9 resultados para Laboratory-acquired infection

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To independently evaluate the impact of the second phase of the Health Foundation's Safer Patients Initiative (SPI2) on a range of patient safety measures. Design: A controlled before and after design. Five substudies: survey of staff attitudes; review of case notes from high risk (respiratory) patients in medical wards; review of case notes from surgical patients; indirect evaluation of hand hygiene by measuring hospital use of handwashing materials; measurement of outcomes (adverse events, mortality among high risk patients admitted to medical wards, patients' satisfaction, mortality in intensive care, rates of hospital acquired infection). Setting: NHS hospitals in England. Participants: Nine hospitals participating in SPI2 and nine matched control hospitals. Intervention The SPI2 intervention was similar to the SPI1, with somewhat modified goals, a slightly longer intervention period, and a smaller budget per hospital. Results: One of the scores (organisational climate) showed a significant (P=0.009) difference in rate of change over time, which favoured the control hospitals, though the difference was only 0.07 points on a five point scale. Results of the explicit case note reviews of high risk medical patients showed that certain practices improved over time in both control and SPI2 hospitals (and none deteriorated), but there were no significant differences between control and SPI2 hospitals. Monitoring of vital signs improved across control and SPI2 sites. This temporal effect was significant for monitoring the respiratory rate at both the six hour (adjusted odds ratio 2.1, 99% confidence interval 1.0 to 4.3; P=0.010) and 12 hour (2.4, 1.1 to 5.0; P=0.002) periods after admission. There was no significant effect of SPI for any of the measures of vital signs. Use of a recommended system for scoring the severity of pneumonia improved from 1.9% (1/52) to 21.4% (12/56) of control and from 2.0% (1/50) to 41.7% (25/60) of SPI2 patients. This temporal change was significant (7.3, 1.4 to 37.7; P=0.002), but the difference in difference was not significant (2.1, 0.4 to 11.1; P=0.236). There were no notable or significant changes in the pattern of prescribing errors, either over time or between control and SPI2 hospitals. Two items of medical history taking (exercise tolerance and occupation) showed significant improvement over time, across both control and SPI2 hospitals, but no additional SPI2 effect. The holistic review showed no significant changes in error rates either over time or between control and SPI2 hospitals. The explicit case note review of perioperative care showed that adherence rates for two of the four perioperative standards targeted by SPI2 were already good at baseline, exceeding 94% for antibiotic prophylaxis and 98% for deep vein thrombosis prophylaxis. Intraoperative monitoring of temperature improved over time in both groups, but this was not significant (1.8, 0.4 to 7.6; P=0.279), and there were no additional effects of SPI2. A dramatic rise in consumption of soap and alcohol hand rub was similar in control and SPI2 hospitals (P=0.760 and P=0.889, respectively), as was the corresponding decrease in rates of Clostridium difficile and meticillin resistant Staphylococcus aureus infection (P=0.652 and P=0.693, respectively). Mortality rates of medical patients included in the case note reviews in control hospitals increased from 17.3% (42/243) to 21.4% (24/112), while in SPI2 hospitals they fell from 10.3% (24/233) to 6.1% (7/114) (P=0.043). Fewer than 8% of deaths were classed as avoidable; changes in proportions could not explain the divergence of overall death rates between control and SPI2 hospitals. There was no significant difference in the rate of change in mortality in intensive care. Patients' satisfaction improved in both control and SPI2 hospitals on all dimensions, but again there were no significant changes between the two groups of hospitals. Conclusions: Many aspects of care are already good or improving across the NHS in England, suggesting considerable improvements in quality across the board. These improvements are probably due to contemporaneous policy activities relating to patient safety, including those with features similar to the SPI, and the emergence of professional consensus on some clinical processes. This phenomenon might have attenuated the incremental effect of the SPI, making it difficult to detect. Alternatively, the full impact of the SPI might be observable only in the longer term. The conclusion of this study could have been different if concurrent controls had not been used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To analyze the recent epidemiology of methicillin-resistant Staphylococcus aureus (MRSA) bacteremia in a UK tertiary referral center. Methods: We collected epidemiological and laboratory data on all cases of MRSA bacteremia from September 1, 2005 to December 31, 2007. Results: There were 195 clinically significant episodes. Most were hospital-acquired. Only one episode occurred in patients without a history of hospital admission in the previous 12 months. An intravascular device was the most common focus of infection (37%), with no identifiable source found in 35% of episodes. Twenty-eight percent of patients died within 30 days of bacteremia. Mortality was significantly higher in the absence of an identifiable focus. Failure to include an antibiotic active against MRSA in the empirical treatment was only significantly associated with death in patients showing signs of hemodynamic instability (p < 0.001). No isolates had a minimum inhibitory concentration to vancomycin above 1.5. mg/l and no heteroresistance to glycopeptide antibiotics (heteroresistant vancomycin-intermediate Staphylococcus aureus; hVISA) was detected. All isolates were sensitive to daptomycin, tigecycline, and linezolid. Conclusions: Despite improvement in infection control measures, medical devices remain the most common source of infection. Inappropriate empirical antibiotic usage is associated with a poor outcome in patients with signs of severe sepsis. Susceptibility to glycopeptides and newer antibiotics remains good. © 2010 International Society for Infectious Diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There has been a persistent increase in the number of meticillin-resistant Staphylococcus aureus (MRSA) and meticillin-susceptible Staphylococcus aureus (MSSA) bacteraemia in the UK. This prospective study included 147 episodes of S. aureus bacteraemia in 139 patients over a 14 month period, from 1 November 2001 to 31 December 2002. Eighty-seven (59%) episodes in 84 patients and 60 (41%) in 56 patients were due to MRSA and MSSA, respectively. An intra-vascular device (29, 33%) and a soft-tissue (15, 25%) source