13 resultados para LIGHT-CURING METHODS

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Different types of microstructures including microchannels and microslots were made in optical fibers using femtosecond laser inscription and chemical etching. Integrated with UV-inscribed fiber Bragg gratings, these microstructures have miniature, robustness and high sensitivity features and have been used to implement novel devices for various sensing applications. The fiber microchannels were used to detect the refractive index change of liquid presenting sensitivities up to 7.4 nm/refractive index unit (RIU) and 166.7 dB/RIU based on wavelength and power detection, respectively. A microslot-in-fiber based liquid core waveguide as a refractometer has been proposed and the device was used to measure refractive index, and a sensitivity up to 945 nm/RIU (10-6/pm) was obtained. By filling epoxy in the microslot and subsequent UV light curing, a hybrid waveguide grating structure with polymer core and glass cladding was fabricated. The obtained device was highly thermal responsive, demonstrating a linear coefficient of 211 pm/°C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Different types of microstructures including microchannels and microslots were made in optical fibers using femtosecond laser inscription and chemical etching. Integrated with UV-inscribed fiber Bragg gratings, these microstructures have miniature, robustness and high sensitivity features and have been used to implement novel devices for various sensing applications. The fiber microchannels were used to detect the refractive index change of liquid presenting sensitivities up to 7.4 nm/refractive index unit (RIU) and 166.7 dB/RIU based on wavelength and power detection, respectively. A microslot-in-fiber based liquid core waveguide as a refractometer has been proposed and the device was used to measure refractive index, and a sensitivity up to 945 nm/RIU (10-6/pm) was obtained. By filling epoxy in the microslot and subsequent UV light curing, a hybrid waveguide grating structure with polymer core and glass cladding was fabricated. The obtained device was highly thermal responsive, demonstrating a linear coefficient of 211 pm/°C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study examines the cultural value orientations of employees working in major industrial and commercial centers of six ex-communist Central Eastern European Countries (CEECs) and Euro-Asian countries, in particular the former Soviet Republics (FSRs). The analysis is based on a questionnaire survey administered with 1052 respondents. The study tests a number of hypotheses regarding the cultural orientations of the sample populations, using gender as the core variable. The study reports cultural dimensions on which the female respondents clearly differ from their male counterparts, and there is more cultural homogeneity among males than among females within the CEECs and FSRs. Furthermore, the findings show similar cultural patterns emerging between the Czech Republic, former East Germany (FEG), and Poland on the one hand and Georgia and Uzbekistan on the other, whereas Russia culturally stands between the two groups. The research also highlights the basis of cultural aspects from which both national and managerial cultures of each research country are emerging. It brings to light the methods employed by management toward human resources in these countries, and also identifies key issues for overseas operators currently undertaking a business or planning to establish one in these countries. © 2011 Taylor & Francis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The synthesis of a novel heterocyclic–telechelic polymer, α,ω-oxetanyl-telechelic poly(3-nitratomethyl-3-methyl oxetane), is described. Infrared spectroscopy (IR), gel permeation chromatography (GPC), and nuclear magnetic resonance (NMR) spectroscopy have been used to confirm the successful synthesis, demonstrating the presence of the telechelic-oxetanyl moieties. Synthesis of the terminal functionalities has been achieved via displacement of nitrato groups, in a manner similar to that employed with other leaving groups such as azido, bromo, and nitro, initiated by nucleophiles. In the present case, displacement occurs on the ends of a nitrato-functionalized polymer driven by the formation of sodium nitrate, which is supported by the polar aprotic solvent N,N-dimethyl formamide. The formation of an alkoxide at the polymer chain ends is favored and allows internal back-biting to the nearest carbon bearing the nitrato group, intrinsically in an SN2(i) reaction, leading to α,ω-oxetanyl functionalization. The telechelic-oxetanyl moieties have the potential to be cross-linked by chemical (e.g., acidic) or radiative (e.g., ultraviolet) curing methods without the use of high temperatures, usually below 100°C. This type of material was designed for future use as a contraband simulant, whereby it would form the predominant constituent of elastomeric composites comprising rubbery polymer with small quantities of solids, typically crystals of contraband substances, such as explosives or narcotics. This method also provides an alternative approach to ring closure and synthesis of heterocycles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Serum concentrations of polyclonal free light chains (FLC) represent the activity of the adaptive immune system. This study assessed the relationship between polyclonal FLC and the established marker of innate immunity, C-reactive protein (CRP), in chronic and acute disease. Methods: We utilized four cross-sectional chronic disease patient cohorts: chronic kidney disease (CKD), diabetes, vasculitis and kidney transplantation; and a longitudinal intensive care case series to assess the kinetics of production in acute disease. Results: There was a weak association between polyclonal FLC and high-sensitivity CRP (hs-CRP) in the study cohorts. A longitudinal assessment in acute disease showed a gradual increase in FLC concentrations over time, often when CRP levels were falling, demonstrating clear differences in the response kinetics of CRP and FLC in this setting. Conclusion: Polyclonal FLC and hs-CRP provide independent information as to inflammatory status. Prospective