10 resultados para Interactive virtual reality
em Aston University Research Archive
Resumo:
ABSTRACT: Purpose. Virtual reality devices, including virtual reality head-mounted displays, are becoming increasingly accessible to the general public as technological advances lead to reduced costs. However, there are numerous reports that adverse effects such as ocular discomfort and headache are associated with these devices. To investigate these adverse effects, questionnaires that have been specifically designed for other purposes such as investigating motion sickness have often been used. The primary purpose of this study was to develop a standard questionnaire for use in investigating symptoms that result from virtual reality viewing. In addition, symptom duration and whether priming subjects elevates symptom ratings were also investigated. Methods. A list of the most frequently reported symptoms following virtual reality viewing was determined from previously published studies and used as the basis for a pilot questionnaire. The pilot questionnaire, which consisted of 12 nonocular and 11 ocular symptoms, was administered to two groups of eight subjects. One group was primed by having them complete the questionnaire before immersion; the other group completed the questionnaire postviewing only. Postviewing testing was carried out immediately after viewing and then at 2-min intervals for a further 10 min. Results. Priming subjects did not elevate symptom ratings; therefore, the data were pooled and 16 symptoms were found to increase significantly. The majority of symptoms dissipated rapidly, within 6 min after viewing. Frequency of endorsement data showed that approximately half of the symptoms on the pilot questionnaire could be discarded because <20% of subjects experienced them. Conclusions. Symptom questionnaires to investigate virtual reality viewing can be administered before viewing, without biasing the findings, allowing calculation of the amount of change from pre- to postviewing. However, symptoms dissipate rapidly and assessment of symptoms needs to occur in the first 5 min postviewing. Thirteen symptom questions, eight nonocular and five ocular, were determined to be useful for a questionnaire specifically related to virtual reality viewing using a head-mounted display.
Resumo:
I was recently part of a small committee looking at higher qualifications in contact lens practice and the discussion turned to future technologies. There was mention of different materials and different applications of contact lenses. Drug delivery with contact lenses was discussed as this has been talked about in the literature for a while. The first paper I could find that talked about using contact lenses for drug delivery dates back over 40 years. There was a review paper in CLAE in 2008 that looked specifically at this too [1]. However, where are these products? Why are we not seeing them in the market place? Maybe the technology is not quite there yet, or maybe patents are prohibiting usage or maybe the market is not big enough to develop such products? We do have lenses on the market with slow release of lubricating agents but not therapeutic agents used for ocular or systemic conditions. Contact lenses with pathogen detectors may be part of our contact lens armoury of the future and again we can already see papers in the literature that have trialled this technology for glucose monitoring in diabetics or lactate concentration in the tear film. Future contact lenses may incorporate better optics based on aberration control and we see this starting to emerge with aspheric designs designed to minimise spherical aberration. Irregular corneas can be fitted with topography based designs and again this technology exists and is being used by some manufacturers in their designs already. Moreover, the topography based fitting of irregular corneas is certainly something we see a lot of today and CLAE has seen many articles related to this over the last decade or so. What about further into the future? Well one interesting area must the 3-dimensional contact lenses, or contact lenses with electronic devices built in that simulate a display screen. A little like the virtual display spectacles that are already sold by electronics companies. It does not take much of a stretch of the imagination to see a large electronic company taking this technology on and making it viable. Will we see people on the train watching movies on these electronic virtual reality contact lenses? I think we will, but when is harder to know.
Resumo:
Editorial: The 2015 BCLA annual conference was another fantastic affair. It was the first time the conference was held in the beautiful city of Liverpool. The venue was great and the programme was excellent. The venue overlooked the River Mersey and many of the hotels were local boutique hotels. I stayed in one which was formerly the offices of White Star Liners—where the RMS Titanic was originally registered. The hotel decor was consistent with its historic significance. The BCLA gala dinner was held in the hugely impressive Anglican Cathedral with entertainment from a Beatles tribute band. That will certainly be a hard act to follow at the next conference in 2017. Brian Tompkins took the reigns as the new BCLA president. Professor Fiona Stapleton was the recipient of the BCLA Gold Medal Award. The winner of the poster competition was Dorota Szczesna-Iskander with a poster entitled ‘Dry Contact lens poor wettability and visual performance’. Second place was Renee Reeder with her poster entitled ‘Abnormal Rosacea as a differential diagnosis in corneal scarring’. And third place was Maria Jesus Gonzalez-Garcia with her poster entitled ‘Dry Effect of the Environmental Conditions on Tear Inflammatory Mediators Concentration in Contact Lens Wearers’. The photographic competition winner was Professor Wolfgang Sickenberger from Jena in Germany. The Editorial Panel of CLAE met at the BCLA conference for their first biannual meeting. The journal metrics were discussed. In terms of number of submissions of new papers CLAE seems to have plateaued after seeing a rapid growth in the number of submissions over the last few years. The increase over the last few years could be attributed to the fact that CLAE was awarded an impact factor for the first time in 2012. This year it seems that impact factors across nearly all ophthalmic related journals has dropped. This could in part be due to the fact that last year was a ‘Research Exercise Framework (REF) year for UK universities, where they are judged on quality of their research output. The next REF is in 2020 so we may see changes nearing that time. Looking at article downloads, there seems to be a continued rise in figures. Currently CLAE attracts around 85,000 downloads per year (this is an increase of around 10,000 per year for the last few years) and the 2015 prediction is 120,000! With this in mind and with other contributing factors too, the BCLA has decided to move to online delivery of CLAE to its members starting from issue 5 of 2015. Some members do like to flick through the pages of a hard copy of the journal so members will still have the option of receiving a hard copy through the post but the default journal delivery method will now be online. The BCLA office will send various alerts and content details to members email addresses. To access CLAE online you will need to log in via the BCLA web page, currently you then click on ‘Resources’ and then under ‘Free and Discounted Publications’ you will see CLAE. This actually takes you to CLAE’s own webpage (www.contactlensjournal.com) but you need to log in via the BCLA web page. The BCLA plans to change these weblinks so that from the BCLA web page you can link to the journal website much more easily and you have the choice of going directly into the general website for CLAE or straight to the current issue. In 2016 you will see an even easier way of accessing CLAE online as the BCLA will launch a CLAE application for mobile devices where the journal can be downloaded as a ‘flick-book’. This is a great way of bringing CLAE into the modern era where people access their information in newer ways. For many the BCLA conference was part of a very busy conference week as it was preceded by the International Association of Contact Lens Educators’ (IACLE) Third World Congress, held in Manchester on the 4 days before the BCLA conference. The first and second IACE World Congresses were held in Waterloo, Canada in 1994 and 2000 respectively and hosted by Professor Des Fonn. Professor Fonn was the recipient of the first ever IACLE lifetime achievement award. The Third IACLE World Congress saw more than 100 contact lens educators and industry representatives from around 30 countries gather in the UK for the four-day event, hosted by The University of Manchester. Delegates gained hands-on experience of innovations in teaching, such as learning delivery systems, the use of iPads in the classroom and for creating ePub content, and augmented and virtual reality technologies. IACLE members around the world also took part via a live online broadcast. The Third IACLE World Congress was made possible by the generous support of Sponsors Alcon, CooperVision and Johnson & Johnson Vision Care., for more information look at the IACLE web page (www.iacle.org).