were the commonest identifiable foci for bacteraemia in the MRSA and MSSA groups, respectively. Attributable mortality in the MRSA group was higher than the MSSA group (33% vs 16%; P = 0.03) but there was no statistical difference for either attributable (P = 0.35) or crude (P = 0.39) mortality between the two groups, when adjusted for age, respiratory focus and inappropriate antibiotic therapy. A respiratory source (P = 0.02) and inappropriate antibiotic therapy (P = 0.02) were associated with attributable mortality in the MRSA group whereas advanced age was the only risk factor (P = 0.02) in the MSSA group. The present study shows that S. aureus bacteraemia continues to be a serious infection mostly affecting the elderly and emphasizes the need for improved strategy in the control and management of this condition. © 2006 The Hospital Infection Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chronic experimental lung infection in rats was induced by intratracheal inoculation of agar beads containing Pseudomonas aeruginosa. Bacteria were recovered directly without subculture from the lungs of rats at 14 days post-infection and the outer membrane (OM) antigens were studied. The results indicated that bacteria grew under iron-restricted conditions as revealed by the expression of several iron-regulated membrane proteins (IRMPs) which could also be observed when the isolate was grown under iron-depleted conditions in laboratory media. The antibody response to P. aeruginosa OM protein antigens was investigated by immunoblotting with serum and lung fluid from infected rats. These fluids contained antibodies to all the major OM proteins, including the IRMPs, and protein H1. Results obtained using immunoblotting and enzyme-linked immunosorbent assay indicated that lipopolysaccharide (LPS) was the major antigen recognised by antibodies in sera from infected rats. The animal model was used to follow the development of the immune response to P. aeruginosa protein and LPS antigens. Immunoblotting was used to investigate the antigens recognised by antibodies in sequential serum samples. An antibody response to the IRMPs and OM proteins D, E, G and H1 and alao to rough LPS was detected as early as 4 days post-infection. Results obtained using immunoblotting and crossed immunoelectrophoresis techniques indicated that there was a progressive increase in the number of P. aeruginosa antigens recognised by antibodies in these sera. Both iron and magnesium depletion influenced protein H1 production. Antibodies in sera from patients with infections due to P. aeruginosa reacted with this antigen. Results obtained using quantitative gas-liquid chromatographic analysis indicated that growth phase and magnesium and iron depletion also affected the amount of LPS fatty acids, produced by P. aeruginosa. The silver stained SDS-polyacrylamide gels of proteinase K digested whole cell lysates of P. aeruginosa indicated that the O-antigen and core LPS were both affected by growth phase and specific nutrient depletion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Between January 2005 and December 2005, 199 meticillin-resistant Staphylococcus aureus (MRSA) isolates were obtained from nonhospitalised patients presenting skin and soft tissue infections to local general practitioners. The study area incorporated 57 surgeries from three Primary Care Trusts in the Lichfield, Tamworth, Burntwood, North and East Birmingham regions of Central England, UK. Following antibiotic susceptibility testing, pulsed-field gel electrophoresis, Panton-Valentine leukocidin gene detection and SCCmec element assignment, 95% of the isolates were shown to be related to hospital epidemic strains EMRSA-15 and EMRSA-16. In total 87% of the isolate population harboured SCCmec IV, 9% had SCCmec II and 4% were identified as carrying novel SCCmec IIIa-mecI. When mapped to patient home postcode, a diverse distribution of isolates harbouring SCCmec II and SCCmec IV was observed; however, the majority of isolates harbouring SCCmec IIIa-mecI were from patients residing in the north-west of the study region, highlighting a possible localised clonal group. Transmission of MRSA from the hospital setting into the surrounding community population, as demonstrated by this study, warrants the need for targeted patient screening and decolonisation in both the clinical and community environments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intravascular catheters are one of the main causes of bacteraemia and septicaemia in hospitalised patients and continue to be associated with a significant morbidity and mortality. Two main types of infections occur, they can be either localised at the catheter insertion site of systemic with a septicaemia. The clinical parameters related to these infections are presented. The laboratory diagnosis of these infections is also extensively reviewed and recommendations are made as to the most appropriate diagnostic method to be used. © 2005 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis of prosthetic joint infection and its differentiation from aseptic loosening remains problematic. The definitive laboratory diagnostic test is the recovery of identical infectious agents from multiple intraoperative tissue samples; however, interpretation of positive cultures is often complex as infection is frequently associated with low numbers of commensal microorganisms, in particular the coagulase-negative staphylococci (CNS). In this investigation, the value of serum procalcitonin (PCT), interleukin-6 (IL-6) and soluble intercellular adhesion molecule-1 (sICAM-1) as predictors of infection in revision hip replacement surgery is assessed. Furthermore, the diagnostic value of serum IgG to short-chain exocellular lipoteichoic acid (sce-LTA) is assessed in patients with infection due to CNS. Presurgical levels of conventional serum markers of infection including C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and white blood cell count (WBC) is also established. Forty-six patients undergoing revision hip surgery were recruited with a presumptive clinical diagnosis of either septic (16 patients) or aseptic loosening (30 patients). The diagnosis was confirmed microbiologically and levels of serum markers were determined. Serum levels of IL-6 and sICAM-1 were significantly raised in patients with septic loosening (P=0.001 and P=0.0002, respectively). Serum IgG to sce-LTA was elevated in three out of four patients with infection due to CNS. In contrast, PCT was not found to be of value in differentiating septic and aseptic loosening. Furthermore, CRP, ESR and WBC were significantly higher (P=0.0001, P=0.0001 and P=0.003, respectively) in patients with septic loosening. Serum levels of IL-6, sICAM-1 and IgG to sce-LTA may provide additional information to facilitate the diagnosis of prosthetic joint infection.