19 resultados para Low-voltage applications

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A proposal to increase the existing residential LV grid voltage from 230 V to 300 V has been made in order to increase existing network capacity. A power-electronic AC-AC converter is then used to provide 230 V at each property. The equipment can also provide power-quality improvements to the network and load. Several constraints such as temperature rise at the converter location lead to a converter design requiring very high efficiency. In this paper different AC/AC converter topologies are presented which compares the power quality benefits, size and efficiency of each converter. The design and the control technique of the most suitable topology are verified using simulation and preliminary experimentally results of prototype hardware are also included. © 2013 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infection is a major clinical problem associated with the use of intravenous catheters.The efficacy of a direct electric current (10µA, 9V) via electrode-conducting carbon impregnated catheters to prevent colonisation of catheters by micro-organisms was investigated. The range of organisms susceptible to 10µA was determined by a zone of inhibition test. The catheters acting as the anode and the cathode were inserted into a nutrient agar plate inoculated with a lawn of bacteria. There was no zone of inhibition observed around the anode. Organisms susceptible to 10µA at the cathode were Staphylococcus aureus (2 strains), Staphylococcus epidermidis (5 strains), Escherichia coli and Klebsiella pneumoniae (2 strains each), and one strain of the following micro-organisms: Staphylococcus hominis, Proteus mirabilis, Pseudomonas aeruginosa and Candida albicans. The zones ranged from 6 to 16 mm in diameter according to the organisms under test. The zone size was proportional to the amperage (10 - 100 µA) and the number of organisms on the plate. Ten µA did not prevent adhesion of staphylococci to the cathode nor did it affect their growth in nutrient broth. However, it was bactericidal to adherent bacteria on the cathodal catheter and significantly reduced the number of bacteria on the catheter after 4 to 24 h application of electricity. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated.The mechanisms of the bactericidal activity associated with the cathode were investigated with S. epidermidis and S. aureus. The inhibition zone was greatly reduced in the presence of catalase. There was no zone around the cathode when the test was carried out under anaerobic conditions. Hydrogen peroxide was produced at the cathode surface under aerobic conditions, but not in the absence of oxygen. A salt-bridge apparatus was used to demonstrate further that hydrogen peroxide was produced at the cathode, and chlorine at the anode. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated. Antibacterial activity was reduced under anaerobic conditions, which is compatible with the role of hydrogen peroxide as a primary bactericidal agent of electricity associated with the cathode. A reduction in chloride ions did not significantly reduce the antibacterial activity suggesting chlorine plays only a minor role in the bactericidal activity against organisms attached to anodal electrode surfaces. The bactericidal activity of electric current associated with the cathode and H202 was greatly reduced in the presence of 50 μM to 0.5 mM magnesium ions in the test menstrum. Ten μA applied via the catheters did not prevent the initial biofilm growth by the adherent bacteria but reduced the number of bacteria in the biofilm by 2 log order aiter 24 h. The results suggested that 10 μA may prevent the colonisation of catheters by both the extra~ and intra-luminal routes. The localised production of hydrogen peroxide and chlorine and the intrinsic activity due to electric current may offer a useful method for the eradication of bacteria from catheter surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an urgent need for fast, non-destructive and quantitative two-dimensional dopant profiling of modern and future ultra large-scale semiconductor devices. The low voltage scanning electron microscope (LVSEM) has emerged to satisfy this need, in part, whereby it is possible to detect different secondary electron yield values (brightness in the SEM signal) from the p-type to the n-type doped regions as well as different brightness levels from the same dopant type. The mechanism that gives rise to such a secondary electron (SE) contrast effect is not fully understood, however. A review of the different models that have been proposed to explain this SE contrast is given. We report on new experiments that support the proposal that this contrast is due to the establishment of metal-to-semiconductor surface contacts. Further experiments showing the effect of instrument parameters including the electron dose, the scan speeds and the electron beam energy on the SE contrast are also reported. Preliminary results on the dependence of the SE contrast on the existence of a surface structure featuring metal-oxide semiconductor (MOS) are also reported. Copyright © 2005 