11 resultados para Islanded network operation

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic asset rating (DAR) is one of the number of techniques that could be used to facilitate low carbon electricity network operation. Previous work has looked at this technique from an asset perspective. This paper focuses, instead, from a network perspective by proposing a dynamic network rating (DNR) approach. The models available for use with DAR are discussed and compared using measured load and weather data from a trial network area within Milton Keynes in the central area of the U.K. This paper then uses the most appropriate model to investigate, through a network case study, the potential gains in dynamic rating compared to static rating for the different network assets - transformers, overhead lines, and cables. This will inform the network operator of the potential DNR gains on an 11-kV network with all assets present and highlight the limiting assets within each season.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic asset rating is one of a number of techniques that could be used to facilitate low carbon electricity network operation. This paper focusses on distribution level transformer dynamic rating under this context. The models available for use with dynamic asset rating are discussed and compared using measured load and weather conditions from a trial Network area within Milton Keynes. The paper then uses the most appropriate model to investigate, through simulation, the potential gains in dynamic rating compared to static rating under two transformer cooling methods to understand the potential gain to the Network Operator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Future network operation will be influenced by business and ownership models and the regulatory environment as future superfast and flexible broadband networks emerge. This paper discusses the issues affecting operators and network operations as network evolution progresses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper discusses the potentiality of reconfiguring distribution networks into islanded Microgrids to reduce the network infrastructure reinforcement requirement and incorporate various dispersed energy resources. The major challenge would be properly breaking down the network and its resultant protection and automation system changes. A reconfiguration method is proposed based on allocation of distributed generation resources to fulfil this purpose, with a heuristic algorithm. Cost/reliability data is required for the next stage tasks to realise a case study of a particular network.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Automatically generating maps of a measured variable of interest can be problematic. In this work we focus on the monitoring network context where observations are collected and reported by a network of sensors, and are then transformed into interpolated maps for use in decision making. Using traditional geostatistical methods, estimating the covariance structure of data collected in an emergency situation can be difficult. Variogram determination, whether by method-of-moment estimators or by maximum likelihood, is very sensitive to extreme values. Even when a monitoring network is in a routine mode of operation, sensors can sporadically malfunction and report extreme values. If this extreme data destabilises the model, causing the covariance structure of the observed data to be incorrectly estimated, the generated maps will be of little value, and the uncertainty estimates in particular will be misleading. Marchant and Lark [2007] propose a REML estimator for the covariance, which is shown to work on small data sets with a manual selection of the damping parameter in the robust likelihood. We show how this can be extended to allow treatment of large data sets together with an automated approach to all parameter estimation. The projected process kriging framework of Ingram et al. [2007] is extended to allow the use of robust likelihood functions, including the two component Gaussian and the Huber function. We show how our algorithm is further refined to reduce the computational complexity while at the same time minimising any loss of information. To show the benefits of this method, we use data collected from radiation monitoring networks across Europe. We compare our results to those obtained from traditional kriging methodologies and include comparisons with Box-Cox transformations of the data. We discuss the issue of whether to treat or ignore extreme values, making the distinction between the robust methods which ignore outliers and transformation methods which treat them as part of the (transformed) process. Using a case study, based on an extreme radiological events over a large area, we show how radiation data collected from monitoring networks can be analysed automatically and then used to generate reliable maps to inform decision making. We show the limitations of the methods and discuss potential extensions to remedy these.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Relationships between organizations can be characterized by cooperation, conflict, and change. In this dissertation we study cooperation between organizations by investigating how norms in relationships can enhance innovativeness and subsequently impact relationship performance. We do so by incorporating both beneficial aspects of long term relationships as well as “dark side” factors that may decrease innovativeness. This provides a balanced assessment of the factors increasing and decreasing the performance of relationships. Next, we study conflict between organizations by taking a network view on conflict which helps explain why organizations react to conflict. We find stakeholders to have an effect on channel conflict responsiveness. Finally we study change by means of an organization’s ability to successfully add an Internet channel to their distribution system in order to sell its products or services directly to the end-user. We find that an Internet channel is best implemented by