19 resultados para Hypertension gestationnelle expérimentale

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess whether blood pressure control in primary care could be improved with the use of patient held targets and self monitoring in a practice setting, and to assess the impact of these on health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences, and costs. DESIGN: Randomised controlled trial. SETTING: Eight general practices in south Birmingham. PARTICIPANTS: 441 people receiving treatment in primary care for hypertension but not controlled below the target of < 140/85 mm Hg. INTERVENTIONS: Patients in the intervention group received treatment targets along with facilities to measure their own blood pressure at their general practice; they were also asked to visit their general practitioner or practice nurse if their blood pressure was repeatedly above the target level. Patients in the control group received usual care (blood pressure monitoring by their practice). MAIN OUTCOME MEASURES: Primary outcome: change in systolic blood pressure at six months and one year in both intervention and control groups. Secondary outcomes: change in health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences of method of blood pressure monitoring, and costs. RESULTS: 400 (91%) patients attended follow up at one year. Systolic blood pressure in the intervention group had significantly reduced after six months (mean difference 4.3 mm Hg (95% confidence interval 0.8 mm Hg to 7.9 mm Hg)) but not after one year (mean difference 2.7 mm Hg (- 1.2 mm Hg to 6.6 mm Hg)). No overall difference was found in diastolic blood pressure, anxiety, health behaviours, or number of prescribed drugs. Patients who self monitored lost more weight than controls (as evidenced by a drop in body mass index), rated self monitoring above monitoring by a doctor or nurse, and consulted less often. Overall, self monitoring did not cost significantly more than usual care (251 pounds sterling (437 dollars; 364 euros) (95% confidence interval 233 pounds sterling to 275 pounds sterling) versus 240 pounds sterling (217 pounds sterling to 263 pounds sterling). CONCLUSIONS: Practice based self monitoring resulted in small but significant improvements of blood pressure at six months, which were not sustained after a year. Self monitoring was well received by patients, anxiety did not increase, and there was no appreciable additional cost. Practice based self monitoring is feasible and results in blood pressure control that is similar to that in usual care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis sets out to examine in detail the condition of systemic hypertension (high Blood Pressure) in relation to optometric practice in the United Kingdom. Systemic hypertension, which is asymptomatic in the early stages, is diagnosed from the Blood Pressure (BP) measurement recorded by a sphygmomanometer and/or from the complications that have developed in target organs. Optometric practice based surveys revealed that diagnosed systemic hypertension was the most prevalent cardiovascular medical condition (20.5%). Measurement of BP of patients in this sample revealed that if an optometrist included sphygmomanometry into the sight examination then at least one patient each day would be referred for suspect systemic hypertension. Optometric opinion felt that the measurement of BP in optometric practice would advance the profession, being appreciated by both patients and General Practitioners (GPs), but was felt to be an unnecessary routine procedure. The present sight examination for the systemic hypertensive is similar to that of the normotensive patient, but may involve an altered fundus examination and a visual field test. The GPs were in favour of optometric BP measurement and a future role in the share care management of the systemic hypertensive. The application of a new pictorial grading scale for the grading of vascular changes associated with pre-malignant systemic hypertension was found to be both accurate and reliable. Clinical trial of the grading scale in optometric practice found positive correlations between BP and increasing severity of the retinal vascular features. The subtle pre-malignant vascular changes require reliable accurate detection and analysis to assist in the management of the systemic hypertensive patient. Vessel width was shown to decrease with increasing age. Image analysis of the A/V ratio, arteriolar tortuosity and focal calibre changes revealed a positive correlation to the patient's BP (p<0.001). The retinal vasculature is relatively stable longitudinally with only minor changes in response to early disease states. Age and elevated BP increased a patient's risk of developing systemic medical conditions over a two-year period. The application of the pictorial grading scale to optometric practice and training the optometrist in the use of sphygmomanometry would improve the management of the systemic hypertensive patient in optometric practice. Future advances in image analysis hold substantial benefits for the detection and monitoring of subtle vascular changes associated with systemic hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Pulmonary arterial hypertension [1] is a proliferative disorder associated with enhanced proliferation and suppressed apoptosis of pulmonary artery smooth muscle cells (PASMCs). Reactive oxygen species (ROS) is implicated in the development