4 resultados para High Mounted Stop Lamps.

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: "One-stop" outpatient hysteroscopy clinics have become well established for the investigation and treatment of women with abnormal uterine bleeding. However, the advantages of these clinics may be offset by patient factors such as anxiety, pain, and dissatisfaction. This study aimed to establish patients' views and experiences of outpatient service delivery in the context of a one-stop diagnostic and therapeutic hysteroscopy clinic, to determine the amount of anxiety experienced by these women and compare this with other settings, and to determine any predictors for patient preferences. METHODS: The 20-item State-Trait Anxiety Inventory was given to 240 women attending a one-stop hysteroscopy clinic: to 73 consecutive women before their appointment in a general gynecology clinic and to 36 consecutive women attending a chronic pelvic pain clinic. The results were compared with published data for the normal female population, for women awaiting major surgery, and for women awaiting a colposcopy clinic appointment. In addition, a questionnaire designed to ascertain patients' views and experiences was used. Logistic regression analysis was used to delineate the predictive values of diagnostic or therapeutic hysteroscopy, and to determine their effect on the preference of patients to have the procedure performed under general anesthesia in the future. RESULTS: Women attending the hysteroscopy clinic in this study reported significantly higher levels of anxiety than those attending the general gynecology clinic (median, 45 vs 39; p = 0.004), but the levels of anxiety were comparable with those of women attending the chronic pelvic pain clinic (median, 45 vs 46; p = 0.8). As compared with the data from the normal female population (mean, 35.7) and those reported for women awaiting major surgery (mean, 41.2), the levels of anxiety experienced before outpatient hysteroscopy clinic treatment were found to be higher (mean, 45.7). Only women awaiting colposcopy (6-item mean score, 51.1 +/- 13.3) experienced significantly higher anxiety scores than the women awaiting outpatient hysteroscopy (6-item mean score, 47.3 +/- 13.9; p = 0.002). Despite their anxiety, most women are satisfied with the outpatient hysteroscopy "see and treat" service. High levels of anxiety, particularly concerning pain but not operative intervention, were significant predictors of patients desiring a future procedure to be performed under general anesthesia. CONCLUSIONS: Outpatient hysteroscopy is associated with significant anxiety, which increases the likelihood of intolerance for the outpatient procedure. However, among those undergoing operative therapeutic procedures, dissatisfaction was not associated with the outpatient setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Internal quantum efficiency (IQE) of a high-brightness blue LED has been evaluated from the external quantum efficiency measured as a function of current at room temperature. Processing the data with a novel evaluation procedure based on the ABC-model, we have determined separately IQE of the LED structure and light extraction efficiency (LEE) of UX:3 chip. Full text Nowadays, understanding of LED efficiency behavior at high currents is quite critical to find ways for further improve­ment of III-nitride LED performance [1]. External quantum ef­ficiency ηe (EQE) provides integral information on the recom­bination and photon emission processes in LEDs. Meanwhile EQE is the product of IQE ηi and LEE ηext at negligible car­rier leakage from the active region. Separate determination of IQE and LEE would be much more helpful, providing correla­tion between these parameters and specific epi-structure and chip design. In this paper, we extend the approach of [2,3] to the whole range of the current/optical power variation, provid­ing an express tool for separate evaluation of IQE and LEE. We studied an InGaN-based LED fabricated by Osram OS. LED structure grown by MOCVD on sapphire substrate was processed as UX:3 chip and mounted into the Golden Dragon package without molding. EQE was measured with Labsphere CDS-600 spectrometer. Plotting EQE versus output power P and finding the power Pm corresponding to EQE maximum ηm enables comparing the measurements with the analytical rela­tionships ηi = Q/(Q+p1/2+p-1/2) ,p = P/Pm , and Q = B/(AC) 1/2 where A, Band C are recombination constants [4]. As a result, maximum IQE value equal to QI(Q+2) can be found from the ratio ηm/ηe plotted as a function of p1/2 +p1-1/2 (see Fig.la) and then LEE calculated as ηext = ηm (Q+2)/Q . Experimental EQE as a function of normalized optical power p is shown in Fig. 1 b along with the analytical approximation based on the ABC­model. The approximation fits perfectly the measurements in the range of the optical power (or operating current) variation by eight orders of magnitude. In conclusion, new express method for separate evaluation of IQE and LEE of III-nitride LEDs is suggested and applied to characterization of a high-brightness blue LED. With this method, we obtained LEE from the free chip surface to the air as 69.8% and IQE as 85.7% at the maximum and 65.2% at the operation current 350 rnA. [I] G. Verzellesi, D. Saguatti, M. Meneghini, F. Bertazzi, M. Goano, G. Meneghesso, and E. Zanoni, "Efficiency droop in InGaN/GaN blue light-emitting diodes: Physical mechanisms and remedies," 1. AppL Phys., vol. 114, no. 7, pp. 071101, Aug., 2013. [2] C. van Opdorp and G. W. 't Hooft, "Method for determining effective non radiative lifetime and leakage losses in double-heterostructure las­ers," 1. AppL Phys., vol. 52, no. 6, pp. 3827-3839, Feb., 1981. [3] M. Meneghini, N. Trivellin, G. Meneghesso, E. Zanoni, U. Zehnder, and B. Hahn, "A combined electro-optical method for the determination of the recombination parameters in InGaN-based light-emitting diodes," 1. AppL Phys., vol. 106, no. II, pp. 114508, Dec., 2009. [4] Qi Dai, Qifeng Shan, ling Wang, S. Chhajed, laehee Cho, E. F. Schubert, M. H. Crawford, D. D. Koleske, Min-Ho Kim, and Yongjo Park, "Carrier recombination mechanisms and efficiency droop in GalnN/GaN light-emitting diodes," App/. Phys. Leu., vol. 97, no. 13, pp. 133507, Sept., 2010. © 2014 IEEE.