Resumo:
Purpose: To investigate the correlation between tests of visual function and perceived visual ability recorded with a 'quality-of-life' questionnaire for patients with central field loss. Method: 12 females and 7 males (mean age = 53.1 years; Range = 23 - 80 years) with subfoveal neovascular membranes underwent a comprehensive assessment of visual function. Tests included unaided distance vision, high and low contrast distance logMAR visual acuity (VA), Pelli-Robson contrast senstivity (at 1m), near logMAR word VA and text reading speed. All tests were done both monocularly and binocularly. The patients also completed a 28 point questionnaire separated into a 'core' section consisting of general questions about perceived visual function and a 'module' section with specific questions on reading function. Results: Step-wise multiple regression analysis was used to determine which visual function tests were correlated with the patients's perceived visual function and to rank them in order of importance. The visual function test that explains most of the variance in both 'core' score (66%0 and the 'module' score (68%) of the questionnaire is low contrast VA in the better eye (P<0.001 in both cases). Further, the module score also accounts for a significant proportion of the variance (P<0.01) of the distance logMAR VA in both the better and worse eye, and the near logMAR in both the better eye and binocularly. Conclusions: The best predictor of both perceived reading ability and of general perceived visual ability in this study is low contrast logMAR VA. The results highlight that distance VA is not the only relevant measure of visual fucntion in relation to a patients's perceived visual performance and should not be considered a determinant of surgical or management success.
Resumo:
Context: Subclinical hypothyroidism (SCH) and cognitive dysfunction are both common in the elderly and have been linked. It is important to determine whether T4 replacement therapy in SCH confers cognitive benefit. Objective: Our objective was to determine whether administration of T4 replacement to achieve biochemical euthyroidism in subjects with SCH improves cognitive function. Design and Setting: We conducted a double-blind placebo-controlled randomized controlled trial in the context of United Kingdom primary care. Patients: Ninety-four subjects aged 65 yr and over (57 females, 37 males) with SCH were recruited from a population of 147 identified by screening. Intervention: T4 or placebo was given at an initial dosage of one tablet of either placebo or 25 µg T4 per day for 12 months. Thyroid function tests were performed at 8-weekly intervals with dosage adjusted in one-tablet increments to achieve TSH within the reference range for subjects in treatment arm. Fifty-two subjects received T4 (31 females, 21 males; mean age 73.5 yr, range 65–94 yr); 42 subjects received placebo (26 females, 16 males; mean age 74.2 yr, 66–84 yr). Main Outcome Measures: Mini-Mental State Examination, Middlesex Elderly Assessment of Mental State (covering orientation, learning, memory, numeracy, perception, attention, and language skills), and Trail-Making A and B were administered. Results: Eighty-two percent and 84% in the T4 group achieved euthyroidism at 6- and 12-month intervals, respectively. Cognitive function scores at baseline and 6 and 12 months were as follows: Mini-Mental State Examination T4 group, 28.26, 28.9, and 28.28, and placebo group, 28.17, 27.82, and 28.25 [not significant (NS)]; Middlesex Elderly Assessment of Mental State T4 group, 11.72, 11.67, and 11.78, and placebo group, 11.21, 11.47, and 11.44 (NS); Trail-Making A T4 group, 45.72, 47.65, and 44.52, and placebo group, 50.29, 49.00, and 46.97 (NS); and Trail-Making B T4 group, 110.57, 106.61, and 96.67, and placebo group, 131.46, 119.13, and 108.38 (NS). Linear mixed-model analysis demonstrated no significant changes in any of the measures of cognitive function over time and no between-group difference in cognitive scores at 6 and 12 months. Conclusions: This RCT provides no evidence for treating elderly subjects with SCH with T4 replacement therapy to improve cognitive function.
Resumo:
Aims: Oestrogens are known to act on a number of tissues throughout the body via classical oestrogen receptors, alpha (ER-a) and beta (ER-beta). Previous research has shown that oestrogens can regulate skeletal muscle glucose uptake cellular proliferation. Thus, oestrogens and related molecules provide an interesting focus for research into possible therapies for the treatment of metabolic disorders and sarcopenia. Enterodiol and enterolactone are plant derived mammalian enterolignans which share a struc- tural similarity to the human oestrogen oestradiol. Methods: In the present study we incubated the differentiated rat skeletal muscle cell line L6 concentration ranges of both com- pounds in the presence/absence of oestrogen receptor antagonists and measured glucose uptake using the non-metabolised glucose analogue 2-NBDG. Cellular proliferation was also measured using a modified MTS assay. Results: Enterolactone was seen to cause a significant increase in cellular proliferation after 48h (a maximal 25% at 0.1nmol/l), in an ER-a dependent mechanism. Incubation with 10nmol/l and 100nmol/l enterodiol caused significant increases in 2-NBDG (5000% compared with control, p < 0.001) and 2h glucose depletion from media (15% increase compared with control, p < 0.05), also in an ER-a dependent way. These results suggest these dietary derived oestrogen-like molecules might be of potential use in targeting metabolic disorders or sarcopenia. Conclusion: We can report here that the phytoestrogen derived molecules enterodiol and enterolactone interact with ER-a in the myotubes to regulate glucose uptake and cellular proliferation respectively.