of PAH and regulates the vascular tone and functions. However, which cellular signaling mechanisms are triggered by ROS in PAH is still unknown. Hence, here we wished to characterize the signaling mechanisms triggered by ROS. Methods and Results: By Western blots, we showed that increased intracellular ROS caused inhibition of the glycolytic pyruvate kinase M2 (PKM2) activity through promoting the phosphorylation of PKM2. Monocrotaline (MCT)-induced rats developed severe PAH and right ventricular hypertrophy, with a significant increase in the P-PKM2 and decrease in pyruvate kinase activity which could be attenuated with the treatments of PKM2 activators, FBP and l-serine. The antioxidant NAC, apocynin and MnTBAP had the similar protective effects in the development of PAH. In vitro assays confirmed that inhibition of PKM2 activity could modulate the flux of glycolytic intermediates in support of cell proliferation through the increased pentose phosphate pathway (PPP). Increased ROS and decreased PKM2 activity also promoted the Cav1.2 expression and intracellular calcium. Conclusion: Our data provide new evidence that PKM2 makes a critical regulatory contribution to the PAHs for the first time. Decreased pyruvate kinase M2 activity confers additional advantages to rat PASMCs by allowing them to sustain anti-oxidant responses and thereby support cell survival in PAH. It may become a novel treatment strategy in PAH by using of PKM2 activators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background—The exact etiology of preeclampsia is unknown, but there is growing evidence of an imbalance in angiogenic growth factors and abnormal placentation. Hydrogen sulfide (H2S), a gaseous messenger produced mainly by cystathionine ?-lyase (CSE), is a proangiogenic vasodilator. We hypothesized that a reduction in CSE activity may alter the angiogenic balance in pregnancy and induce abnormal placentation and maternal hypertension. Methods and Results—Plasma levels of H2S were significantly decreased in women with preeclampsia (P<0.01), which was associated with reduced placental CSE expression as determined by real-time polymerase chain reaction and immunohistochemistry. Inhibition of CSE activity by DL-propargylglycine reduced placental growth factorproduction from first-trimester (8–12 weeks gestation) human placental explants and inhibited trophoblast invasion in vitro. Knockdown of CSE in human umbilical vein endothelial cells by small-interfering RNA increased the release of soluble fms-like tyrosine kinase-1 and soluble endoglin, as assessed by enzyme-linked immunosorbent assay, whereas adenoviral-mediated CSE overexpression in human umbilical vein endothelial cells inhibited their release. Administration of DL-propargylglycine to pregnant mice induced hypertension and liver damage, promoted abnormal labyrinth vascularization in the placenta, and decreased fetal growth. Finally, a slow-releasing H2S-generating compound, GYY4137, inhibited circulating soluble fms-like tyrosine kinase-1 and soluble endoglin levels and restored fetal growth in mice that was compromised by DL-propargylglycine treatment, demonstrating that the effect of CSE inhibitor was attributable to inhibition of H2S production. Conclusions—These results imply that endogenous H2S is required for healthy placental vasculature and that a decrease in CSE/H2S activity may contribute to the pathogenesis of preeclampsia. (Circulation. 2013;127:2514-2522.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NADPH oxidase (Nox)-derived reactive oxygen species (ROS) are known to be involved in angiotensin II-induced hypertension and endothelial dysfunction. Several Nox isoforms are expressed in the vessel wall, among which Nox2 is especially abundant in the endothelium. Endothelial Nox2 levels rise during hypertension but little is known about the cell-specific role of endothelial Nox2 in vivo. To address this question, we generated transgenic mice with endothelial-specific overexpression of Nox2 (Tg) and studied the effects on endothelial function and blood pressure. Tg had an about twofold increase in endothelial Nox2 levels which was accompanied by an increase in p22phox levels but no change in levels of other Nox isoforms or endothelial nitric oxide synthase (eNOS). Basal NADPH oxidase activity, endothelial function and blood pressure were unaltered in Tg compared to wild-type littermates. Angiotensin II caused a greater increase in ROS production in Tg compared to wild-type aorta and attenuated acetylcholine-induced vasorelaxation. Both low and high dose chronic angiotensin II infusion increased telemetric ambulatory blood pressure more in Tg compared to wild-type, but with different patterns of BP change and aortic remodeling depending upon the dose of angiotensin II dose. These results indicate that an increase in endothelial Nox2 levels contributes to angiotensin II-induced endothelial dysfunction, vascular remodeling and hypertension. © 2011 The Author(s).