance or failure. Therefore converter topology design could be used to influence the overall system reliability. A detailed reliability calculation of different single phase battery-to-grid converter interfacing schemes is presented. A suitable converter topology for robust and reliable BESS is recommended.
Resumo:
A novel open-winding brushless doubly-fed generator (BDFG) system with two two-level bidirectional converters is proposed. This topology is equivalent to a three-level bidirectional converter connected to the typical BDFG, but solves the unbalanced-voltage-division problem of DC capacitor in the three-level converter, and has lower converter capacity, more flexible control mode, and better fault-tolerant ability. The direct power control (DPC) based on the twelve sections is adopted to implement the power tracking of the open-winding BDFG system, which is compared with the typical BDFG DPC system based on the six and twelve sections to verify the advantages of the proposed scheme.