Resumo:
Background: The aim was to investigate the visual effect of coloured filters compared to transmission-matched neutral density filters, in patients with dry age-related macular degeneration. Methods: Visual acuity (VA, logMAR), contrast sensitivity (Pelli-Robson) and colour vision (D15) were recorded for 39 patients (average age 79.1 ± 7.2 years) with age-related macular degeneration, both in the presence and absence of glare from a fluorescent source. Patients then chose their preferred coloured and matched neutral density transmission filters (NoIR). Visual function tests were repeated with the chosen filters, both in the presence and absence of glare from the fluorescent source. Patients trialled the two filters for two weeks each, in random order. Following the trial of each filter, a telephone questionnaire was completed. Results: VA and contrast sensitivity were unaffected by the coloured filters but reduced through the neutral density filters (p < 0.01). VA and contrast sensitivity were reduced by similar amounts, following the introduction of the glare source, both in the presence and absence of filters (p < 0.001). Colour vision error scores were increased following the introduction of a neutral density filter (from 177.6 ± 60.2 to 251.9 ± 115.2) and still further through coloured filters (275.1 ± 50.8; p < 0.001). In the absence of any filter, colour vision error scores increased by 29.1 ± 55.60 units in the presence of glare (F2,107 = 3.9, p = 0.02); however, there was little change in colour vision error scores, in the presence of glare, with either the neutral density or coloured filters. Questionnaires indicated that patients tended to gain more benefit from the coloured filters. Conclusions: Coloured filters had minimal impact on VA and contrast sensitivity in patients with age-related macular degeneration; however, they caused a small reduction in objective colour vision, although this was not registered subjectively by patients. Patients indicated that they received more benefit from the coloured filters compared with neutral density filters. © 2013 The Authors © 2013 Optometrists Association Australia.
Resumo:
Background: Coronary heart disease patients have to learn to manage their condition to maximise quality of life and prevent recurrence or deterioration. They may develop their own informal methods of self-management in addition to the advice they receive as part of formal cardiac rehabilitation programmes. This study aimed to explore the use of complementary and alternative medicines and therapies (CAM), self-test kits and attitudes towards health of UK patients one year after referral to cardiac rehabilitation. Method: Questionnaire given to 463 patients attending an assessment clinic for 12 month follow up in four West Midlands hospitals. Results: 91.1% completed a questionnaire. 29.1% of patients used CAM and/or self-test kits for self-management but few (8.9%) used both methods. CAM was more often used for treating other illnesses than for CHD management. Self-test kit use (77.2%,) was more common than CAM (31.7%,) with BP monitors being the most prevalent (80.0%). Patients obtained self-test kits from a wide range of sources, for the most part (89.5%) purchased entirely on their own initiative. Predictors of self-management were post revascularisation status and higher scores on 'holism', 'rejection of authority' and 'individual responsibility'. Predictors of self-test kit use were higher `holism' and 'individual responsibility' scores. Conclusion: Patients are independently using new technologies to monitor their cardiovascular health, a role formerly carried out only by healthcare practitioners. Post-rehabilitation patients reported using CAM for self-management less frequently than they reported using self-test kits. Reports of CAM use were less frequent than in previous surveys of similar patient groups. Automatic assumptions cannot be made by clinicians about which CHD patients are most likely to self-manage. In order to increase trust and compliance it is important for doctors to encourage all CHD patients to disclose their self-management practices and to continue to address this in follow up consultations.
