7 resultados para GPS PPP precise point positioning GrafMov RTKLIB satellite

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

For optimum utilization of satellite-borne instrumentation, it is necessary to know precisely the orbital position of the spacecraft. The aim of this thesis is therefore two-fold - firstly to derive precise orbits with particular emphasis placed on the altimetric satellite SEASAT and secondly, to utilize the precise orbits, to improve upon atmospheric density determinations for satellite drag modelling purposes. Part one of the thesis, on precise orbit determinations, is particularly concerned with the tracking data - satellite laser ranging, altimetry and crossover height differences - and how this data can be used to analyse errors in the orbit, the geoid and sea-surface topography. The outcome of this analysis is the determination of a low degree and order model for sea surface topography. Part two, on the other hand, mainly concentrates on using the laser data to analyse and improve upon current atmospheric density models. In particular, the modelling of density changes associated with geomagnetic disturbances comes under scrutiny in this section. By introducing persistence modelling of a geomagnetic event and solving for certain geomagnetic parameters, a new density model is derived which performs significantly better than the state-of-the-art models over periods of severe geomagnetic storms at SEASAT heights. This is independently verified by application of the derived model to STARLETTE orbit determinations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The work described in this thesis concerns the application of radar altimetry, collected from the ERS-1 and TOPEX/POSEIDON missions, to precise satellite orbits computed at Aston University. The data is analysed in a long arc fashion to determine range biases, time tag biases, sea surface topographies and to assess the radial accuracy of the generated orbits through crossover analysis. A sea surface variability study is carried out for the North Sea using repeat altimeter profiles from ERS-1 and TOPEX/POSEIDON in order to verify two local U.K. models for ocean tide and storm surge effects. An on-side technique over the English Channel is performed to compute the ERS-1, TOPEX and POSEIDON altimeter range biases by using a combination of altimetry, precise orbits determined by short arc methods, tide gauge data, GPS measurements, geoid, ocean tide and storm surge models. The remaining part of the thesis presents some techniques for the short arc correction of long arc orbits. Validation of this model is achieved by way of comparison with actual SEASAT short arcs. Simulations are performed for the ERS-1 microwave tracking system, PRARE, using the range data to determine time dependent orbit corrections. Finally, a brief chapter is devoted to the recovery of errors in station coordinates by the use of multiple short arcs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The technique of Satellite Laser Ranging is today a mature, important tool with applications in many area of geodynamics, geodesy and satellite dynamics. A global network of some 40 stations regularly obtains range observations with sub-cm precision to more than twelve orbiting spacecraft. At such levels of precision it is important to minimise potential sources of range bias in the observations, and part of the thesis is a study of subtle effects caused by the extended nature of the arrays of retro-reflectors on the satellites. We develop models that give a precise correction of the range measurements to the centres of mass of the geodetic satellites Lageos and Etalon, appropriate to a variety of different ranging systems, and use the Etalon values, which were not determined during pre-launch tests, in an extended orbital analysis. We have fitted continuous 2.5 year orbits to range observations of the Etalons from the global network of stations, and analysed the results by mapping the range residuals from these orbits into equivalent corrections to orbital elements over short time intervals. From these residuals we have detected and studied large un-modelled along-track accelerations associated with periods during which the satellites are undergoing eclipse by the Earth's shadow. We also find that the eccentricity residuals are significantly different for the two satellites, with Etalon-2 undergoing a year-long eccentricity anomaly similar in character to that experienced at intervals by Lageos-1. The nodal residuals show that the satellites define a very stable reference frame for Earth rotation determination, with very little drift-off during the 2.5 year period. We show that an analysis of more than about eight years of tracking data would be required to derive a significant value for 2. The reference frame defined by the station coordinates derived from the analyses shows very good agreement with that of ITRF93.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Substantial altimetry datasets collected by different satellites have only become available during the past five years, but the future will bring a variety of new altimetry missions, both parallel and consecutive in time. The characteristics of each produced dataset vary with the different orbital heights and inclinations of the spacecraft, as well as with the technical properties of the radar instrument. An integral analysis of datasets with different properties offers advantages both in terms of data quantity and data quality. This thesis is concerned with the development of the means for such integral analysis, in particular for dynamic solutions in which precise orbits for the satellites are computed simultaneously. The first half of the thesis discusses the theory and numerical implementation of dynamic multi-satellite altimetry analysis. The most important aspect of this analysis is the application of dual satellite altimetry crossover points as a bi-directional tracking data type in simultaneous orbit solutions. The central problem is that the spatial and temporal distributions of the crossovers are in conflict with the time-organised nature of traditional solution methods. Their application to the adjustment of the orbits of both satellites involved in a dual crossover therefore requires several