15 resultados para In-vehicle system
em Aston University Research Archive
Resumo:
Frequency, time and places of charging and discharging have critical impact on the Quality of Experience (QoE) of using Electric Vehicles (EVs). EV charging and discharging scheduling schemes should consider both the QoE of using EV and the load capacity of the power grid. In this paper, we design a traveling plan-aware scheduling scheme for EV charging in driving pattern and a cooperative EV charging and discharging scheme in parking pattern to improve the QoE of using EV and enhance the reliability of the power grid. For traveling planaware scheduling, the assignment of EVs to Charging Stations (CSs) is modeled as a many-to-one matching game and the Stable Matching Algorithm (SMA) is proposed. For cooperative EV charging and discharging in parking pattern, the electricity exchange between charging EVs and discharging EVs in the same parking lot is formulated as a many-to-many matching model with ties, and we develop the Pareto Optimal Matching Algorithm (POMA). Simulation results indicates that the SMA can significantly improve the average system utility for EV charging in driving pattern, and the POMA can increase the amount of electricity offloaded from the grid which is helpful to enhance the reliability of the power grid.
Resumo:
A model system is presented using human umbilical vein endothelial cells (HUVECs) to investigate the role of homocysteine (Hcy) in atherosclerosis. HUVECs are shown to export Hcy at a rate determined by the flux through the methionine/Hcy pathway. Additional methionine increases intracellular methionine, decreases intracellular folate, and increases Hcy export, whereas additional folate inhibits export. An inverse relationship exists between intracellular folate and Hcy export. Hcy export may be regulated by intracellular S-adenosyl methionine rather than by Hcy. Human LDLs exposed to HUVECs exporting Hcy undergo time-related lipid oxidation, a process inhibited by the thiol trap dithionitrobenzoate. This is likely to be related to the generation of hydroxyl radicals, which we show are associated with Hcy export. Although Hcy is the major oxidant, cysteine also contributes, as shown by the effect of glutamate. Finally, the LDL oxidized in this system showed a time-dependent increase in uptake by human macrophages, implying an upregulation of the scavenger receptor. These results suggest that continuous export of Hcy from endothelial cells contributes to the generation of extracellular hydroxyl radicals, with associated oxidative modification of LDL and incorporation into macrophages, a key step in atherosclerosis. Factors that regulate intracellular Hcy metabolism modulate these effects. Copyright © 2005 by the American Society for Biochemistry and Molecular Biology, Inc.
Resumo:
Purpose – The purpose of the paper is to use a case study setting involving the implementation of an enterprise resource planning (ERP) system to expose and analyze the conflicts in the characterizations of the post bureaucratic organisation (PBO) in the literature. ERP implementations are often accompanied by increasing levels of stress in organizations that place pressures on organizational relationships and structures. Additionally, ERPs are regarded as introducing their own techno-logic of centralization, standardization and formalization that provides an apparent contrast to the exhortations about employee empowerment. Design/methodology/approach – A case study of ERP implementation in a medium-sized entity is presented. The paper explores aspects of ERP and PBO from the context of postmodern organization theory. Findings – Some concerns about PBO identified in the literature are reflected in the case situation. For example, there is a commitment to give up private time and work flexibly by some employees. The paper also provides evidence of the way the management team substitute their reliance on a key individual knowledge worker for that of an ERP system and external vendor support. Paradoxically, trust in that same knowledge worker and between core users of the system is essential to enable the implementation of the system. Originality/value – This paper adds empirical insight to a predominantly theoretical literature. The case evidence indicates some conflicting implications in the concurrent adoption of PBO and ERP.