Resumo:
Redox-sensitive cell signalling Thiol groups and the regulation of gene expression Redox-sensitive signal transduction pathways Protein kinases Protein phosphatases Lipids and phospholipases Antioxidant (electrophile) response element Intracellular calcium signalling Transcription factors NF-?B AP-1 p53 Cellular responses to oxidative stress Cellular responses to change in redox state Proliferation Cell death Immune cell function Reactive oxygen and nitrogen species – good or bad? Reactive oxygen species and cell death Reactive oxygen species and inflammation Are specific reactive oxygen species and antioxidants involved in modulating cellular responses? Specific effects of dietary antioxidants in cell regulation Carotenoids Vitamin E Flavonoids Inducers of phase II enzymes Disease states affected Oxidants, antioxidants and mitochondria Introduction Mitochondrial generation of reactive oxygen and nitrogen species Mitochondria and apoptosis Mitochondria and antioxidant defences Key role of mitochondrial GSH in the defence against oxidative damage Mitochondrial oxidative damage Direct oxidative damage to the mitochondrial electron transport chain Nitric oxide and damage to mitochondria Effects of nutrients on mitochondria Caloric restriction and antioxidants Lipids Antioxidants Techniques and approaches Mitochondrial techniques cDNA microarray approaches Proteomics approaches Transgenic mice as tools in antioxidant research Gene knockout and over expression Transgenic reporter mice Conclusions Future research needs
Resumo:
Aim: To investigate the correlation between tests of visual function and perceived visual ability recorded with a quality of life questionnaire for patients with uveitis. Methods: 132 patients with various types of uveitis were studied. High (monocular and binocular) and low (binocular) contrast logMAR letter acuities were recorded using a Bailey-Lovie chart. Contrast sensitivity (binocular) was determined using a Pelli-Robson chart. Vision related quality of life was assessed using the Vision Specific Quality of Life (VQOL) questionnaire. Results: VQOL declined with reduced performance on the following tests: binocular high contrast visual acuity (p = 0.0011), high contrast visual acuity of the better eye (p = 0.0012), contrast sensitivity (p = 0.005), binocular low contrast visual acuity (p = 0.0065), and high contrast visual acuity of the worse eye (p = 0.015). Stepwise multiple regression analysis revealed binocular high contrast visual acuity (p <0.01) to be the only visual function adequate to predict VQOL. The age of the patient was also significantly associated with perceived visual ability (p <0.001). Conclusions: Binocular high contrast visual acuity is a good measure of how uveitis patients perform in real life situations. Vision quality of life is worst in younger patients with poor binocular visual acuity.
Resumo:
PURPOSE: To determine the objective measures of visual function that are most relevant to subjective quality of vision and perceived reading ability in patients with acquired macular disease. METHODS: Twenty-eight patients with macular disease underwent a comprehensive assessment of visual function. The patients also completed a vision-related quality-of-life questionnaire that included a section of general questions about perceived visual performance and a section with specific questions on reading. RESULTS: Results of all tests of vision correlated highly with reported vision-related quality-of-life impairment. Low-contrast tests explained most of the variance in self-reported problems with reading. Text-reading speed correlated highly with overall concern about vision. CONCLUSIONS: Reading performance is strongly associated with vision-related quality of life. High-contrast distance acuity is not the only relevant measure of visual function in relation to the perceived visual performance of a patient with macular disease. The results suggest the importance of print contrast, even over print size, in reading performance in patients with acquired macular disease.
Resumo:
Programmed cell death, apoptosis, is a highly regulated process that removes damaged or unwanted cells in vivo and has significant immunological implications. Defective clearance of apoptotic cells by macrophages (professional phagocytes) is known to result in chronic inflammatory and autoimmune disease. Tissue transglutaminase 2 (TG2) is a Ca2+-dependent protein cross linking enzyme known to play an important role in a number of cell functions. Up-regulation of TG2 is thought to be involved in monocyte to macrophage differentiation and defective clearance of apoptotic cells by TG2 null mice has been described though in this context the role of TG2 is yet to be fully elucidated. Cell surface-associated TG2 is now recognized as being important in regulating cell adhesion and migration, via its association with cell surface receptors such as syndecan-4, ß1 and ß3 integrin, but its extracellular role in the clearance of apoptotic cells is still not fully explored. Our work aims to characterize the role of TG2 and its partners (e.g. syndecan-4 and ß3 integrin) in macrophage function within the framework of apoptotic cell clearance. Both THP-1 cell-derived macrophage-like cells and primary human macrophages were analyzed for the expression and function of TG2. Macrophage-apoptotic cell interaction studies in the presence of TG2 inhibitors (both cell permeable and impermeable, irreversible and active site directed) resulted in significant inhibition of interaction indicating a possible role for TG2 in apoptotic cell clearance. Macrophage cell surface TG2 and, in particular, its cell surface crosslinking activity was found to be crucial in dictating apoptotic cell clearance. Our further studies demonstrate syndecan-4 association with TG2 and imply possible cooperation of these proteins in apoptotic cell clearance. Knockdown studies of syndecan-4 reveal its importance in apoptotic cell clearance. Our current findings suggest that TG2 has a crucial but yet to be fully defined role in apoptotic cell clearance which seems to involve protein cross linking and interaction with other cell surface receptors.