organizations that are flexible and we identify several circumstances under which this flexibility is highest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis describes the investigation of an adaptive method of attenuation control for digital speech signals in an analogue-digital environment and its effects on the transmission performance of a national telecommunication network. The first part gives the design of a digital automatic gain control, able to operate upon a P.C.M. signal in its companded form and whose operation is based upon the counting of peaks of the digital speech signal above certain threshold levels. A study was ma.de of a digital automatic gain control (d.a.g.c.) in open-loop configuration and closed-loop configuration. The former was adopted as the means for carrying out the automatic control of attenuation. It was simulated and tested, both objectively and subjectively. The final part is the assessment of the effects on telephone connections of a d.a.g.c. that introduces gains of 6 dB or 12 dB. This work used a Telephone Connection Assessment Model developed at The University of Aston in Birmingham. The subjective tests showed that the d.a.g.c. gives advantage for listeners when the speech level is very low. The benefit is not great when speech is only a little quieter than preferred. The assessment showed that, when a standard British Telecom earphone is used, insertion of gain is desirable if speech voltage across the earphone terminals is below an upper limit of -38 dBV. People commented upon the presence of an adaptive-like effect during the tests. This could be the reason why they voted against the insertion of gain at level only little quieter than preferred, when they may otherwise have judged it to be desirable. A telephone connection with a d.a.g.c. in has a degree of difficulty less than half of that without it. The score Excellent plus Good is 10-30% greater.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - The rise of recent product recalls reveals that manufacturing firms are particularly vulnerable to product quality and safety where goods and materials have been sourced globally. The purpose of this paper is to explore the issues of quality and safety problems in global supply networks, and introduce a supply chain risk management (SCRM) framework to reduce the quality risk. Design/methodology/approach - A conceptual SCRM framework for mitigating quality risk is developed. In addition, four SCRM treatment practices are proposed by consolidating the empirical literature in the operations management and supply chain management areas. The general feasibility was discussed based on literature. Findings - The research has identified the root causes of the recent product recalls and a series of product harm scandals ranging from automobiles to unsafe toys. Supply chains are extended by outsourcing and stretched by globalization, which greatly increase the complexity of supply networks and decrease the visibility in risk and operation processes. Originality/value - The paper identifies four SCRM practices, and proposes two distinct antecedents that can prompt the effectiveness of SCRM. © 2011 Emerald Group Publishing Limited. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computerised production control developments have concentrated on Manufacturing Resources Planning (MRP II) systems. The literature suggests however, that despite the massive investment in hardware, software and management education, successful implementation of such systems in manufacturing industries has proved difficult. This thesis reviews the development of production planning and control systems, in particular, investigates the causes of failures in implementing MRP/MRP II systems in industrial environments and argues that the centralised and top-down planning structure, as well as the routine operational methodology of such systems, is inherently prone to failure. The thesis reviews the control benefits of cellular manufacturing systems but concludes that in more dynamic manufacturing environments, techniques such as Kanban are inappropriate. The basic shortcomings of MRP II systems are highlighted and a new enhanced operational methodology based on distributed planning and control principles is introduced. Distributed Manufacturing Resources Planning (DMRP), was developed as a capacity sensitive production planning and control solution for cellular manufacturing environments. The system utilises cell based, independently operated MRP II systems, integrated into a plant-wide control system through a Local Area Network. The potential benefits of adopting the system in industrial environments is discussed and the results of computer simulation experiments to compare the performance of the DMRP system against the conventional MRP II systems presented. DMRP methodology is shown to offer significant potential advantages which include ease of implementation, cost effectiveness, capacity sensitivity, shorter manufacturing lead times, lower working in progress levels and improved customer service.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cost and limited flexibility of traditional approaches to 11kV network reinforcement threatens to constrain the uptake of low carbon technologies. Ofgem has released £500m of funding for DNOs to trial innovative techniques and share the learning with the rest of the industry. One of the techniques under study is the addition of Energy Storage at key substations to the network to help with peak load lopping. This paper looks in detail at the sizing algorithm for use in the assessment of alternatives to traditional reinforcement and investigates a method of sizing a battery for use on a Network taking into account load growth, capacity fade and battery lifecycle issues. A further complication to the analysis is the method of operation of the battery system and how this affects the Depth of Discharge (DoD). The proposed method is being trialled on an area of 11kV network in Milton Keynes Central area and the simulation results are presented in this paper.