Resumo:
The density and spatial distribution of the vacuoles, glial cell nuclei and glial cytoplasmic inclusions (GCI) were studied in the white matter of various cortical and subcortical areas in 10 cases of multiple system atrophy (MSA). Vacuolation was more prevalent in subcortical than cortical areas and especially in the central tegmental tract. Glial cell nuclei widespread in all areas of the white matter studied; overall densities of glial cell nuclei being significantly greater in the central tegmental tract and frontal cortex compared with areas of the pons. The GCI were present most consistently in the external and internal capsules, the central tegmental tract and the white matter of the cerebellar cortex. The density of the vacuoles was greater in the MSA brains than in the control brains but glial cell density was similar in both groups. In the majority of areas, the pathological changes were distributed across the white matter randomly, uniformly, or in large diffuse clusters. In most areas, there were no spatial correlations between the vacuoles, glial cell nuclei and GCI. These results suggest: (i) there is significant degeneration of the white matter in MSA characterized by vacuolation and GCI; (ii) the central tegmental tract is affected significantly more than the cortical tracts; (iii) pathological changes are diffusely rather than topographically distributed across the white matter; and (iv) the development of the vacuoles and GCI appear to be unrelated phenomena. © 2007 Japanese Society of Neuropathology.
Resumo:
In cases of multiple system atrophy (MSA), glial cytoplasmic inclusions (GCI) were distributed randomly or present in large diffuse clusters (>1,600 μm in diameter) in most areas studied. These spatial patterns contrast with those reported for filamentous neuronal inclusions in the tauopathies and α-synucleinopathies. © 2003 Movement Disorder Society.
Resumo:
Residual current-operated circuit-breakers (RCCBs) have proved useful devices for the protection of both human beings against ventricular fibrillation and installations against fire. Although they work well with sinusoidal waveforms, there is little published information on their characteristics. Due to shunt connected non-linear devices, not the least of which is the use of power electronic equipment, the supply is distorted. Consequently, RCCBs as well as other protection relays are subject to non-sinusoidal current waveforms. Recent studies showed that RCCBs are greatly affected by harmonics, however the reasons for this are not clear. A literature search has also shown that there are inconsistencies in the analysis of the effect of harmonics on protection relays. In this work, the way RCCBs operate is examined, then a model is built with the aim of assessing the effect of non-sinusoidal current on RCCBs. Tests are then carried out on a number of RCCBs and these, when compared with the results from the model showed good correlation. In addition, the model also enables us to explain the RCCBs characteristics for pure sinusoidal current. In the model developed, various parameters are evaluated but special attention is paid to the instantaneous value of the current and the tripping mechanism movement. A similar assessment method is then used to assess the effect of harmonics on two types of protection relay, the electromechanical instantaneous relay and time overcurrent relay. A model is built for each of them which is then simulated on the computer. Tests results compare well with the simulation results, and thus the model developed can be used to explain the relays behaviour in a harmonics environment. The author's models, analysis and tests show that RCCBs and protection relays are affected by harmonics in a way determined by the waveform and the relay constants. The method developed provides a useful tool and the basic methodology to analyse the behaviour of RCCBs and protection relays in a harmonics environment. These results have many implications, especially the way RCCBs and relays should be tested if harmonics are taken into account.
Resumo:
In this thesis various mathematical methods of studying the transient and dynamic stabiIity of practical power systems are presented. Certain long established methods are reviewed and refinements of some proposed. New methods are presented which remove some of the difficulties encountered in applying the powerful stability theories based on the concepts of Liapunov. Chapter 1 is concerned with numerical solution of the transient stability problem. Following a review and comparison of synchronous machine models the superiority of a particular model from the point of view of combined computing time and accuracy is demonstrated. A digital computer program incorporating all the synchronous machine models discussed, and an induction machine model, is described and results of a practical multi-machine transient stability study are presented. Chapter 2 reviews certain concepts and theorems due to Liapunov. In Chapter 3 transient stability regions of single, two and multi~machine systems are investigated through the use of energy type Liapunov functions. The treatment removes several mathematical difficulties encountered in earlier applications of the method. In Chapter 4 a simple criterion for the steady state stability of a multi-machine system is developed and compared with established criteria and a state space approach. In Chapters 5, 6 and 7 dynamic stability and small signal dynamic response are studied through a state space representation of the system. In Chapter 5 the state space equations are derived for single machine systems. An example is provided in which the dynamic stability limit curves are plotted for various synchronous machine representations. In Chapter 6 the state space approach is extended to multi~machine systems. To draw conclusions concerning dynamic stability or dynamic response the system eigenvalues must be properly interpreted, and a discussion concerning correct interpretation is included. Chapter 7 presents a discussion of the optimisation of power system small sjgnal performance through the use of Liapunov functions.
