37 resultados para Fuel pumps

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the more important parameters of the heat pump system and of solar assisted heat pump systems were analysed in a quantitative way. Ideal and real Rankine cycles applied to the heat pump, with and without subcooling and superheating were studied using practical recommended values for their thermodynamics parameters. Comparative characteristics of refrigerants here analysed looking for their applicability in heat pumps for domestic heating and their effect in the performance of the system. Curves for the variation of the coefficient of performance as a function of condensing and evaporating temperatures were prepared for R12. Air, water and earth as low-grade heat sources and basic heat pump design factors for integrated heat pumps and thermal stores and for solar assisted heat pump-series, parallel and dual-systems were studied. The analysis of the relative performance of these systems demonstrated that the dual system presents advantages in domestic applications. An account of energy requirements for space and hater heating in the domestic sector in the O.K. is presented. The expected primary energy savings by using heat pumps to provide for the heating demand of the domestic sector was found to be of the order of 7%. The availability of solar energy in the U.K. climatic conditions and the characteristics of the solar radiation here studied. Tables and graphical representations in order to calculate the incident solar radiation over a tilted roof were prepared and are given in this study in section IV. In order to analyse and calculate the heating load for the system, new mathematical and graphical relations were developed in section V. A domestic space and water heating system is described and studied. It comprises three main components: a solar radiation absorber, the normal roof of a house, a split heat pump and a thermal store. A mathematical study of the heat exchange characteristics in the roof structure was done. This permits to evaluate the energy collected by the roof acting as a radiation absorber and its efficiency. An indication of the relative contributions from the three low-grade sources: ambient air, solar boost and heat loss from the house to the roof space during operation is given in section VI, together with the average seasonal performance and the energy saving for a prototype system tested at the University of Aston. The seasonal performance as found to be 2.6 and the energy savings by using the system studied 61%. A new store configuration to reduce wasted heat losses is also discussed in section VI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rolls-Royce fuel cell systems is developing megawatt scale power systems based on solid oxide fuel cell technology. The hybrid design promises to meet challenging energy efficiency, cost and performance targets in a grid friendly fashion. Analysis and testing to date indicate that those targets can be met and enable a wealth of fuel cell applications to meet customer and existing grid and modern grid requirements. Working with a global development team, a series of laboratory tests and evaluations are completed and future field test and evaluation and demonstration planned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead in petrol has been identified as a health hazard and attempts are being made to create a lead-free atmosphere. Through an intensive study a review is made of the various options available to the automobile and petroleum industry. The economic and atmospheric penalties coupled with automobile fuel consumption trends are calculated and presented in both graphical and tabulated form. Experimental measurements of carbon monoxide and hydrocarbon emissions are also presented for certain selected fuels. Reduction in CO and HC's with the employment of a three-way catalyst is also discussed. All tests were carried out on a Fiat 127A engine at wide open throttle and standard timing setting. A Froude dynamometer was used to vary engine speed. With the introduction of lead-free petrol, interest in combustion chamber deposits in spark ignition engines has ben renewed. These deposits cause octane requirement increase or rise in engine knock and decreased volumetric efficiency. The detrimental effect of the deposits has been attributed to the physical volume of the deposit and to changes in heat transfer. This study attempts to assess why leaded deposits, though often greater in mass and volume, yield relatively lower ORI when compared to lead-free deposits under identical operating conditions. This has been carried out by identifying the differences in the physical nature of the deposit and then through measurement of the thermal conductivity and permeability of the deposits. The measured thermal conductivity results are later used in a mathematical model to determine heat transfer rates and temperature variation across the engine wall and deposit. For the model, the walls of the combustion cylinder and top are assumed to be free of engine deposit, the major deposit being on the piston head. Seven different heat transfer equations are formulated describing heat flow at each part of the four stroke cycle, and the variation of cylinder wall area exposed to gas mixture is accounted for. The heat transfer equations are solved using numerical methods and temperature variations across the wall identified. Though the calculations have been carried out for one particular moment in the cycle, similar calculations are possible for every degree of the crank angle, and thus further information regarding location of maximum temperatures at every degree of the crank angle may also be determined. In conclusion, thermal conductivity values of leaded and lead-free deposits have been found. The fundamental concepts of a mathematical model with great potential have been formulated and it is hoped that with future work it may be used in a simulation for different engine construction materials and motor fuels, leading to better design of future prototype engines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the oil crisis of 1973 considerable interest has been shown in the production of liquid fuels from alternative sources. In particular processes utilizing coal as the feedstock have received considerable interest. These processes can be divided into direct and indirect liquefaction and pyrolysis. This thesis describes the modelling of indirect coal liquefaction processes for the purpose of performing technical and economic assessment of the production of liquid fuels from coal and lignite, using a variety of gasification and synthesis gas liquefaction technologies. The technologies were modeled on a 'step model' basis where a step is defined as a combination of individual unit operations which together perform a significant function on the process streams, such as a methanol synthesis step or a gasification and physical gas cleaning step. Sample results of the modelling, covering a wide range of gasifiers, liquid synthesis processes and products are presented in this thesis. Due to the large number of combinations of gasifier, liquid synthesis processes, products and economic sensitivity cases, a complete set of results is impractical to present in a single publication. The main results show that methanol is the cheapest fuel to produce from coal followed by fuel alcohol, diesel from the Shell Middle Distillate Synthesis process,gasoline from Mobil Methanol to Gasoline (MTG) process, diesel from the Mobil Methanol Olefins Gasoline Diesel (MOGD) process and finally gasoline from the same process. Some variation in production costs of all the products was shown depending on type of gasifier chosen and feedstock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the investigation was to study the problem of colonization of shipboard fuel systems and to examine the effect of a number of environmental factors on microbial growth and survival in order to find potential preservative treatments. A variety of microbial species were isolated from samples taken from fuel storage tanks. Bacteria were more numerous than yeasts or fungi and most microorganisms were found at the fuel/water interface. 