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Humans with inactivating mutations in peroxisomal proliferators activated receptor gamma (PPAR?) typically develop a complex metabolic syndrome characterized by insulin resistance, diabetes, lipodystrophy, hypertension, and dyslipidaemia which is likely to increase their cardiovascular risk. Despite evidence that the activation of PPAR? may prevent cardiac fibrosis and hypertrophy, recent evidence has suggested that pharmacological activation of PPAR? causes increased cardiovascular mortality. In this study, we investigated the effects of defective PPAR? function on the development of cardiac fibrosis and hypertrophy in a murine model carrying a human dominant-negative mutation in PPAR?. Methods and results: Mice with a dominant-negative point mutation in PPAR? (P465L) and their wild-type (WT) littermates were treated with either subcutaneous angiotensin II (AngII) infusion or saline for 2 weeks. Heterozygous P465L and WT mice developed a similar increase in systolic blood pressure, but the mutant mice developed significantly more severe cardiac fibrosis to AngII that correlated with increased expression of profibrotic genes. Both groups similarly increased the heart weight to body weight ratio compared with saline-treated controls. There were no differences in fibrosis between saline-treated WT and P465L mice. Conclusion: These results show synergistic pathogenic effects between the presence of defective PPAR? and AngII-induced hypertension and suggest that patients with PPAR? mutation and hypertension may need more aggressive therapeutic measures to reduce the risk of accelerated cardiac fibrosis. © The Author 2009.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Systemic hypertension is a silent killer that may have very few warning signs. This study examines detection and management of patients with cardiovascular disease (CVD) by optometrists in the UK. Method: A survey was sent out to 1402 optometrists who practice in the UK to investigate the nature and knowledge of detection of systemic hypertension. Results: The survey response rate was 37%. Optometrists were neutral to slightly positive towards the use of blood pressure (BP) monitors, but not on a routine basis. The most frequently asked question during history and symptoms concerned the patient's prescribed medication for systemic hypertension, and the least was that of specifying the last BP measurement. The additional test most widely used in the examination of the systemic hypertensive patient was direct ophthalmoscopy with red-free filter. Over one-tenth of optometric practices had a BP monitor, with automated devices being the most popular. Patients most likely to have their BP measured were suspect systemic hypertensives. Retinal haemorrhages are the most important finding in influencing an optometrist's referral criteria for suspected systemic hypertension. Conclusion: Although optometrists monitor the retina for signs of damage from systemic hypertension, further education in this important condition is warranted. © 2005 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-The exact etiology of preeclampsia is unknown, but there is growing evidence of an imbalance in angiogenic growth factors and abnormal placentation. Hydrogen sulfide (H2S), a gaseous messenger produced mainly by cystathionine γ-lyase (CSE), is a proangiogenic vasodilator. We hypothesized that a reduction in CSE activity may alter the angiogenic balance in pregnancy and induce abnormal placentation and maternal hypertension. Methods and Results-Plasma levels of H2S were significantly decreased in women with preeclampsia (P<0.01), which was associated with reduced placental CSE expression as determined by real-time polymerase chain reaction and immunohistochemistry. Inhibition of CSE activity by DL-propargylglycine reduced placental growth factorproduction from first-trimester (8-12 weeks gestation) human placental explants and inhibited trophoblast invasion in vitro. Knockdown of CSE in human umbilical vein endothelial cells by small-interfering RNA increased the release of soluble fms-like tyrosine kinase-1 and soluble endoglin, as assessed by enzyme-linked immunosorbent assay, whereas adenoviral-mediated CSE overexpression in human umbilical vein endothelial cells inhibited their release. Administration of DL-propargylglycine to pregnant mice induced hypertension and liver damage, promoted abnormal labyrinth vascularization in the placenta, and decreased fetal growth. Finally, a slow-releasing H2S-generating compound, GYY4137, inhibited circulating soluble fms-like tyrosine kinase-1 and soluble endoglin levels and restored fetal growth in mice that was compromised by DL-propargylglycine treatment, demonstrating that the effect of CSE inhibitor was attributable to inhibition of H2S production. Conclusions-These results imply that endogenous H2S is required for healthy placental vasculature and that a decrease in CSE/H2S activity may contribute to the pathogenesis of preeclampsia. © 2013 American Heart Association, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In addition to being the chief cause of death in developed countries, systemic hypertension is also a leading cause of visual impairment. The eye is an end arteriolar system and is therefore susceptible to changes in blood pressure. It is also the only place where blood vessels can be clearly viewed by noninvasive techniques. This paper reviews current research into premalignant and malignant retinal signs of systemic hypertension. Previous methods of classifying retinal hypertensive signs are identified, along with more recent image analysis techniques. The need for observing the retinal vasculature as well as measuring blood pressure for monitoring systemic hypertensive patients is discussed in relation to current research. Copyright © 2002 by Current Science Inc.