fundamental changes of the classical least-squares prediction/correction methods. The second part of the thesis applies the developed numerical techniques to the problems of precise orbit computation and gravity field adjustment, using the altimetry datasets of ERS-1 and TOPEX/Poseidon. Although the two datasets can be considered less compatible that those of planned future satellite missions, the obtained results adequately illustrate the merits of a simultaneous solution technique. In particular, the geographically correlated orbit error is partially observable from a dataset consisting of crossover differences between two sufficiently different altimetry datasets, while being unobservable from the analysis of altimetry data of both satellites individually. This error signal, which has a substantial gravity-induced component, can be employed advantageously in simultaneous solutions for the two satellites in which also the harmonic coefficients of the gravity field model are estimated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Satellite information, in combination with conventional point source measurements, can be a valuable source of information. This thesis is devoted to the spatial estimation of areal rainfall over a region using both the measurements from a dense and sparse network of rain-gauges and images from the meteorological satellites. A primary concern is to study the effects of such satellite assisted rainfall estimates on the performance of rainfall-runoff models. Low-cost image processing systems and peripherals are used to process and manipulate the data. Both secondary as well as primary satellite images were used for analysis. The secondary data was obtained from the in-house satellite receiver and the primary data was obtained from an outside source. Ground truth data was obtained from the local Water Authority. A number of algorithms are presented that combine the satellite and conventional data sources to produce areal rainfall estimates and the results are compared with some of the more traditional methodologies. The results indicate that the satellite cloud information is valuable in the assessment of the spatial distribution of areal rainfall, for both half-hourly as well as daily estimates of rainfall. It is also demonstrated how the performance of the simple multiple regression rainfall-runoff model is improved when satellite cloud information is used as a separate input in addition to rainfall estimates from conventional means. The use of low-cost equipment, from image processing systems to satellite imagery, makes it possible for developing countries to introduce such systems in areas where the benefits are greatest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method of accurately controlling the position of a mobile robot using an external large volume metrology (LVM) instrument is presented in this article. By utilising an LVM instrument such as a laser tracker or indoor GPS (iGPS) in mobile robot navigation, many of the most difficult problems in mobile robot navigation can be simplified or avoided. Using the real-time position information from the laser tracker, a very simple navigation algorithm, and a low cost robot, 5mm repeatability was achieved over a volume of 30m radius. A surface digitisation scan of a wind turbine blade section was also demonstrated, illustrating possible applications of the method for manufacturing processes. Further, iGPS guidance of a small KUKA omni-directional robot has been demonstrated, and a full scale prototype system is being developed in cooperation with KUKA Robotics, UK. © 2011 Taylor & Francis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Hospital discharge is a transition of care, where medication discrepancies are likely to occur and potentially cause patient harm. The purpose of our study was to assess the prescribing accuracy of hospital discharge medication orders at a London, UK teaching hospital. The timeliness of the discharge summary reaching the general practitioner (GP, family physician) was also assessed based on the 72 h target referenced in the Care Quality Commission report.1 Method: 501 consecutive discharge medication orders from 142 patients were examined and the following records were compared (1) the final inpatient drug chart at the point of discharge, (2) printed signed copy of the initial to take away (TTA) discharge summary produced electronically by the physician, (3) the pharmacist's amendments on the initial TTA that were hand written, (4) the final electronic patient discharge summary record, (5) the patients final take home medication from the hospital. Discrepancies between the physician's order (6) and pharmacist's change(s) (7) were compared with two types of failures – ‘failure to make a required change’ and ‘change where none was required’. Once the patient was discharged, the patient's GP, was contacted 72 h after discharge to see if the patient discharge summary, sent by post or via email, was received. Results: Over half the patients seen (73 out of 142) patients had at least one discrepancy that was made on the initial TTA by the doctor and amended by the pharmacist. Out of the 501 drugs, there were 140 discrepancies, 108 were ‘failures to make a required change’ (77%) and 32 were ‘changes where none were required’ (23%). The types of ‘failures to make required changes’ discrepancies that were found between the initial TTA and pharmacist's amendments were paracetamol and ibuprofen changes (dose banding) 38 (27%), directions of use 34 (24%), incorrect formulation of medication 28 (20%) and incorrect strength 8 (6%). The types of ‘changes where none were required discrepancies’ were omitted medication 15 (11%), unnecessary drug 14 (10%) and incorrect medicine including spelling mistakes 3 (2%). After contacting the GPs of the discharged patients 72 h postdischarge; 49% had received the discharge summary and 45% had not, the remaining 6% were patients who were discharged without a GP. Conclusion: This study shows that doctor prescribing at discharge is often not accurate, and interventions made by pharmacist to reconcile are important at this point of care. It was also found that half the discharge summaries had not reached the patient's family physician (according to the GP) within 72 h.