3 resultados para Hard surface
em Aston University Research Archive
Resumo:
Healthcare associated infections may arise from many sources, including patient?s own skin flora and the clinical environment, and inflict a significant burden within the health service. Adequate and effective skin antisepsis and surface disinfection are therefore essential factors in infection control. Current EPIC guidelines recommend 2 % chlorhexidine (CHG) in 70 % isopropyl alcohol (IPA) for skin antisepsis however poor penetration has been reported. Eucalyptus oil (EO) is a known permeation enhancer, producing synergistic antimicrobial activity when combined with CHG. In this current study, the antimicrobial efficacy of EO and its main constituent 1,8-cineole were assessed against a panel of clinically relevant microorganisms, alone and in combination with CHG. The superior antimicrobial efficacy of EO compared with 1,8-cineole, and synergistic effects with CHG against planktonic and biofilm cultures, confirmed its suitability for use in subsequent studies within this thesis. Impregnation of EO, CHG and IPA onto prototype hard surface disinfectant wipes demonstrated significantly improved efficacy compared with CHG/IPA wipes, with clear reductions in the time required to eliminate biofilms. Optimisation of the EO/CHG/IPA formulation resulted in the development of Euclean® wipes, with simulated-use and time kill studies confirming their ability to remove microbial surface contamination, prevent cross contamination and eliminate biofilms within 10 minutes. The employment of isothermal calorimetry provided additional information on the type and rate of antimicrobial activity possessed by Euclean® wipes. A clinical audit of the Euclean® wipes at Birmingham Children?s Hospital, Birmingham, U.K. revealed divided staff opinion, with the highest cited advantage and disadvantage concerning the odour. Finally, skin penetration and cell toxicity studies of EO/CHG biopatches and Euclean® solution developed during this study, revealed no permeation into human skin following biopatch application, and no significant toxicity. These current studies enhance the knowledge regarding EO and its potential applications.
Resumo:
This thesis has sought to investigate disinfection agents and procedures which may provide sanitisation against bacterial spores. A hard-surface disinfection test method was designed to ascertain which combinations of biocide and application method were most effective against bacterial spores. A combination of spraying and wiping was the most effective method of disinfection against Bacillus spores, with wiping found to play a key role in spore removal. The most efficacious of the biocides investigated was the 6% hydrogen peroxide. Vaporised Hydrogen Peroxide (VHP) gassing was more effective than traditional disinfection. In addition to efficacy, the toxic potential of the biocides to human airway epithelial cells in vitro was evaluated. Toxicity against human bronchial and nasal epithelial cells was assessed by determining cell viability, inflammatory status, protein oxidation and epithelial cell layer integrity. In addition the cell death mechanism following biocide exposure was investigated. There was a decrease in viable cells following exposure to all biocides when applied at practical concentrations. Almost all of the biocides tested elicited a pro-inflammatory response from the cells as measured by IL-8 production. All biocides increased protein oxidation as measured by thiol and carbonyl levels. Measurement of transepithelial electrical resistance and paracellular permeability indicated biocide-dependent decrease in epithelial cell barrier function. The cellular response was biased towards necrotic rather than apoptotic death. The use of biocides, although efficacious to some effects against Bacillus spores, will require careful monitoring for adverse health effects on personnel.
Resumo:
Issues of wear and tribology are increasingly important in computer hard drives as slider flying heights are becoming lower and disk protective coatings thinner to minimise spacing loss and allow higher areal density. Friction, stiction and wear between the slider and disk in a hard drive were studied using Accelerated Friction Test (AFT) apparatus. Contact Start Stop (CSS) and constant speed drag tests were performed using commercial rigid disks and two different air bearing slider types. Friction and stiction were captured during testing by a set of strain gauges. System parameters were varied to investigate their effect on tribology at the head/disk interface. Chosen parameters were disk spinning velocity, slider fly height, temperature, humidity and intercycle pause. The effect of different disk texturing methods was also studied. Models were proposed to explain the influence of these parameters on tribology. Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM) were used to study head and disk topography at various test stages and to provide physical parameters to verify the models. X-ray Photoelectron Spectroscopy (XPS) was employed to identify surface composition and determine if any chemical changes had occurred as a result of testing. The parameters most likely to influence the interface were identified for both CSS and drag testing. Neural Network modelling was used to substantiate results. Topographical AFM scans of disk and slider were exported numerically to file and explored extensively. Techniques were developed which improved line and area analysis. A method for detecting surface contacts was also deduced, results supported and explained observed AFT behaviour. Finally surfaces were computer generated to simulate real disk scans, this allowed contact analysis of many types of surface to be performed. Conclusions were drawn about what disk characteristics most affected contacts and hence friction, stiction and wear.