28 resultados para G METHOD

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, we introduced a new 'GLM-beamformer' technique for MEG analysis that enables accurate localisation of both phase-locked and non-phase-locked neuromagnetic effects, and their representation as statistical parametric maps (SPMs). This provides a useful framework for comparison of the full range of MEG responses with fMRI BOLD results. This paper reports a 'proof of principle' study using a simple visual paradigm (static checkerboard). The five subjects each underwent both MEG and fMRI paradigms. We demonstrate, for the first time, the presence of a sustained (DC) field in the visual cortex, and its co-localisation with the visual BOLD response. The GLM-beamformer analysis method is also used to investigate the main non-phase-locked oscillatory effects: an event-related desynchronisation (ERD) in the alpha band (8-13 Hz) and an event-related synchronisation (ERS) in the gamma band (55-70 Hz). We show, using SPMs and virtual electrode traces, the spatio-temporal covariance of these effects with the visual BOLD response. Comparisons between MEG and fMRI data sets generally focus on the relationship between the BOLD response and the transient evoked response. Here, we show that the stationary field and changes in oscillatory power are also important contributors to the BOLD response, and should be included in future studies on the relationship between neuronal activation and the haemodynamic response. © 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrix application continues to be a critical step in sample preparation for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI). Imaging of small molecules such as drugs and metabolites is particularly problematic because the commonly used washing steps to remove salts are usually omitted as they may also remove the analyte, and analyte spreading is more likely with conventional wet matrix application methods. We have developed a method which uses the application of matrix as a dry, finely divided powder, here referred to as dry matrix application, for the imaging of drug compounds. This appears to offer a complementary method to wet matrix application for the MALDI-MSI of small molecules, with the alternative matrix application techniques producing different ion profiles, and allows the visualization of compounds not observed using wet matrix application methods. We demonstrate its value in imaging clozapine from rat kidney and 4-bromophenyl-1,4-diazabicyclo(3.2.2)nonane-4-carboxylic acid from rat brain. In addition, exposure of the dry matrix coated sample to a saturated moist atmosphere appears to enhance the visualization of a different set of molecules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present, for the first time to our knowledge, experimental evidence showing that superimposed blazed fiber Bragg gratings may be fabricated and used to extend the dynamic range of a grating-based spectrometer. Blazed gratings of 4° and 8° were superimposed in germanosilicate fiber by ultraviolet inscription and used in conjunction with a coated charged-coupled device array to interrogate a wavelength-division-multiplexing sensor array. We show that the system can be used to monitor strain and temperature sensors simultaneously with an employable bandwidth which is extendable to 70 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantum dots (Qdots) are fluorescent nanoparticles that have great potential as detection agents in biological applications. Their optical properties, including photostability and narrow, symmetrical emission bands with large Stokes shifts, and the potential for multiplexing of many different colours, give them significant advantages over traditionally used fluorescent dyes. Here, we report the straightforward generation of stable, covalent quantum dot-protein A/G bioconjugates that will be able to bind to almost any IgG antibody, and therefore can be used in many applications. An additional advantage is that the requirement for a secondary antibody is removed, simplifying experimental design. To demonstrate their use, we show their application in multiplexed western blotting. The sensitivity of Qdot conjugates is found to be superior to fluorescent dyes, and comparable to, or potentially better than, enhanced chemiluminescence. We show a true biological validation using a four-colour multiplexed western blot against a complex cell lysate background, and have significantly improved previously reported non-specific binding of the Qdots to cellular proteins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first part of the thesis compares Roth's method with other methods, in particular the method of separation of variables and the finite cosine transform method, for solving certain elliptic partial differential equations arising in practice. In particular we consider the solution of steady state problems associated with insulated conductors in rectangular slots. Roth's method has two main disadvantages namely the slow rate of con­vergence of the double Fourier series and the restrictive form of the allowable boundary conditions. A combined Roth-separation of variables method is derived to remove the restrictions on the form of the boundary conditions and various Chebyshev approximations are used to try to improve the rate of convergence of the series. All the techniques are then applied to the Neumann problem arising from balanced rectangular windings in a transformer window. Roth's method is then extended to deal with problems other than those resulting from static fields. First we consider a rectangular insulated conductor in a