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports work of a MEng student final year project, which looks in detail at the impacts that distributed generation can have on existing low-voltage distribution network protection systems. After a review of up-to-date protection issues, this paper will investigate several key issues that face distributed generation connections when it comes to network protection systems. These issues include, the blinding of protection systems, failure to automatically reclose, unintentional islanding, loss of mains power and the false tripping of feeders. Each of these problems impacts on protection systems in its own way. This study aims to review and investigate these problems via simulation demonstrations on one representative network to recommend solutions to practices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The realisation of an eventual low-voltage (LV) Smart Grid with a complete communication infrastructure is a gradual process. During this evolution the protection scheme of distribution networks should be continuously adapted and optimised to fit the protection and cost requirements at the time. This paper aims to review practices and research around the design of an effective, adaptive and economical distribution network protection scheme. The background of this topic is introduced and potential problems are defined from conventional protection theories and new Smart Grid technologies. Challenges are identified with possible solutions defined as a pathway to the ultimate flexible and reliable LV protection systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of low energy nitrogen molecular ion beam bombardment on metals and compound semiconductors has been studied, with the aim to investigate at the effects of ion and target properties. For this purpose, nitrogen ion implantation in aluminium, iron, copper, gold, GaAs and AIGaAs is studied using XPS and Angle Resolve XPS. A series of experimental studies on N+2 bombardment induced compositional changes, especially the amount of nitrogen retained in the target, were accomplished. Both monoenergetic implantation and non-monoenergetic ion implantation were investigated, using the VG Scientific ESCALAB 200D system and a d. c. plasma cell, respectively. When the samples, with the exception of gold, are exposed to air, native oxide layers are formed on the surfaces. In the case of monoenergetic implantation, the surfaces were cleaned using Ar+ beam bombardment prior to implantation. The materials were then bombarded with N2+ beam and eight sets of successful experiments were performed on each sample, using a rastered N2+ ion beam of energy of 2, 3, 4 and 5 keV with current densities of 1 μA/cm2 and 5 μA/cm22 for each energy. The bombarded samples were examined by ARXPS. After each complete implantation, XPS depth profiles were created using Ar+ beam at energy 2 ke V and current density 2 μA/cm2 . As the current density was chosen as one of the parameters, accurate determination of current density was very important. In the case of glow discharge, two sets of successful experiments were performed in each case, by exposing the samples to nitrogen plasma for the two conditions: at low pressure and high voltage and high pressure and low voltage. These samples were then examined by ARXPS. On the theoretical side, the major problem was prediction of the number of ions of an element that can be implanted in a given matrix. Although the programme is essentially on experimental study, but an attempt is being made to understand the current theoretical models, such as SATVAL, SUSPRE and TRIM. The experimental results were compared with theoretical predictions, in order to gain a better understanding of the mechanisms responsible. From the experimental results, considering possible experimental uncertainties, there is no evidence of significant variation in nitrogen saturation concentration with ion energy or ion current density in the range of 2-5 ke V, however, the retention characteristics of implantant seem to strongly depend on the chemical reactivity between ion species and target material. The experimental data suggests the presence of at least one thermal process. The discrepancy between the theoretical and experimental results could be the inability of the codes to account for molecular ion impact and thermal processes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A status report of the modelling and simulation work that is being undertaken as part of the TIMES (Totally Integrated More Electric Systems) project is presented. Dynamic power quality simulations have been used to asses the performance of the electrical system of a EMA based actuation system for an Airbus A330 size aircraft, for both low voltage 115 V, and high voltage 230 V three-phase AC systems. The high voltage system is shown to have benefits in terms of power quality and reduced size and weight of equipment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A fine control of the mPOF Bragg grating spectrum properties, such as maximum reflected power and 3dB bandwidth, through acousto-optic modulation (AOM) using flexural regime is presented. A numerical comparison of the strain field along mPOFBG - AOM