24 resultados para Higher Order Ionosphere Effects

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To study the effects of ocular lubricants on higher order aberrations in normal and self-diagnosed dry eyes. Methods: Unpreserved hypromellose drops, Tears Again™ liposome spray and a combination of both were administered to the right eye of 24 normal and 24 dry eye subjects following classification according to a 5 point questionnaire. Total ocular higher order aberrations, coma, spherical aberration and Strehl ratios for higher order aberrations were measured using the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) at baseline, immediately after application and after 60. min. The aberration data were analyzed over a 5. mm natural pupil using Zernike polynomials. Each intervention was assessed on a separate day and comfort levels were recorded before and after application. Corneal staining was assessed and product preference recorded after the final measurement for each intervention. Results: Hypromellose drops caused an increase in total higher order aberrations (p= <0.01 in normal and dry eyes) and a reduction in Strehl ratio (normal eyes: p= <0.01, dry eyes p= 0.01) immediately after instillation. There were no significant differences between normal and self-diagnosed dry eyes for response to intervention and no improvement in visual quality or reduction in higher order aberrations after 60. min. Differences in comfort levels failed to reach statistical significance. Conclusion: Combining treatments does not offer any benefit over individual treatments in self-diagnosed dry eyes and no individual intervention reached statistical significance. Symptomatic subjects with dry eye and no corneal staining reported an improvement in comfort after using lubricants. © 2013 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analyzing geographical patterns by collocating events, objects or their attributes has a long history in surveillance and monitoring, and is particularly applied in environmental contexts, such as ecology or epidemiology. The identification of patterns or structures at some scales can be addressed using spatial statistics, particularly marked point processes methodologies. Classification and regression trees are also related to this goal of finding "patterns" by deducing the hierarchy of influence of variables on a dependent outcome. Such variable selection methods have been applied to spatial data, but, often without explicitly acknowledging the spatial dependence. Many methods routinely used in exploratory point pattern analysis are2nd-order statistics, used in a univariate context, though there is also a wide literature on modelling methods for multivariate point pattern processes. This paper proposes an exploratory approach for multivariate spatial data using higher-order statistics built from co-occurrences of events or marks given by the point processes. A spatial entropy measure, derived from these multinomial distributions of co-occurrences at a given order, constitutes the basis of the proposed exploratory methods. © 2010 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analyzing geographical patterns by collocating events, objects or their attributes has a long history in surveillance and monitoring, and is particularly applied in environmental contexts, such as ecology or epidemiology. The identification of patterns or structures at some scales can be addressed using spatial statistics, particularly marked point processes methodologies. Classification and regression trees are also related to this goal of finding "patterns" by deducing the hierarchy of influence of variables on a dependent outcome. Such variable selection methods have been applied to spatial data, but, often without explicitly acknowledging the spatial dependence. Many methods routinely used in exploratory point pattern analysis are2nd-order statistics, used in a univariate context, though there is also a wide literature on modelling methods for multivariate point pattern processes. This paper proposes an exploratory approach for multivariate spatial data using higher-order statistics built from co-occurrences of events or marks given by the point processes. A spatial entropy measure, derived from these multinomial distributions of co-occurrences at a given order, constitutes the basis of the proposed exploratory methods. © 2010 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the intercorrelations and the independent and combined factor structures of the Sixteen Personality Factor Questionnaire Fifth Edition (16PF5) and the Fundamental Interpersonal Orientation-Behaviour Scale (FIRO-B). Four thousand four hundred and fourteen U.S. participants completed these measures as part of executive assessments between 1994 and 2003. Exploratory factor analyses supported the five-factor higher-order structure of the 16PF5; however, the three-component structure for the FIRO-B was not supported. A six-factor structure was found to underlie the variance in the measures in combination. Five of these were close to the 16PF5 higher-order structure, but a sixth factor labelled Social Independence also emerged. This new factor consisted of the 16PF5 primaries of Liveliness and Social Boldness, and the FIRO-B Wanted Control scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cadogan and Lee (this issue) discuss the problems inherent in modeling formative latent variables as endogenous. In response to the commentaries by Rigdon (this issue) and Finn and Wang (this issue), the present article extends the discussion on formative measures. First, the article shows that regardless of whether statistical identification is achieved, researchers are unable to illuminate the nature of a formative latent variable. Second, the study clarifies issues regarding formative indicator weighting, highlighting that the weightings of formative components should be specified as part of the construct definition. Finally, the study shows that higher-order reflective constructs are invalid, highlights the damage their use can inflict on theory development and knowledge accumulation, and provides recommendations on a number of alternative models which should be used in their place (including the formative model). © 2012 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the internal higher-order structures of five personality inventories (the Hogan Personality Inventory, the Occupational Personality Questionnaire, the Sixteen Personality Factor Questionnaire, the Personality and Preferences Inventory, Profile