6 resultados para Load effect
em Aston University Research Archive
Resumo:
Multi-agent algorithms inspired by the division of labour in social insects and by markets, are applied to a constrained problem of distributed task allocation. The efficiency (average number of tasks performed), the flexibility (ability to react to changes in the environment), and the sensitivity to load (ability to cope with differing demands) are investigated in both static and dynamic environments. A hybrid algorithm combining both approaches, is shown to exhibit improved efficiency and robustness. We employ nature inspired particle swarm optimisation to obtain optimised parameters for all algorithms in a range of representative environments. Although results are obtained for large population sizes to avoid finite size effects, the influence of population size on the performance is also analysed. From a theoretical point of view, we analyse the causes of efficiency loss, derive theoretical upper bounds for the efficiency, and compare these with the experimental results.
Resumo:
In induction machines the tooth frequency losses due to permeance variation constitute a signif'icant, portion of the total loss. In order to predict and estimate these losses it, is essential to obtain a clear understanding of the no-load distribution of the air gap magnetic field and the magnitude of flux pulsation in both stator and rotor teeth. The existing theories and methods by which the air gap permeance variation in a doubly slotted structure is calculated are either empirical or restricted. The main objective of this thesis is to obtain a detailed analysis of the no-load air gap magnetic field distribution and the effect of air gap geometry on the magnitude and waveform of the tooth flux pulsation. In this thesis a detaiiled theoretical and experimental analysis of flux distribution not only leads to a better understanding of the distribution of no-load losses but also provides theoretical analysis for calculating the losses with greater accuracy
Resumo:
The thesis describes experimental work on sieve trays in an air-water simulator, 2.44 m in diameter. The liquid flow pattern, for flowrates similar to those used in commercial scale distillation, was observed experimentally by water cooling experiments, in which the temperature of the water is measured at over 100 positions over the tray area. The water is cooled by the rising air which is forced through the tray. A heat and mass transfer analogy is drawn whereby the water temperature is mapped to liquid concentration in mass transfer, and the water temperature profiles reveal how liquid channelling may reduce the tray efficiency. The first experiment was to observe the flow of water only over an unperforated tray. With the exception of very low weir loads, the flow separated at the ends of the inlet downcomer. This caused liquid to flow straight across the tray between the downcomers and large circulating regions to be formed in the side regions of the tray. The effect of the air crossflow on the flow pattern was then observed on a sieve tray of 10% free area with 1 mm diameter holes (such as is used in cryogenic distillation). The flow patterns developed on the tray were similar to those produced with water only on the unperforated tray, but at low weir loads the air crossflow prevented separation of the water flow and the associated circulating regions. At higher weir loads, liquid channelling down the centre of the tray and circulation in the side regions occurred. The percentage of the tray occupied by circulating liquid depended upon the velocity of the liquid entering the tray, which was set by the weir load and size of the gap under the inlet downcomer. The water cooling experiments showed that the temperature of the water in a circulating region is much lower than in other parts of the tray, indicating that the driving force for heat transfer is reduced. In a column section where trays (and circulating areas) are mounted on top of each other, the circulating regions will cause air (or vapour) passing through them to have a reduced change in temperature or concentration leading a loss in tray efficiency.
Resumo:
Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.
Resumo:
Objectives: to determine the effect of drugs with anti-cholinergic properties on relevant health outcomes.Design: electronic published and unpublished literature/trial registries were systematically reviewed. Studies evaluating medications with anti-cholinergic activity on cognitive function, delirium, physical function or mortality were eligible.Results: forty-six studies including 60,944 participants were included. Seventy-seven percent of included studies evaluating cognitive function (n = 33) reported a significant decline in cognitive ability with increasing anti-cholinergic load (P < 0.05). Four of five included studies reported no association with delirium and increasing anti-cholinergic drug load (P > 0.05). Five of the eight included studies reported a decline in physical function in users of anti-cholinergics (P < 0.05). Three of nine studies evaluating mortality reported that the use of drugs with anti-cholinergic properties was associated with a trend towards increased mortality, but this was not statistically significant. The methodological quality of the evidence-base ranged from poor to very good.Conclusion: medicines with anti-cholinergic properties have a significant adverse effect on cognitive and physical function, but limited evidence exists for delirium or mortality outcomes. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved.
Resumo:
Experiments were conducted in annealed iridium using pyramidal and spherical indenters over a wide range of load. For a Berkovich pyramidal indenter, the hardness increased with decreasing depth of penetration. However, for spherical indenters, hardness increased with decreasing sphere radius. Based on the number of geometrically necessary dislocations generated during indentation, a theory that takes into account the work hardening differences between pyramidal and spherical indenters is developed to correlate the indentation size effects measured with the two indenters. The experimental results verify the theoretical correlation.