Resumo:
There is currently, no ideal system for studying nasal drug delivery in vitro. The existing techniques such as the Ussing chamber and cell culture all have major disadvantages. Most importantly, none of the existing techniques accurately represent the interior of the nasal cavity, with its airflow and humidity; neither do they allow the investigation of solid dosage forms.The work in this thesis represents the development of an in vitro model system in which the interior characteristics of the nasal cavity are closely represented, and solid or minimal volume dosage forms can be investigated. The complete nasal chamber consists of two sections: a lower tissue, viability chamber and an upper nasal chamber. The lower tissue viability chamber has been shown, using existing tissue viability monitoring techniques, to maintain the viability of a number of epithelial tissues, including porcine and rabbit nasal tissue, and rat ileal and Payers' patch tissue. The complete chamber including the upper nasal chamber has been shown to provide tissue viability for porcine and rabbit nasal tissue above that available using the existing Ussing chamber techniques. Adaptation of the complete system, and the development of the necessary experimental protocols that allow aerosol particle-sizing, together with videography, has shown that the new factors investigated, humidity and airflow, have a measurable effect on the delivered dose from a typical nasal pump. Similarly, adaptation of the chamber to fit under a confocal microscope, and the development of the necessary protocols has shown the effect of surface and size on the penetration of microparticulate materials into nasal epithelial tissues. The system developed in this thesis has been shown to be flexible, in allowing the development of the confocal and particle-sizing systems. For future nasal drug delivery studies, the ability to measure such factors as the size of the delivered system in the nasal cavity, the depth of penetration of the formulation into the tissue are essential. Additionally, to have access to other data such as that obtained from drug transport in the same system, and to have the tissue available for histological examination represents a significant advance in the usefulness of such an in vitro technique for nasal delivery.
Resumo:
The absence of a definitive approach to the design of manufacturing systems signifies the importance of a control mechanism to ensure the timely application of relevant design techniques. To provide effective control, design development needs to be continually assessed in relation to the required system performance, which can only be achieved analytically through computer simulation. The technique providing the only method of accurately replicating the highly complex and dynamic interrelationships inherent within manufacturing facilities and realistically predicting system behaviour. Owing to the unique capabilities of computer simulation, its application should support and encourage a thorough investigation of all alternative designs. Allowing attention to focus specifically on critical design areas and enabling continuous assessment of system evolution. To achieve this system analysis needs to efficient, in terms of data requirements and both speed and accuracy of evaluation. To provide an effective control mechanism a hierarchical or multi-level modelling procedure has therefore been developed, specifying the appropriate degree of evaluation support necessary at each phase of design. An underlying assumption of the proposal being that evaluation is quick, easy and allows models to expand in line with design developments. However, current approaches to computer simulation are totally inappropriate to support the hierarchical evaluation. Implementation of computer simulation through traditional approaches is typically characterized by a requirement for very specialist expertise, a lengthy model development phase, and a correspondingly high expenditure. Resulting in very little and rather inappropriate use of the technique. Simulation, when used, is generally only applied to check or verify a final design proposal. Rarely is the full potential of computer simulation utilized to aid, support or complement the manufacturing system design procedure. To implement the proposed modelling procedure therefore the concept of a generic simulator was adopted, as such systems require no specialist expertise, instead facilitating quick and easy model creation, execution and modification, through simple data inputs. Previously generic simulators have tended to be too restricted, lacking the necessary flexibility to be generally applicable to manufacturing systems. Development of the ATOMS manufacturing simulator, however, has proven that such systems can be relevant to a wide range of applications, besides verifying the benefits of multi-level modelling.
Resumo:
The computer simulation of manufacturing systems is commonly carried out using discrete event simulation (DES). Indeed, there appears to be a lack of applications of continuous simulation methods, particularly system dynamics (SD), despite evidence that this technique is suitable for industrial modelling. This paper investigates whether this is due to a decline in the general popularity of SD, or whether modelling of manufacturing systems represents a missed opportunity for SD. On this basis, the paper first gives a review of the concept of SD and fully describes the modelling technique. Following on, a survey of the published applications of SD in the 1990s is made by developing and using a structured classification approach. From this review, observations are made about the application of the SD method and opportunities for future research are suggested.