studies are now required to assess the utility of hs-CRP and polyclonal FLC in combination for risk stratification in disease populations. © 2013 John Wiley & Sons Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Elevated polyclonal serum immunoglobulin free light chains (FLCs; combined FLCκ+FLCλ [cFLC]) are associated with adverse clinical outcomes and increased mortality; we investigated cFLC and cardiovascular disease (CVD) events in type 2 diabetes. RESEARCH DESIGN AND METHODS: In a cohort study of 352 south Asian patients with type 2 diabetes, serum cFLC, high-sensitivity C-reactive protein (hsCRP), and standard biochemistry were measured. CVD events over 2 years were recorded and assessed usingmultiple logistic regression. RESULTS: cFLC levels were elevated significantly in 29 of 352 (8%) patients with CVD events during 2 years of follow-up (50.7 vs. 42.8mg/L; P = 0.004). Inmultivariate analysis, elevated cFLC (>57.2 mg/L) was associated with CVD outcomes (odds ratio 3.3 [95% CI 1.3-8.2]; P = 0.012) and remained significant after adjusting for age, albumin-to-creatinine ratio, diabetes duration, or treatment. CONCLUSIONS: cFLC elevation is a novel marker for CVD outcomes in type 2 diabetes that warrants further investigation. © 2014 by the American Diabetes Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Environmental conditions early in life may imprint the circadian system and influence response to environmental signals later in life. We previously determined that a large springtime increase in solar insolation at the onset location was associated with a younger age of onset of bipolar disorder, especially with a family history of mood disorders. This study investigated whether the hours of daylight at the birth location affected this association. Methods: Data collected previously at 36 collection sites from 23 countries were available for 3896 patients with bipolar I disorder, born between latitudes of 1.4N and 70.7N, and 1.2S and 41.3S. Hours of daylight variables for the birth location were added to a base model to assess the relation between the age of onset and solar insolation. Results: More hours of daylight at the birth location during early life was associated with an older age of onset, suggesting reduced vulnerability to the future circadian challenge of the springtime increase in solar insolation at the onset location. Addition of the minimum of the average monthly hours of daylight during the first 3 months of life improved the base model, with a significant positive relationship to age of onset. Coefficients for all other variables remained stable, significant and consistent with the base model. Conclusions: Light exposure during early life may have important consequences for those who are susceptible to bipolar disorder, especially at latitudes with little natural light in winter. This study indirectly supports the concept that early life exposure to light may affect the long term adaptability to respond to a circadian challenge later in life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The combination of the third-order optical nonlinearity with chromatic dispersion in optical fibers offers an extremely rich variety of possibilities for tailoring the temporal and spectral content of a light signal, depending on the regime of dispersion that is used. Here, we review recent progress on the use of third-order nonlinear processes in optical fibers for pulse shaping in the temporal and spectral domains. Various examples of practical significance will be discussed, spanning fields from the generation of specialized temporal waveforms to the generation of ultrashort pulses, and to stable continuum generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To to evaluate the benefit of bilinear and linear fitting to characterize the retinal vessel dilation to flicker light stimulation for the purpose of risk stratification in cardiovascular disease. Methods: Forty-five patients (15 with coronary artery disease (CAD), 15 with Diabetes Mellitus (DM) and 15 with CAD and DM) all underwent contact tonometry, digital blood pressure measurement, fundus photography, retinal vessel oximetry, static retinal vessel analysis and continous retinal diameter assessment using the retinal vessel analyser (and flicker light provocation). In addition we measured blood glucose (HbA1c) and keratinin levels in DM patients. Results: With increased severity of cardiovascular disease a more linear reaction profile of retinal arteriolar diameter to flicker light provocation can be observed. Conclusion: Absolute values of vessel dilation provide only limited information on the state of retinal arteriolar dilatory response to flicker light. The approach of bilinear fitting takes into account the immediate response to flicker light provocation as well as the maintained dilatory capacity during prolonged stimulation. Individuals with cardiovascular disease however show a largely linear reaction profile indicating an impairment of the initial rapid dilatory response as usually observed in healty individuals

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine the response of retinal vessels to differing durations of flicker light (FL) sitmulation. Methods: We recorded retinal arterial and venous vessel dilation to 12.5 Hz flicker light provocation (Retinal Vessel Analyzer, Imedos Systems) of varying duration (5, 7, 10 and 20 seconds) in twelve healthy young individuals (age range 26-45 yrs). All participants underwent a full ocular examination including intraocular pressure and blood pressure measurements. Results: Maximum dilation (MD) did not show a significant dependence on flicker duration in arteries whereas maximum constriction (MC) did. However, in veins MD significantly increased with flicker duration. Approximately 80-90% of MD in arteries is reached within 10 seconds of flicker light stimulation. Conclusions: The vast majority of arterial dilatory capacity is reached within 10 seconds of flicker light stimulation even though venous dilation continues strongly. Since the MC of arteries shows a significant dependence on flicker duration measurements at two different durations can provide more information about the retinal vascular system than at a single flicker duration alone.