3 resultados para L-Strip Fed Microstrip Antennas

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis provides the first detailed study of maximal oxygen consumption of turbot on a fish farm over a range of fish sizes and temperatures. Also provided is a study of the diets used in turbot farming and the development of a diet that contains no fresh fish. A detailed study of previous research on flatfish nutrition, identified fresh fish, sprat in particular, as the optimum diet for turbot farming. A series of experiments was undertaken that confirmed this and also identified one possible explanation for the optimum performance of sprat, as a function of high non-protein energy ratios in sprat. This factor was exploited in the production of a diet containing no fresh fish and which produced superior results to diets containing fresh fish; the optimum level of lipid in the diet was determined as 18%. The study of oxygen consumption was on fully-fed fish so that maximum demand could be quantified. Continuous monitoring of tank water oxygen levels enabled the calculation of the Specific Dynamic Action (SDA) effect in turbot and the relation of it to dietary energy. Variation of SDA with the dietary energy profile was identified as a contributing factor to differential fish growth on various diets. Finally, the implications of this work to fish farming were considered. Economic appraisal and comparison of the diets routinely used in turbot farming identified that the diet developed as a result of this work, ie the diet containing no fresh fish protein, was more cost effective on the basis of the production of one tonne of turbot. The study of oxygen consumption enables water supply to be calculated for any fish size between 1g and 1000g between the temperatures of 7® C and 16® C. The quantification of SDA enables correct adjustment of oxygen flows according to the feeding status of the fish.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a new open-winding control strategy is proposed for a brushless doubly fed reluctance generator (BDFRG) used for stand-alone wind turbine or ship generators. The BDFRG is characterized with two windings on the stator: a power winding and a control winding. The control winding is fed with dual two-level three-phase converters, and a vector control scheme based on space vector pulsewidth modulation is designed. Compared with traditional three-level inverter systems, the dc-link voltage and the voltage rating of power devices in the proposed system are reduced by 50% while still greatly improving the reliability, redundancy, and fault tolerance of the proposed system by increasing the switching modes. Its performance is evaluated by simulation in MATLAB/Simulink and an experimental study on a 42-kW prototype machine.