Resumo:
Autism is a pervasive developmental disorder and Asperger’s syndrome is part of the spectrum of autism disorders. This thesis aims to: • Review and investigate current theories concerning visual function in individuals with Asperger’s syndrome and high functioning autism spectrum disorder and to translate the findings into clinical practice by developing a specific protocol for the eye examination of individuals of this population. • Investigate whether those with Asperger’s syndrome are more likely to suffer from Meares-Irlen syndrome and/or dyslexia. • Assess the integrity of the M-cell pathway in Asperger’s syndrome using perimetric tests available in optometric practice to investigate and also to describe the nature of any defects. • Evaluate eye movement strategies in Asperger’s whilst viewing both text and images. Also to evaluate the most appropriate methodology for investigating eye movements; namely optical digital eye tracking and electrophysiology methodologies. Findings of the investigations include • Eye examinations for individuals with Asperger’s syndrome should contain the same testing methods as for the general population, with special consideration for clear communication. • There is a depression of M-pathway visual field sensitivity in 57% (8/14) of people with Asperger’s syndrome, supporting previous evidence for an M-cell deficit in some individuals. • There is a raised prevalence of dyslexia in Asperger’s syndrome (26% of a sample of 31) but not necessarily of Meares-Irlen syndrome. • Gaze strategies are abnormal in Asperger’s syndrome, for both reading and viewing of images. With increased saccadic movement and decreased viewing of faces in comparison to background detail.
Resumo:
Intraocular light scatter is high in certain subject groups eg the elderly, due to increased optical media turbidity, which scatters and attenuates light travelling towards the retina. This causes reduced retinal contrast especially in the presence of glare light. Such subjects have depressed Contrast Sensitivity Functions (CSF). Currently available clinical tests do not effectively reflect this visual disability. Intraocular light scatter may be quantified by measuring the CSF with and without glare light and calculating Light Scatter Factors (LSF). To record the CSF on clinically available equipment (Nicolet CS2000), several psychophysical measurement techniques were investigated, and the 60 sec Method of Increasing Contrast was selected as the most appropriate. It was hypothesised that intraocular light scatter due to particles of different dimensions could be identified by glare sources at wide (30°) and narrow (3.5°) angles. CSFs andLSFs were determined for: (i) Subjects in young, intermediate and old age groups. (ii) Subjects during recovery from large amounts of induced corneal oedema. (iii) A clinical sample of contact lens (CL) wearers with a group of matched controls. The CSF was attenuated at all measured spatial frequencies with the intermediate and old group compared to the young group. High LSF values were found only in the old group (over 60 years). It was concluded that CSF attenuation in the intermediate group was due to reduced pupil size, media absorption and/or neural factors. In the old group, the additional factor was high intraocular light scatter levels of lenticular origin. The rate of reduction of the LSF for the 3.5° glare angle was steeper than that for the 30° angle, following induced corneal oedema. This supported the hypothesis, as it was anticipated that epithelial oedema would recover more rapidly than stromal oedema. CSFs and LSFs were markedly abnormal in the CL wearers. The analytical details and the value of these investigative techniques in contact lens research are discussed.
Resumo:
Silicone elastomers are commonly used in the manufacture of single-piece joint replacement implants for the finger joints. However, the survivorship of these implants can be poor, with failure typically occurring from fracture of the stems. The aim of this paper was to investigate the crack growth of medical-grade silicone using pure shear tests. Two medical-grade silicones (C6-180 and Med82-5010-80) were tested. Each sample had a 20 mm crack introduced and was subjected to a sinusoidally varying tensile strain, with a minimum of 0 per cent and a maximum in the range 10 to 77 per cent. Testing was undertaken at a frequency of 10 Hz. At various times during testing, the testing machine was stopped, the number of cycles completed was noted, and the crack length measured. Graphs of crack length against number of cycles were plotted, as well as the crack growth rate against tearing energy. The results show that Med82-5010-80 is more crack resistant than C6-180. Graphs of crack growth rate against tearing energy can be used to predict the failure of these medical-grade elastomers.