and the similar structure with SMFBG-AOM was presented, showing that the strain field amplitude is higher along the mPOFBG due to its smaller mechanical stiffness. The obtained results can be used in the development of fine-tuned optical filters using low voltage sources and low frequency regimes, to obtain tunable optical filters and to control the shape of the spectrum. Studies of the behavior in different gratings (such as phase shifted and long period gratings) for photonic applications, such as tunable notch filters or tunable cavities, are in progress. It can potentially be applied on tunable optical filters for POF transmission. © 2012 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Photovoltaic (PV) stations have been widely built in the world to utilize solar energy directly. In order to reduce the capital and operational costs, early fault diagnosis is playing an increasingly important role by enabling the long effective operation of PV arrays. This paper analyzes the terminal characteristics of faulty PV strings and arrays, and it develops a PV array fault diagnosis technique. The terminal current-voltage curve of a faulty PV array is divided into two sections, i.e., high-voltage and low-voltage fault diagnosis sections. The corresponding working points of healthy string modules and of healthy and faulty modules in an unhealthy string are then analyzed for each section. By probing into different working points, a faulty PV module can be located. The fault information is of critical importance for the maximum power point tracking and the array dynamical reconfiguration. Furthermore, the string current sensors can be eliminated, and the number of voltage sensors can be reduced by optimizing voltage sensor locations. Typical fault scenarios including monostring, multistring, and a partial shadow for a 1.6-kW 3 $times$ 3 PV array are presented and experimentally tested to confirm the effectiveness of the proposed fault diagnosis method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In order to increase the capacity of the existing Low Voltage grid, one solution is to increase the nominal residential network voltage from 230 V to 300 V, which is easily accommodated within the voltage rating of existing infrastructure such as cabling. A power electronic AC-AC converter would then be used to step the voltage back down to 230 V at an individual property. Such equipment could also be used to provide power quality improvements on both the utility and customer side of the converter depending on its topology. This paper provides an overview of a project which is looking at the development of such a device. The project is being carried out in collaboration with the local UK, Distribution Network Operator (DNO).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To carry out stability studies on more electric systems in which there is a preponderance of motor drive equipment, input admittance expressions are required for the individual pieces of equipment. In this paper the techniques of averaging and small-signal linearisation will be used to derive a simple input admittance model for a low voltage, trapezoidal back EMF, brushless, DC motor drive system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper proposes a novel dc-dc converter topology to achieve an ultrahigh step-up ratio while maintaining a high conversion efficiency. It adopts a three degree of freedom approach in the circuit design. It also demonstrates the flexibility of the proposed converter to combine with the features of modularity, electrical isolation, soft-switching, low voltage stress on switching devices, and is thus considered to be an improved topology over traditional dc-dc converters. New control strategies including the two-section output voltage control and cell idle control are also developed to improve the converter performance. With the cell idle control, the secondary winding inductance of the idle module is bypassed to decrease its power loss. A 400-W dc-dc converter is prototyped and tested to verify the proposed techniques, in addition to a simulation study. The step-up conversion ratio can reach 1:14 with a peak efficiency of 94% and the proposed techniques can be applied to a wide range of high voltage and high power distributed generation and dc power transmission.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The work presented in this thesis describes an investigation into the production and properties of thin amorphous C films, with and without Cr doping, as a low wear / friction coating applicable to MEMS and other micro- and nano-engineering applications. Firstly, an assessment was made of the available testing techniques. Secondly, the optimised test methods were applied to a series of sputtered films of thickness 10 - 2000 nm in order to: (i) investigate the effect of thickness on the properties of coatingslcoating process (ii) investigate fundamental tribology at the nano-scale and (iii) provide a starting point for nanotribological coating optimisation at ultra low thickness. The use of XPS was investigated for the determination of Sp3/Sp2 carbon bonding. Under C 1s peak analysis, significant errors were identified and this was