5 resultados para Lens testing

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Drawing on the perceived organizational membership theoretical framework and the social identity view of dissonance theory, I examined in this study the dynamics of the relationship between psychological contract breach and organizational identification. I included group-level transformational and transactional leadership as well as procedural justice in the hypothesized model as key antecedents for organizational membership processes. I further explored the mediating role of psychological contract breach in the relationship between leadership, procedural justice climate, and organizational identification and proposed separateness–connectedness self-schema as an important moderator of the above mediated relationship. Hierarchical linear modeling results from a sample of 864 employees from 162 work units in 10 Greek organizations indicated that employees' perception of psychological contract breach negatively affected their organizational identification. I also found psychological contract breach to mediate the impact of transformational and transactional leadership on organizational identification. Results further provided support for moderated mediation and showed that the indirect effects of transformational and transactional leadership on identification through psychological contract breach were stronger for employees with a low connectedness self-schema.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). Setting - Midland Eye Institute, Solihull, United Kingdom. Design - Cohort study. Methods - Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to -4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). Results - The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to -2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at -1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. Conclusions - The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the performance of an aspheric diffractive multifocal acrylic intraocular lens (IOL), ZMB00 1-Piece Tecnis. Setting: Five sites across Europe. Methods: Fifty-two patients with cataracts (average age 68.5±10.5 years, 35 female) were bilaterally implanted with the aspheric diffractive multifocal IOL after completing a questionnaire regarding their optical visual symptoms, use of visual correction and their visual satisfaction. The questionnaire was completed again 4-6 months after surgery along with measures of uncorrected and best-corrected distance and near visual acuity, under photopic and mesopic lighting, reading ability, defocus curve testing and ocular examination for adverse events. Results: The residual refractive error was 0.01±0.47D with 56% of eyes within ±0.25D and 97% within ±1.0D. Uncorrected visual acuity was 0.02±0.10logMAR at distance and 0.15±0.30 logMAR at near, only reducing to 0.07±0.10logMAR at distance and 0.21±0.25logMAR at near in mesopic conditions.The defocus curve showed a near addition between 2.5-3.0 D allowing a reading acuity of 0.08±0.13 logMAR, with a range of clear vision <0.3 logMAR of ∼4.0 D. The average reading speed was 121.4±30.8 words per minute. Spectacle independence was 100% for distance and 88% for near, with high levels of satisfaction reported. Overall rating of vision without glasses could be explained (r=0.760) by preoperative best-corrected distance acuity, postoperative reading acuity and postoperative uncorrected distance acuity in photopic conditions (p<0.001). Only two minor adverse events occurred. Conclusions: The ZMB00 1-Piece Tecnis multifocal IOL provides a good visual outcome at distance and near with minimal adverse effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.