Match). A sample of 356 individuals from the UK working population completed various combinations of the five inventories. Overall, the results indicated sensible and interpretable factor structures for the inventories. Cross-inventory factor analyses of the extracted factors revealed a variant of the Big Five model underpinning them, enabling examination of inventory convergence and divergence. Our study also examined and compared representations of the General Factor of Personality in each of the inventories. © 2011 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A thulium-doped all-fibre laser hybrid mode-locked by the co-action of nonlinear polarization evolution and single-walled carbon nanotubes generating 500-fs high-order solitons with the pulse energy 10.87 nJ at 1.9 μm wavelength band is demonstrated. © 2014 OSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A thulium-doped all-fiber laser passively mode-locked by the co-action of nonlinear polarization evolution and single-walled carbon nanotubes operating at 1860-1980 nm wavelength band is demonstrated. Pumped with the single-mode laser diode at 1.55 μm laser generates near 500-fs soliton pulses at repetition rate ranging from 6.3 to 72.5 MHz in single-pulse operation regime. Having 3-m long cavity average output power reached 300 mW, giving the peak power of 4.88 kW and the pulse energy of 2.93 nJ with slope efficiency higher than 30%. At a 21.6-m long ring cavity average output power of 117 mW is obtained, corresponding to the pulse energy up to 10.87 nJ and a pulse peak power of 21.7 kW, leading to the higher-order soliton generation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the different possible amplification solutions offered by Raman scattering in optical fibers, ultra-long Raman lasers are particularly promising as they can provide quasi-losless second order amplification with reduced complexity, displaying excellent potential in the design of low-noise long-distance communication systems. Still, some of their advantages can be partially offset by the transfer of relative intensity noise from the pump sources and cavity-generated Stokes to the transmitted signal. In this paper we study the effect of ultra-long cavity design (length, pumping, grating reflectivity) on the transfer of RIN to the signal, demonstrating how the impact of noise can be greatly reduced by carefully choosing appropriate cavity parameters depending on the intended application of the system. © 2010 Copyright SPIE - The International Society for Optical Engineering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prior research on brand extension has provided little evidence on enhancing the evaluation of extremely incongruent extension. Adopting the theoretical framework of schema congruity theory, the author posits that evaluations can be improved if brand personality impressions of both parent brand and extension are complementary. The author coins this as the brand personality complementarity (BPC) principle. Prior to examining BPC effect, cultural-specific brand personality scale was developed to identify universal and indigenous brand personality dimensions. The reason is BPC requires a reliable and valid brand personality scale in order to detect its effect. Following successful identification of the cultural-specific brand personality scale, a total of three experimental studies were done to investigate BPC effect. Specifically, one experimental study identified complementary levels amongst brand personality dimensions, whereas two experimental studies investigated the moderating effect of BPC. Findings from the scale development study reveal that Malaysian brand personality (MBP) scale is a second higher-order factor reflected by first higher-order factors of sophistication, youth, competence, and sincerity. Most importantly, findings from the experimental studies revealed; 1) different BPC levels amongst all possible pairs of MBP dimensions, 2) significant interaction effect of brand extension congruity x BPC, and 3) significant mediation effect of complementarity resolution. Specific findings indicated that when iv text-based stimuli were used to form brand personality impression, even low BPC level improves the evaluations of extremely incongruent extension. However, when visualbased stimuli were used, low BPC level worsen the extension evaluation compared those of the control condition (i.e. without brand personality impression). Implications for both academician and practitioner are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of instrument realignment and angular misalignment during the clinical determination of wavefront aberrations by simulation in model eyes. Setting: Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom. Methods: Six model eyes were examined with wavefront-aberration-supported cornea ablation (WASCA) (Carl Zeiss Meditec) in 4 sessions of 10 measurements each: sessions 1 and 2, consecutive repeated measures without realignment; session 3, realignment of the instrument between readings; session 4, measurements without realignment but with the model eye shifted 6 degrees angularly. Intersession repeatability and the effects of realignment and misalignment were obtained by comparing the measurements in the various sessions for coma, spherical aberration, and higher-order aberrations (HOAs). Results: The mean differences between the 2 sessions without realignment of the instrument were 0.020 μm ± 0.076 (SD) for Z3 - 1(P = .551), 0.009 ± 0.139 μm for Z3 1(P = .877), 0.004 ± 0.037 μm for Z4 0 (P = .820), and 0.005 ± 0.01 μm for HO root mean square (RMS) (P = .301). Differences between the nonrealigned and realigned instruments were -0.017 ± 0.026 μm for Z3 - 1(P = .159), 0.009 ± 0.028 μm for Z3 1 (P = .475), 0.007 ± 0.014 μm for Z4 0(P = .296), and 0.002 ± 0.007 μm for HO RMS (P = 0.529; differences between centered and misaligned instruments were -0.355 ± 0.149 μm for Z3 - 1 (P = .002), 0.007 ± 0.034 μm for Z3 1(P = .620), -0.005 ± 0.081 μm for Z4 0(P = .885), and 0.012 ± 0.020 μm for HO RMS (P = .195). Realignment increased the standard deviation by a factor of 3 compared with the first session without realignment. Conclusions: Repeatability of the WASCA was excellent in all situations tested. Realignment substantially increased the variance of the measurements. Angular misalignment can result in significant errors, particularly in the determination of coma. These findings are important when assessing highly aberrated eyes during follow-up or before surgery. © 2007 ASCRS and ESCRS.