6 resultados para Hartree Fock scheme correlation errors

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditional high speed machinery actuators are powered and coordinated by mechanical linkages driven from a central drive, but these linkages may be replaced by independently synchronised electric drives. Problems associated with utilising such electric drives for this form of machinery were investigated. The research concentrated on a high speed rod-making machine, which required control of high inertias (0.01-0.5kgm2), at continuous high speed (2500 r/min), with low relative phase errors between two drives (0.0025 radians). Traditional minimum energy drive selection techniques for incremental motions were not applicable to continuous applications which require negligible energy dissipation. New selection techniques were developed. A brushless configuration constant enabled the comparison between seven different servo systems; the rate earth brushless drives had the best power rates which is a performance measure. Simulation was used to review control strategies, such that a microprocessor controller with a proportional velocity loop within a proportional position loop with velocity feedforward was designed. Local control schemes were investigated as means of reducing relative errors between drives: the slave of a master/slave scheme compensates for the master's errors: the matched scheme has drives with similar absolute errors so the relative error is minimised, and the feedforward scheme minimises error by adding compensation from previous knowledge. Simulation gave an approximate velocity loop bandwidth and position loop gain required to meet the specification. Theoretical limits for these parameters were defined in terms of digital sampling delays, quantisation, and system phase shifts. Performance degradation due to mechanical backlash was evaluated. Thus any drive could be checked to ensure that the performance specification could be realised. A two drive demonstrator was commissioned with 0.01kgm2 loads. By use of simulation the performance of one drive was improved by increasing the velocity loop bandwidth fourfold. With the master/slave scheme relative errors were within 0.0024 radians at a constant 2500 r/min for two 0.01 kgm^2 loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Correlation and regression are two of the statistical procedures most widely used by optometrists. However, these tests are often misused or interpreted incorrectly, leading to erroneous conclusions from clinical experiments. This review examines the major statistical tests concerned with correlation and regression that are most likely to arise in clinical investigations in optometry. First, the use, interpretation and limitations of Pearson's product moment correlation coefficient are described. Second, the least squares method of fitting a linear regression to data and for testing how well a regression line fits the data are described. Third, the problems of using linear regression methods in observational studies, if there are errors associated in measuring the independent variable and for predicting a new value of Y for a given X, are discussed. Finally, methods for testing whether a non-linear relationship provides a better fit to the data and for comparing two or more regression lines are considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The growth and advances made in computer technology have led to the present interest in picture processing techniques. When considering image data compression the tendency is towards trans-form source coding of the image data. This method of source coding has reached a stage where very high reductions in the number of bits representing the data can be made while still preserving image fidelity. The point has thus been reached where channel errors need to be considered, as these will be inherent in any image comnunication system. The thesis first describes general source coding of images with the emphasis almost totally on transform coding. The transform technique adopted is the Discrete Cosine Transform (DCT) which becomes common to both transform coders. Hereafter the techniques of source coding differ substantially i.e. one tech­nique involves zonal coding, the other involves threshold coding. Having outlined the theory and methods of implementation of the two source coders, their performances are then assessed first in the absence, and then in the presence, of channel errors. These tests provide a foundation on which to base methods of protection against channel errors. Six different protection schemes are then proposed. Results obtained, from each particular, combined, source and channel error protection scheme, which are described in full are then presented. Comparisons are made between each scheme and indicate the best one to use given a particular channel error rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Tilted disc syndrome has been described to be associated with obliquely directed long axis of the disc, oblique direction of vessels, retinal pigment epithelial conus, hypoplasia of retina, visual field defects and myopic astigmatism. This prospective study looks at corneal astigmatism in eyes with a tilted optic disc. Refractive errors in these eyes were also analyzed. Methods: Patients with tilted optic discs were identified prospectively by clinical evaluation (BI, VK). All the patients with obliquely directed long axis of the disc, oblique direction of vessels and retinal pigment epithelial conus were included in the study. Best corrected visual acuity, slit-lamp examination, optic disc measurements, keratometry and refraction were recorded. Results: Twenty four patients (41 eyes) were recruited for the study. Eighteen (75%) patients had bilateral tilted optic discs. Eighteen patients (75%) were females and six (25%) were males. The mean age was 62 years(range 9 – 86 years). 76% of the patients were myopic and 24% hypermetropic. The mean spherical equivalent was –7.49 dioptres (SD 1.7D, range +6D to -17D). The mean corneal astigmatism was 1.09D (SD 0.9D, range 0.25D to 3.80D). The 6 patients who had unilateral, untilted discs were used as a control group to compare their mean corneal astigmatism (1.32 D) with the rest. Student "t" test was performed. ("p" = 0.49). Conclusions: In our study, tilted disc syndrome was found to be largely bilateral and more commonly seen in females. Myopia was the commonest refractive error associated with this clinical condition. However, 24% of patients in this series were hypermetropic. No correlation between the tilting of the optic disc and significant corneal astigmatism was noted as previously reported.