rectangular slot when the current is varying sinusoidally with time. An approximate method is also developed and compared with the exact method.The approximation is then used to consider the problem of an insulated conductor in a slot facing an air gap. We also consider the exact method applied to the determination of the eddy-current loss produced in an isolated rectangular conductor by a transverse magnetic field varying sinusoidally with time. The results obtained using Roth's method are critically compared with those obtained by other authors using different methods. The final part of the thesis investigates further the application of Chebyshdev methods to the solution of elliptic partial differential equations; an area where Chebyshev approximations have rarely been used. A poisson equation with a polynomial term is treated first followed by a slot problem in cylindrical geometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Renewable energy project development is highly complex and success is by no means guaranteed. Decisions are often made with approximate or uncertain information yet the current methods employed by decision-makers do not necessarily accommodate this. Levelised energy costs (LEC) are one such commonly applied measure utilised within the energy industry to assess the viability of potential projects and inform policy. The research proposes a method for achieving this by enhancing the traditional discounting LEC measure with fuzzy set theory. Furthermore, the research develops the fuzzy LEC (F-LEC) methodology to incorporate the cost of financing a project from debt and equity sources. Applied to an example bioenergy project, the research demonstrates the benefit of incorporating fuzziness for project viability, optimal capital structure and key variable sensitivity analysis decision-making. The proposed method contributes by incorporating uncertain and approximate information to the widely utilised LEC measure and by being applicable to a wide range of energy project viability decisions. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Kozlov & Maz'ya (1989, Algebra Anal., 1, 144–170) proposed an alternating iterative method for solving Cauchy problems for general strongly elliptic and formally self-adjoint systems. However, in many applied problems, operators appear that do not satisfy these requirements, e.g. Helmholtz-type operators. Therefore, in this study, an alternating procedure for solving Cauchy problems for self-adjoint non-coercive elliptic operators of second order is presented. A convergence proof of this procedure is given.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present, for the first time to our knowledge, experimental evidence showing that superimposed blazed fiber Bragg gratings may be fabricated and used to extend the dynamic range of a grating-based spectrometer. Blazed gratings of 4° and 8° were superimposed in germanosilicate fiber by ultraviolet inscription and used in conjunction with a coated charged-coupled device array to interrogate a wavelength-division-multiplexing sensor array. We show that the system can be used to monitor strain and temperature sensors simultaneously with an employable bandwidth which is extendedable to 70 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Development and validation of a selective and sensitive LCMS method for the determination of methotrexate polyglutamates in dried blood spots (DBS). Methods: DBS samples [spiked or patient samples] were prepared by applying blood to Guthrie cards which was then dried at room temperature. The method utilised 6-mm disks punched from the DBS samples (equivalent to approximately 12 μl of whole blood). The simple treatment procedure was based on protein precipitation using perchloric acid followed by solid phase extraction using MAX cartridges. The extracted sample was chromatographed using a reversed phase system involving an Atlantis T3-C18 column (3 μm, 2.1x150 mm) preceded by Atlantis guard column of matching chemistry. Analytes were subjected to LCMS analysis using positive electrospray ionization. Key Results: The method was linear over the range 5-400 nmol/L. The limits of detection and quantification were 1.6 and 5 nmol/L for individual polyglutamates and 1.5 and 4.5 nmol/L for total polyglutamates, respectively. The method has been applied successfully to the determination of DBS finger-prick samples from 47 paediatric patients and results confirmed with concentrations measured in matched RBC samples using conventional HPLC-UV technique. Conclusions and Clinical Relevance: The methodology has a potential for application in a range of clinical studies (e.g. pharmacokinetic evaluations or medication adherence assessment) since it is minimally invasive and easy to perform, potentially allowing parents to take blood samples at home. The feasibility of using DBS sampling can be of major value for future clinical trials or clinical care in paediatric rheumatology. © 2014 Hawwa et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6 mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r ≥ 0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1 μg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were <20% at the LLOQs and <15% at all other concentrations tested. This method was successfully applied to the analysis of the AEDs in DBS samples taken from children with epilepsy for the assessment of their adherence to prescribed treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An alternating procedure for solving a Cauchy problem for the stationary Stokes system is presented. A convergence proof of this procedure and numerical results are included.