1he salinity, pH and phosphate concentration of some water bottoms were characteristic of sea water. Others were brackish, acidic and varied in phosphate content. Microorganisms were cultured under a number of environmental conditions. After prolonged incubation, the inoculum size had no effect on the final biomass of Cladosporium resinae but the time required to achieve the final mass decreased with increasing spore number. Undecane supported better growth of the fungus than diesel fuel and of four types of diesel fuel, two allowed more profuse growth. With sea water as the aqueous phase, a number of isolates were inhibited but the addition of nutrients allowed the development of many of the organisms. Agitation increased the growth of C. resinae on glucose but inhibited it on hydrocarbons. The optimum temperature fgr growth of C. resinae on surface culture lay between 25º C and 30º C and growth was evident at 5º C but not at 45º C. In aqueous suspension, 90% of spores were inactivated in around 60 hours at 45ºC and the same proportion of spores of C. resinae and Penicillium corylophilum were destroyed after about 30 seconds at 65ºC. The majority of bacteria and all yeasts in a water bottom sample were killed within 10 seconds at this temperature. An increase in the concentration of an organo-boron compound caused more rapid inactivation of C. resinae spores and raising the temperature from 25ºC to 45°C significantly enhanced the potency of the biocide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents a study of the chemical reactions that may occur at the fuel- clad interfaces of fuel elements used in advanced gas-coooled reactors (A.G.R.) The initial investigation involved a study of the inner surfaces of irradiated stainless steel clad and evidence was obtained to show that fission products, in particular tellerium, were associated with reaction products on these surfaces. An accelerated rate of oxidation was observed on the inner surfaces of a failed A.G.R. fuel pin. It is believed that fission product caesium was responsible for this enhancement. A fundamental study of the reaction between 20%Cr/25%Ni/niobium stabilised stainless steel and tellerium was then undertaken over the range 350 - 850 degrees C. Reaction occurred with increasing rapidity over this range and long term exposure at ≤ 750 degrees resulted in intergranular attack of the stainless steel and chromium depletion. The reaction on unoxidised steel surfaces involved the formation of an initial iron-nickel-tellerium layer which subsequently transformed to a chromium telluride product during continued exposure. The thermodynamic stabilities of the steel tellurides were determined to be chromium telluride > nickel telluride > iron telluride. Oxidation of the stainless steel surface prior to tellerium exposure inhibited the reaction. However reaction did occur in regions where the oxide layer had either cracked or spalled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water is a common impurity of jet fuel, and can exist in three forms: dissolved in the fuel, as a suspension and as a distinct layer at the bottom of the fuel tank. Water cannot practically be eliminated from fuel but must be kept to a minimum as large quantities can cause engine problems, particularly when frozen, and the interface between water and fuel acts as a breeding ground for biological contaminants. The quantities of dissolved or suspended water are quite small, ranging from about 10 ppm to 150 ppm. This makes the measurement task difficult and there is currently a lack of a convenient, electrically passive system for water-in-fuel monitoring; instead the airlines rely on colorimetric spot tests or simply draining liquid from the bottom of fuel tanks. For all these reason, people have explored different ways to detect water in fuel, however all these approaches have problems, e.g. they may not be electrically passive or they may be sensitive to the refractive index of the fuel. In this paper, we present a simple, direct and sensitive approach involving the use of a polymer optical fibre Bragg grating to detect water in fuel. The principle is that poly(methyl methacrylate) (PMMA) can absorb moisture from its surroundings (up to 2% at 23 °C), leading to both a swelling of the material and an increase in refractive index with a consequent increase in the Bragg wavelength of a grating inscribed in the material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fluids used in hydraulic systems inevitably contain large numbers of small, solid particles, a phenomenon known as 'fluid contamination'. Particles enter a hydraulic system from the environment, and are generated within it by processes of wear. At the same time, particles are removed from the system fluid by sedimentation and in hydraulic filters. This thesis considers the problems caused by fluid contamination, as they affect a manufacturer of axial piston pumps. The specific project aim was to investigate methods of predicting or determining the effects of fluid contamination on this type of pump. The thesis starts with a theoretical analysis of the contaminated lubrication of a slipper-pad bearing. Statistical methods are used to develop a model of the blocking, by particles, of the control capillaries used in such bearings. The results obtained are compared to published, experimental data. Poor correlation between theory and practice suggests that more research is required in this area before such theoretical analysis can be used in industry. Accelerated wear tests have been developed in the U.S.A. in an attempt to predict pump life when operating on contaminated fluids. An analysis of such tests shows that reliability data can only be obtained from extensive test programmes. The value of contamination testing is suggested to be in determining failure modes, and in identifying those pump components which are susceptible to the effects of contamination. A suitable test is described, and the results of a series of tests on axial piston pumps are presented and discussed. The thesis concludes that pump reliability data can only be obtained from field experience. The level of confidence which can be placed in results from normal laboratory testing is shown to be too low for the data to be of real value. Recommendations are therefore given for the ways in which service data should be collected and analysed.