Resumo:
Integrated vehicle health management (IVHM) is a collection of data relevant to the present and future performance of a vehicle system and its transformation into information can be used to support operational decisions. This design and operation concept embraces an integration of sensors, communication technologies, and artificial intelligence to provide vehicle-wide abilities to diagnose problems and recommend solutions. This article aims to report the state-of-the-art of IVHM research by presenting a systematic review of the literature. The literature from different sources is collated and analysed, and the major emerging themes are presented. On this basis, the article describes the IVHM concept and its evolution, discusses configurations and existing applications along with main drivers, potential benefits and barriers to adoption, summarizes design guidelines and available methods, and identifies future research challenges.
Resumo:
OBJECTIVE: To determine the distribution of the pathological changes in the neocortex in multiple-system atrophy (MSA). METHOD: The vertical distribution of the abnormal neurons (neurons with enlarged or atrophic perikarya), surviving neurons, glial cytoplasmic inclusions (GCI) and neuronal cytoplasmic inclusions (NI) were studied in alpha-synuclein-stained material of frontal and temporal cortex in ten cases of MSA. RESULTS: Abnormal neurons exhibited two common patterns of distribution, viz., density was either maximal in the upper cortex or a bimodal distribution was present with a density peak in the upper and lower cortex. The NI were either located in the lower cortex or were more uniformly distributed down the cortical profile. The distribution of the GCI varied considerably between gyri and cases. The density of the glial cell nuclei was maximal in the lower cortex in the majority of gyri. In a number of gyri, there was a positive correlation between the vertical densities of the abnormal neurons, the total number of surviving neurons, and the glial cell nuclei. The vertical densities of the GCI were not correlated with those of the surviving neurons or glial cells but the GCI and NI were positively correlated in a small number of gyri. CONCLUSION: The data suggest that there is significant degeneration of the frontal and temporal lobes in MSA, the lower laminae being affected more significantly than the upper laminae. Cortical degeneration in MSA is likely to be secondary to pathological changes occurring within subcortical areas.
Resumo:
Background and Objective: Medication non-compliance is a considerable obstacle in achievinga therapeutic goal, whichcan result in poorerhealthcare outcomes, increased expenditure, wastage and potential for medication resistance. The UK Government’s Audit Commission’s publication ‘A Spoonful of Sugar’1 addresses these issues and promotes self-medication systems as a possible solution. The self-medication system within the Liver Transplant Unit (LTU) was implemented to induct patients onto new post- transplantation medication regimes ready for discharge. The system involves initial consultations with both the Liver Transplant Pharmacist and Trans- plant Co-ordinator, supported with additional advice as and when necessary. Design: Following ethical approval, evaluation of the self-medication sys- tem for liver transplant patients was conducted between January and March 2004 via two methods: audit and structured post-transplantation interview. The audit enabled any discrepancies between current Hospital guidelines and Liver Transplant Unit (LTU) practices to be highlighted. Patient interviews generated a retrospective insight into patient acceptance of the self-medication system. Setting: LTU, Queen Elizabeth Hospital, Birmingham, England. Main Outcome Measures: LTU compliance with Hospital self-medication guidelines and patient insight into self-medication system. Results: A total of seven patients were audited. Findings illustrated that self- medication by transplant patients is a complex process which was not fully addressed by current Hospital self-medication guidelines. Twenty-three patients were interviewed, showing an overwhelming positive attitude to- wards participating in their own care and a high level of understanding towards their individual medication regimes. Following a drugs counselling session, 100% of patients understood why they were taking their medica- tion, and their doses, 95% understood how to take their medication and 85% were aware of potential side effects. Conclusions: From this pilot evaluation it can be stated that the LTU self-medication system is appreciated by patients and assists them in fully understanding their medication regimes. There appear to be no major defects in the system. However areas such as communication barriers and on-going internet education were illustrated as areas for possible future investigation. References: 1. Audit Commission. A spoonful of sugar – medicines management in NHS hospitals. London: Audit Commission; 2001.