attributed to the absence of sufficient instrument resolution to guide the component peak structure (even with a high resolution instrument). A simple peak width analysis and correlation work with C KLL D value confirmed the errors. The use of XPS for Sp3/Sp2 was therefore limited to initial tentative estimations. Nanoindentation was shown to provide consistent hardness and reduced modulus results with depth (to < 7nm) when replicate data was suitably statistically processed. No significant pile-up or cracking of the films was identified under nanoindentation. Nanowear experimentation by multiple nanoscratching provided some useful information, however the conditions of test were very different to those expect for MEMS and micro- / nano-engineering systems. A novel 'sample oscillated nanoindentation' system was developed for testing nanowear under more relevant conditions. The films were produced in an industrial production coating line. In order to maximise the available information and to take account of uncontrolled process variation a statistical design of experiment procedure was used to investigate the effect of four key process control parameters. Cr doping was the most significant control parameter at all thicknesses tested and produced a softening effect and thus increased nanowear. Substrate bias voltage was also a significant parameter and produced hardening and a wear reducing effect at all thicknesses tested. The use of a Cr adhesion layer produced beneficial results at 150 nm thickness, but was ineffective at 50 nm. Argon flow to the coating chamber produced a complex effect. All effects reduced significantly with reducing film thickness. Classic fretting wear was produced at low amplitude under nanowear testing. Reciprocating sliding was produced at higher amplitude which generated three body abrasive wear and this was generally consistent with the Archard model. Specific wear rates were very low (typically 10-16 - 10-18 m3N-1m-1). Wear rates reduced exponentially with reduced film thickness and below (approx.) 20 nm, thickness was identified as the most important control of wear.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To carry out stability and voltage regulation studies on more electric aircraft systems in which there is a preponderance of multi-pulse, rectifier-fed motor-drive equipment, average dynamic models of the rectifier converters are required. Existing methods are difficult to apply to anything other than single converters with a low pulse number. Therefore an efficient, compact method for deriving the approximate, linear, average model of 6- and 12-pulse rectifiers, based on the assumption of a small duration of the overlap angle is presented. The models are validated against detailed simulations and laboratory prototypes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This research develops a low cost remote sensing system for use in agricultural applications. The important features of the system are that it monitors the near infrared and it incorporates position and attitude measuring equipment allowing for geo-rectified images to be produced without the use of ground control points. The equipment is designed to be hand held and hence requires no structural modification to the aircraft. The portable remote sensing system consists of an inertia measurement unit (IMU), which is accelerometer based, a low-cost GPS device and a small format false colour composite digital camera. The total cost of producing such a system is below GBP 3000, which is far cheaper than equivalent existing systems. The design of the portable remote sensing device has eliminated bore sight misalignment errors from the direct geo-referencing process. A new processing technique has been introduced for the data obtained from these low-cost devices, and it is found that using this technique the image can be matched (overlaid) onto Ordnance Survey Master Maps at an accuracy compatible with precision agriculture requirements. The direct geo-referencing has also been improved by introducing an algorithm capable of correcting oblique images directly. This algorithm alters the pixels value, hence it is advised that image analysis is performed before image georectification. The drawback of this research is that the low-cost GPS device experienced bad checksum errors, which resulted in missing data. The Wide Area Augmented System (WAAS) correction could not be employed because the satellites could not be locked onto whilst flying. The best GPS data were obtained from the Garmin eTrex (15 m kinematic and 2 m static) instruments which have a highsensitivity receiver with good lock on capability. The limitation of this GPS device is the inability to effectively receive the P-Code wavelength, which is needed to gain the best accuracy when undertaking differential GPS processing. Pairing the carrier phase L1 with the pseudorange C/A-Code received, in order to determine the image coordinates by the differential technique, is still under investigation. To improve the position accuracy, it is recommended that a GPS base station should be established near the survey area, instead of using a permanent GPS base station established by the Ordnance Survey.